2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 591-2008
GB/T 591-2008   Marine cast iron flanged stop check valves (English Version)
Standard No.: GB/T 591-2008 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3,000 words Translation Price(USD):60.0 remind me the price change

Email:

Implemented on:2009-2-1 Delivery: via email in 1 business day

→ → →

,,2009-2-1,1411381818607366B9EE499FDDC7E
Standard No.: GB/T 591-2008
English Name: Marine cast iron flanged stop check valves
Chinese Name: 船用法兰铸铁截止止回阀
Chinese Classification: U52    Marine valve fittings
Professional Classification: GB    National Standard
ICS Classification: 47.020.30 47.020.30    Piping systems 47.020.30
Source Content Issued by: CSSC
Issued on: 2008-8-4
Implemented on: 2009-2-1
Status: valid
Superseding:GB/T 591-1993 Marine cast iron flanged stop check valves
Target Language: English
File Format: PDF
Word Count: 3,000 words
Translation Price(USD): 60.0
Delivery: via email in 1 business day
1 Scope This standard specifies the classification and labeling, requirements, test methods, inspection rules, package and storage of marine cast iron flanged stop check valves (hereinafter referred to as stop check valves) with flange connection dimension and sealing face in accordance with those specified in GB/T 569 and GB/T 2501. This standard is applicable to the design, manufacturing and acceptance of stop check valves for pipeline system with seawater, fresh water, lubricating oil and fuel oil as medium. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments to (excluding amending errors in the text), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of the normative document is applicable. For undated references, the latest edition of the normative document applies. GB/T 569 Marine Pipe Flanges - Connection Dimensions and Mating Face GB/T 600 General Specifications for Marine Piping Valves and Fittings (GB/T 600-1991, neq ISO 5208: 1982) GB/T 1176-1987 Specification for Cast Copper Alloys (neq ISO 1338: 1977) GB/T 1184-1996 Geometrical Tolerancing - Geometrical Tolerance for Features without Individual Tolerance Indications ((eqv ISO 2768-2: 1989) GB/T 1804-2000 General Tolerances - Tolerances for Linear and Angular Dimensions without Individual Tolerance Indications (eqv ISO 2768-1: 1989) GB/T 1958 Geometrical Product Specification (GPS) - Geometrical Tolerance - Verification Prescription GB/T 2501 Marine Pipe Flanges - Connection Dimensions and Mating Face (GB/T 2501-1989, neq ISO 2084: 1974) GB/T 3032 Marks for Marine Piping Valves and Fittings GB/T 4423-1992 Copper and Copper-alloy Cold-drawn Rod and Bar GB/T 9439-1988 Grey Iron Castings GB/T 11698 Metal Valves for Use in Flanged Pipe Systems - Face-to-face and Centre-to-face Dimensions (GB/T 11698-1989, neq ISO 5752: 1982) CB/T 3927 Wall Thickness of Casting Body for Marine Valve 3 Classification and Labeling 3.1 Type The types of stop check valves are specified as follows: Type A - through-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 569; Type B - perpendicular-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 569; Type AS - through-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 2501; Type BS - perpendicular-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 2501. 3.2 Basic parameters See Table 1 for the basic parameters of stop check valve.
Foreword I 1 Scope 2 Normative References 3 Classification and Labeling 4 Requirements 5 Test Method 6 Inspection Rules 7 Package and Storage
Referred in GB/T 591-2008:
*GB/T 569-
*GB/T 600-2008 General specifications for marine piping valves and fittings
*GB/T 1176-1987 Specification for Cast Copper Alloys
*GB/T 1184-1996 Geometrical tolerancing--Geometrical tolerance for features without individual tolerance indications
*GB/T 1804-2000 General Tolerances - Tolerances for Linear and Angular Dimensions without Individual Tolerance Indications
*GB/T 1958-2004 Geometrical porduct Specifecations (GPS) - Geometrical tolerance - Verification prescription
