GB/T 5023.1-2008   Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 1: General requirements (English Version)
Standard No.: GB/T 5023.1-2008 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 8000 words Price(USD):200.0 remind me the price change

Email:

Implemented on:2009-5-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 5023.1-2008
English Name: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 1: General requirements
Chinese Name: 额定电压450/750V及以下聚氯乙烯绝缘电缆 第1部分:一般要求
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Issued by: AQSIQ; SAC
Issued on: 2008-6-30
Implemented on: 2009-5-1
Status: valid
Superseding:GB 5023.1-1997 Polyvinyl chloride insulated cables with rated voltage 450/750V and below - part 1: General requirements
Language: English
File Format: PDF
Word Count: 8000 words
Price(USD): 200.0
Delivery: via email in 1 business day
1 General 1.1 Scope This part of GB/T 5023 applies to rigid and flexible cables with insulation, and sheath if any, based on polyvinyl chloride, of rated voltages U0/U up to and including 450/750 V used in power installations of nominal voltage not exceeding 450/750 V a.c. Note: For some types of flexible cables the term cord is used. The particular types of cables are specified in GB/T 5023.3, GB/T 5023.4, etc. The code designations of these types of cables are given in Appendix A. The test methods specified in Parts 1, 3, 4, etc. are given in GB/T 5023.2, GB/T 18380.12-2008 and in the relevant parts of GB/T 2951-2008. 1.2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 5023. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 11: Methods for General Application — Measurement of Thickness and Overall Dimensions — Tests for Determining the Mechanical Properties (IEC 60811-1-1:2001, IDT) GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 12: Methods for General Application — Thermal Ageing Methods (IEC 60811-1-2:1985, IDT) GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 14: Methods for General Application — Test at Low Temperature (IEC 60811-1-4:1985, IDT) GB/T 2951.21-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 21: Methods Specific to Elastomeric Compounds — Ozone Resistance, Hot Set and Mineral Oil Immersion Tests (IEC 60811-2-1:2001, IDT) GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 31: Methods Specific to PVC Compounds — Pressure Test at High Temperature — Test for Resistance to Cracking(IEC 60811-3-1:1985, IDT) GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 32: Methods Specific to PVC Compounds — Loss of Mass Test — Thermal Stability Test (IEC 60811-3-2:1985, IDT) GB/T 3956-1997 Conductors of Insulated Cables (idt IEC 60228:1978) GB/T 5023.2-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 2: Test Methods (IEC 60227-2:2003, IDT) GB/T 5023.3-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 3: Non-sheathed Cables for Fixed Wiring (IEC 60227-3:1997, IDT) GB/T 5023.4-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 4: Sheathed Cables for Fixed Wiring (IEC 60227-4:1997, IDT) GB/T 5023.5-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 5: Flexible Cables (Cords) (IEC 60227-5:2003, IDT) GB/T 18380.12-2008 Test on Electric and Optical Fibre Cables Under Fire Conditions — Part 12: Test for Vertical Flame Propagation for a Single Insulated Wire or Cable — Procedure for 1kW Pre-mixed Flame (IEC 60332-1-2:2004, IDT) IEC 173:1964 Colours of the Cores of Flexible Cables and Cords IEC 62440 Electric Cables — Guide to Use for Cables with a Rated Voltage Not Exceeding 450/750V1 2 Definitions For the purpose of this part of GB/T 5023, the following definitions shall apply. 2.1 Definitions relating to insulating and sheathing materials 2.1.1 Polyvinyl chloride compound (PVC) Combination of materials suitably selected, proportioned and treated, of which the characteristic constituent is the plastomer polyvinyl chloride or one of its copolymers. The same term also designates compounds containing both polyvinyl chloride and certain of its polymers.
GB/T 5023.1-2008 is referred in:
* CJ/T 394-2012 Electro-Magnetic Emergency Shut-off Valve for Gas
* CJ/T 394-2012 Electro-Magnetic Emergency Shut-off Valve for Gas
* GB 20044-2012 Electrical accessories—Portable residual current devices without integral overcurrent protection for household and similar use(PRCD)
* CJ/T 336-2010 Condensing domestic gas instantaneous water heaters
*GB/T 34570.2-2017 Safety for rechargeable battery packs and chargers for electric tools - Part 2: Safety for chargers
*QC/T 1023-2015 General Requirement of Traction Battery System for Electric Vehicles
*GB 9706.1-2020 Medical electrical equipment—Part 1: General requirements for basic safety and essential performance
*GB/T 36672-2018 Lithium-ion battery for electric mopeds and motorcycles
*GB/T 40013-2021 Service robot—Electrical safety requirements and test methods
*GB/T 45466-2025 Gas-fired clothes dryer
*GB 45833-2025 General safety technical requirements of electricity use for gas-burning appliance
Code of China
Standard
GB/T 5023.1-2008  Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 1: General requirements (English Version)
Standard No.GB/T 5023.1-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8000 words
Price(USD)200.0
Implemented on2009-5-1
Deliveryvia email in 1 business day
Detail of GB/T 5023.1-2008
Standard No.
