2025-12-14 216.73.216.3
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 51129-2017
GB/T 51129-2017   Standard for assessment for prefabricated building (English Version)
Standard No.: GB/T 51129-2017 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:2018-2-1 Delivery: via email in 1 business day

→ → →

,,2018-2-1,6D1947791389385E1516945753984
Standard No.: GB/T 51129-2017
English Name: Standard for assessment for prefabricated building
Chinese Name: 装配式建筑评价标准
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD
Issued on: 2017-12-12
Implemented on: 2018-2-1
Status: valid
Superseding:GB/T 51129-2015 Standard for assessment of industrialized building
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
Foreword Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. According to the requirements of the Letter on Request on the Revision of the Assessment Standard for Industrial Buildings (JIANBIAOBIAOHAN [2016] No.164) issued by the Standards Quota Department of the Ministry of Housing and Urban-Rural Development, the Technology and Industrialization Development Center of the Ministry of Housing and Urban-Rural Development (the Housing Industrialization Promotion Center of the Ministry of Housing and Urban-Rural Development), together with relevant units, carried out the preparation of this standard. The standard preparation team has carried out extensive investigations and studies, carefully summarized the implementation and practical experience of GB/T 51129-2015 Standard for assessment of industrialized building , performed a number of special studies with reference to relevant national standards and foreign advanced standards, and prepared this standard on the basis of extensive solicitation of opinions. The main technical contents of this standard include: 1. General provisions; 2. Terms; 3. Basic requirements; 4. Prefabrication ratio calculation; 5. Assessment grading. The Ministry of Housing and Urban-Rural Development is in charge of the administration of this standard; he Technology and Industrialization Development Center of the Ministry of Housing and Urban-Rural Development is responsible for the explanation of specific technical contents. In case of any comments or suggestions during the implementation, please send them to the Technology and Industrialization Development Center of the Ministry of Housing and Urban-Rural Development (Housing Industrialization Promotion Center of the Ministry of Housing and Urban-Rural Development) (Address: 9 Sanlihe Road, Haidian District, Beijing; postcode: 100835). Standard for assessment of prefabricated building 1 General provisions 1.0.1 This standard is prepared to promote the development of prefabricated buildings and standardize the assessment of prefabricated buildings. 1.0.2 This standard is applicable to the assessment on the prefabrication degree of civil buildings. 1.0.3 This standard is applicable to the assessment on the prefabrication degree of buildings with prefabrication ratio. 1.0.4 The assessment on prefabricated buildings shall also meet the requirements of relevant current national standards in addition to this standard. 2 Terms 2.0.1 prefabricated building building made of prefabricated parts and components assembled at the construction site 2.0.2 prefabrication ratio comprehensive proportion of prefabricated parts and components adopted in main structure (above the outdoor floor of a single building), enclosure wall and inner partition wall, decoration, equipment and pipelines 2.0.3 decorated full completion of the decoration of fixed surface and installation of equipment and facilities in the building functional space meeting the basic requirements of building use function and performance 2.0.4 integrated kitchen kitchen mainly prefabricated by dry method on the construction site after design, integration and factory production of floor, ceiling, wall, cabinet, kitchen equipment and pipelines 2.0.5 integrated bathroom bathroom mainly prefabricated by dry method on the construction site after design, integration and factory production of floor, ceiling, wall, sanitary ware equipment and pipelines 3 Basic requirements 3.0.1 The calculation of prefabrication rate and the grade assessment of prefabricated buildings shall take single building as the calculation and assessment unit, and meet the following requirements: 1 Single building shall be confirmed according to the building No. of the project planning approval document; 2 When the building is composed of main building and podium, the main building and podium can be calculated and assessed according to different single buildings; 3 When the number of floors of a single building is no greater than 3 and its above-ground building area is no greater than than 500m2, a building group composed of multiple single buildings can be used as a calculation and assessment unit. 3.0.2 Assessment on prefabricated buildings shall meet the following requirements: 1 Pre-assessment should be carried out in the design stage, and the prefabrication rate shall be calculated according to the design documents; 2 The project assessment shall be carried out after the completion acceptance of the project, the prefabrication rate and assessment grade shall be calculated and determined respectively according to the completion acceptance data. 3.0.3 Prefabricated buildings shall meet the following requirements at the same time: 1 The assessment score of the main structure part is no less than 20 points; 2 The assessment score of enclosure wall and inner partition wall is no less than 10 points; 3 Full decoration is adopted; 4 The prefabrication rate is no less than 50%. 3.0.4 Prefabricated decoration should be adopted for prefabricated buildings.
Foreword i 1 General provisions 2 Terms 3 Basic requirements 4 Prefabrication rate calculation 5 Assessment grading Explanation of wording in this standard
Code of China
Standard
GB/T 51129-2017  Standard for assessment for prefabricated building (English Version)
Standard No.GB/T 51129-2017
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)250.0
Implemented on2018-2-1
Deliveryvia email in 1 business day
Detail of GB/T 51129-2017
Standard No.