*GB/T 2501-2010 Connection dimensions and mating face of marine flanges
*GB/T 3032-2014 Marks for Marine Piping Valves and Fittings
*GB/T 4423-1992
*GB/T 9439-1988 Grey iron castings
*GB/T 11698-2008 Metal valves for use in marine flanged pipe systems - Face-to-face and center-to-face dimensions
*CB/T 3927-1999 Wall thickness of casting body for marine valve
Code of China
Standard
GB/T 591-2008  Marine cast iron flanged stop check valves (English Version)
Standard No.GB/T 591-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count3,000 words
Price(USD)60.0
Implemented on2009-2-1
Deliveryvia email in 1 business day
Detail of GB/T 591-2008
Standard No.
GB/T 591-2008
English Name
Marine cast iron flanged stop check valves
Chinese Name
船用法兰铸铁截止止回阀
Chinese Classification
U52
Professional Classification
GB
ICS Classification
Issued by
CSSC
Issued on
2008-8-4
Implemented on
2009-2-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 591-1993 Marine cast iron flanged stop check valves
Language
English
File Format
PDF
Word Count
3,000 words
Price(USD)
60.0
Keywords
GB/T 591-2008, GB 591-2008, GBT 591-2008, GB/T591-2008, GB/T 591, GB/T591, GB591-2008, GB 591, GB591, GBT591-2008, GBT 591, GBT591
Introduction of GB/T 591-2008
1 Scope This standard specifies the classification and labeling, requirements, test methods, inspection rules, package and storage of marine cast iron flanged stop check valves (hereinafter referred to as stop check valves) with flange connection dimension and sealing face in accordance with those specified in GB/T 569 and GB/T 2501. This standard is applicable to the design, manufacturing and acceptance of stop check valves for pipeline system with seawater, fresh water, lubricating oil and fuel oil as medium. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments to (excluding amending errors in the text), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of the normative document is applicable. For undated references, the latest edition of the normative document applies. GB/T 569 Marine Pipe Flanges - Connection Dimensions and Mating Face GB/T 600 General Specifications for Marine Piping Valves and Fittings (GB/T 600-1991, neq ISO 5208: 1982) GB/T 1176-1987 Specification for Cast Copper Alloys (neq ISO 1338: 1977) GB/T 1184-1996 Geometrical Tolerancing - Geometrical Tolerance for Features without Individual Tolerance Indications ((eqv ISO 2768-2: 1989) GB/T 1804-2000 General Tolerances - Tolerances for Linear and Angular Dimensions without Individual Tolerance Indications (eqv ISO 2768-1: 1989) GB/T 1958 Geometrical Product Specification (GPS) - Geometrical Tolerance - Verification Prescription GB/T 2501 Marine Pipe Flanges - Connection Dimensions and Mating Face (GB/T 2501-1989, neq ISO 2084: 1974) GB/T 3032 Marks for Marine Piping Valves and Fittings GB/T 4423-1992 Copper and Copper-alloy Cold-drawn Rod and Bar GB/T 9439-1988 Grey Iron Castings GB/T 11698 Metal Valves for Use in Flanged Pipe Systems - Face-to-face and Centre-to-face Dimensions (GB/T 11698-1989, neq ISO 5752: 1982) CB/T 3927 Wall Thickness of Casting Body for Marine Valve 3 Classification and Labeling 3.1 Type The types of stop check valves are specified as follows: Type A - through-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 569; Type B - perpendicular-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 569; Type AS - through-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 2501; Type BS - perpendicular-type stop check valve with flange connection dimension and sealing face in accordance with GB/T 2501. 3.2 Basic parameters See Table 1 for the basic parameters of stop check valve.
Contents of GB/T 591-2008
Foreword I 1 Scope 2 Normative References 3 Classification and Labeling 4 Requirements 5 Test Method 6 Inspection Rules 7 Package and Storage
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 591-2008, GB 591-2008, GBT 591-2008, GB/T591-2008, GB/T 591, GB/T591, GB591-2008, GB 591, GB591, GBT591-2008, GBT 591, GBT591