GB/T 5023.1-2008
English Name
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V - Part 1: General requirements
Chinese Name
额定电压450/750V及以下聚氯乙烯绝缘电缆 第1部分:一般要求
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2008-6-30
Implemented on
2009-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 5023.1-1997 Polyvinyl chloride insulated cables with rated voltage 450/750V and below - part 1: General requirements
Language
English
File Format
PDF
Word Count
8000 words
Price(USD)
200.0
Keywords
GB/T 5023.1-2008, GB 5023.1-2008, GBT 5023.1-2008, GB/T5023.1-2008, GB/T 5023.1, GB/T5023.1, GB5023.1-2008, GB 5023.1, GB5023.1, GBT5023.1-2008, GBT 5023.1, GBT5023.1
Introduction of GB/T 5023.1-2008
1 General 1.1 Scope This part of GB/T 5023 applies to rigid and flexible cables with insulation, and sheath if any, based on polyvinyl chloride, of rated voltages U0/U up to and including 450/750 V used in power installations of nominal voltage not exceeding 450/750 V a.c. Note: For some types of flexible cables the term cord is used. The particular types of cables are specified in GB/T 5023.3, GB/T 5023.4, etc. The code designations of these types of cables are given in Appendix A. The test methods specified in Parts 1, 3, 4, etc. are given in GB/T 5023.2, GB/T 18380.12-2008 and in the relevant parts of GB/T 2951-2008. 1.2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 5023. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 11: Methods for General Application — Measurement of Thickness and Overall Dimensions — Tests for Determining the Mechanical Properties (IEC 60811-1-1:2001, IDT) GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 12: Methods for General Application — Thermal Ageing Methods (IEC 60811-1-2:1985, IDT) GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 14: Methods for General Application — Test at Low Temperature (IEC 60811-1-4:1985, IDT) GB/T 2951.21-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 21: Methods Specific to Elastomeric Compounds — Ozone Resistance, Hot Set and Mineral Oil Immersion Tests (IEC 60811-2-1:2001, IDT) GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 31: Methods Specific to PVC Compounds — Pressure Test at High Temperature — Test for Resistance to Cracking(IEC 60811-3-1:1985, IDT) GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 32: Methods Specific to PVC Compounds — Loss of Mass Test — Thermal Stability Test (IEC 60811-3-2:1985, IDT) GB/T 3956-1997 Conductors of Insulated Cables (idt IEC 60228:1978) GB/T 5023.2-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 2: Test Methods (IEC 60227-2:2003, IDT) GB/T 5023.3-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 3: Non-sheathed Cables for Fixed Wiring (IEC 60227-3:1997, IDT) GB/T 5023.4-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 4: Sheathed Cables for Fixed Wiring (IEC 60227-4:1997, IDT) GB/T 5023.5-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 5: Flexible Cables (Cords) (IEC 60227-5:2003, IDT) GB/T 18380.12-2008 Test on Electric and Optical Fibre Cables Under Fire Conditions — Part 12: Test for Vertical Flame Propagation for a Single Insulated Wire or Cable — Procedure for 1kW Pre-mixed Flame (IEC 60332-1-2:2004, IDT) IEC 173:1964 Colours of the Cores of Flexible Cables and Cords IEC 62440 Electric Cables — Guide to Use for Cables with a Rated Voltage Not Exceeding 450/750V1 2 Definitions For the purpose of this part of GB/T 5023, the following definitions shall apply. 2.1 Definitions relating to insulating and sheathing materials 2.1.1 Polyvinyl chloride compound (PVC) Combination of materials suitably selected, proportioned and treated, of which the characteristic constituent is the plastomer polyvinyl chloride or one of its copolymers. The same term also designates compounds containing both polyvinyl chloride and certain of its polymers.
Contents of GB/T 5023.1-2008
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 5023.1-2008, GB 5023.1-2008, GBT 5023.1-2008, GB/T5023.1-2008, GB/T 5023.1, GB/T5023.1, GB5023.1-2008, GB 5023.1, GB5023.1, GBT5023.1-2008, GBT 5023.1, GBT5023.1