GB/T 51129-2017
English Name
Standard for assessment for prefabricated building
Chinese Name
装配式建筑评价标准
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD
Issued on
2017-12-12
Implemented on
2018-2-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 51129-2015 Standard for assessment of industrialized building
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
250.0
Keywords
GB/T 51129-2017, GB 51129-2017, GBT 51129-2017, GB/T51129-2017, GB/T 51129, GB/T51129, GB51129-2017, GB 51129, GB51129, GBT51129-2017, GBT 51129, GBT51129
Introduction of GB/T 51129-2017
Foreword Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. According to the requirements of the Letter on Request on the Revision of the Assessment Standard for Industrial Buildings (JIANBIAOBIAOHAN [2016] No.164) issued by the Standards Quota Department of the Ministry of Housing and Urban-Rural Development, the Technology and Industrialization Development Center of the Ministry of Housing and Urban-Rural Development (the Housing Industrialization Promotion Center of the Ministry of Housing and Urban-Rural Development), together with relevant units, carried out the preparation of this standard. The standard preparation team has carried out extensive investigations and studies, carefully summarized the implementation and practical experience of GB/T 51129-2015 Standard for assessment of industrialized building , performed a number of special studies with reference to relevant national standards and foreign advanced standards, and prepared this standard on the basis of extensive solicitation of opinions. The main technical contents of this standard include: 1. General provisions; 2. Terms; 3. Basic requirements; 4. Prefabrication ratio calculation; 5. Assessment grading. The Ministry of Housing and Urban-Rural Development is in charge of the administration of this standard; he Technology and Industrialization Development Center of the Ministry of Housing and Urban-Rural Development is responsible for the explanation of specific technical contents. In case of any comments or suggestions during the implementation, please send them to the Technology and Industrialization Development Center of the Ministry of Housing and Urban-Rural Development (Housing Industrialization Promotion Center of the Ministry of Housing and Urban-Rural Development) (Address: 9 Sanlihe Road, Haidian District, Beijing; postcode: 100835). Standard for assessment of prefabricated building 1 General provisions 1.0.1 This standard is prepared to promote the development of prefabricated buildings and standardize the assessment of prefabricated buildings. 1.0.2 This standard is applicable to the assessment on the prefabrication degree of civil buildings. 1.0.3 This standard is applicable to the assessment on the prefabrication degree of buildings with prefabrication ratio. 1.0.4 The assessment on prefabricated buildings shall also meet the requirements of relevant current national standards in addition to this standard. 2 Terms 2.0.1 prefabricated building building made of prefabricated parts and components assembled at the construction site 2.0.2 prefabrication ratio comprehensive proportion of prefabricated parts and components adopted in main structure (above the outdoor floor of a single building), enclosure wall and inner partition wall, decoration, equipment and pipelines 2.0.3 decorated full completion of the decoration of fixed surface and installation of equipment and facilities in the building functional space meeting the basic requirements of building use function and performance 2.0.4 integrated kitchen kitchen mainly prefabricated by dry method on the construction site after design, integration and factory production of floor, ceiling, wall, cabinet, kitchen equipment and pipelines 2.0.5 integrated bathroom bathroom mainly prefabricated by dry method on the construction site after design, integration and factory production of floor, ceiling, wall, sanitary ware equipment and pipelines 3 Basic requirements 3.0.1 The calculation of prefabrication rate and the grade assessment of prefabricated buildings shall take single building as the calculation and assessment unit, and meet the following requirements: 1 Single building shall be confirmed according to the building No. of the project planning approval document; 2 When the building is composed of main building and podium, the main building and podium can be calculated and assessed according to different single buildings; 3 When the number of floors of a single building is no greater than 3 and its above-ground building area is no greater than than 500m2, a building group composed of multiple single buildings can be used as a calculation and assessment unit. 3.0.2 Assessment on prefabricated buildings shall meet the following requirements: 1 Pre-assessment should be carried out in the design stage, and the prefabrication rate shall be calculated according to the design documents; 2 The project assessment shall be carried out after the completion acceptance of the project, the prefabrication rate and assessment grade shall be calculated and determined respectively according to the completion acceptance data. 3.0.3 Prefabricated buildings shall meet the following requirements at the same time: 1 The assessment score of the main structure part is no less than 20 points; 2 The assessment score of enclosure wall and inner partition wall is no less than 10 points; 3 Full decoration is adopted; 4 The prefabrication rate is no less than 50%. 3.0.4 Prefabricated decoration should be adopted for prefabricated buildings.
Contents of GB/T 51129-2017
Foreword i 1 General provisions 2 Terms 3 Basic requirements 4 Prefabrication rate calculation 5 Assessment grading Explanation of wording in this standard
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 51129-2017, GB 51129-2017, GBT 51129-2017, GB/T51129-2017, GB/T 51129, GB/T51129, GB51129-2017, GB 51129, GB51129, GBT51129-2017, GBT 51129, GBT51129