GB/Z 19964-2005   Technical rule for connecting PV power station to electric power systems (English Version)
Standard No.: GB/Z 19964-2005 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):304.0 remind me the price change

Email:

Implemented on:2006-2-1 Delivery: via email in 1 business day

→ → →

,2013-6-1,2006-2-1,1411381818070515DF5C4F5E80442
Standard No.: GB/Z 19964-2005
English Name: Technical rule for connecting PV power station to electric power systems
Chinese Name: 光伏发电站接入电力系统技术规定
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ; SAC
Issued on: 2005-12-12
Implemented on: 2006-2-1
Status: superseded
Superseded by:GB/T 19964-2012 Technical requirements for connecting photovoltaic power station to power system
Superseded on:2013-6-1
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 304.0
Delivery: via email in 1 business day
1 Scope This technical guide specifies the technical requirements for connecting large-scale PV power station (100KW or above) to electric power systems. This technical guide is applicable to PV power stations connected to the grid by electric transmission line (voltage class of 10 KV or above). 2 Normative References The following documents contain provisions which, through reference in this text, constitute provisions of this technical guide. For dated reference, subsequent amendments to (excluding the correction contents), or revisions of, any of these publications do not apply. However, parties to agreements based on this technical guide are encouraged to investigate the possibility of applying the most recent editions of the documents indicated below. For undated references, the latest editions of the normative documents are applicable to this technical guide. GB/T 2297-1989 “Terminology for Solar Photovoltaic Energy System” GB/T 12325-2003 “Power Quality-Admissible Deviation of Supply Voltage” GB 12326-2000 “Power Quality-Voltage Fluctuation and Flicker” GB/T 14549-1993 “Quality of Electric Energy Supply-Harmonics in Public Supply Network” GB/T 15543-1995 “Quality of Electric Energy Supply-Admissible Three-Phase Voltage Unbalance Factor” GB/T 15945-1995 “Quality of Electric Energy Supply-Permissible Deviation of Frequency for Power System” GB/T 18479-2001 “Terrestrial Photovoltaic (PV) Power Generating Systems--General and Guide” GB 16179-1996 “Guidelines for the Use of Safety Signs” 3 Terms and Definitions The following terms and definitions are applicable to this technical guide. 3.1 PV power station A large-scale PV power generation system consisted of one or more photovoltaic power subsystems, converting sunlight energy directly to electric energy. 3.2 Photovoltaic power subsystem A system including (one or more) grid connection inverters and relevant BOS (components of balance system), as well as a solar-cell-array with one point of common coupling. 3.3 Active power of PV power station Total active power output from PV power station. 3.4 Reactive power of PV power station Total reactive power output from PV power station. 3.5 Power factor of PV power station Power factor calculated by the total active power and total reactive power output from PV power station. The power factor (PF) shall be calculated by the following formula:
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Power Quality of PV Power Station 5 Active Power of PV Power Station 6 Reactive Power of PV Power Station 7 Operating Voltage of PV Power Station 8 Voltage Regulation of PV Power Station 9 Operation Test of PV Power Station 10 Communication and Signal
Referred in GB/Z 19964-2005:
*GB/T 2297-1989 Terminology for solar photovoltaic energy system
*GB/T 12325-2003 Power quality--Admissible deviation of supply voltage
*GB 12326-2000 Power quality--Voltage fluctuation and flicker
*GB/T 14549-1993 Quality of Electric Energy Supply - Harmonics in Public Supply Network
*GB/T 15543-1995 Quality of electric energy supply-Admissible three-phase voltage unbalance factor
*GB/T 15945-1995 Quality of electric energy supply Permissible deviation of frequency for power system
*GB/T 18479-2001 Terrestrial photovoltaic (PV) power generating systems--General and guide
*GB 16179-1996 Guidelines for the use of safety signs
Code of China
Standard
GB/Z 19964-2005  Technical rule for connecting PV power station to electric power systems (English Version)
Standard No.GB/Z 19964-2005
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)304.0
Implemented on2006-2-1
Deliveryvia email in 1 business day
Detail of GB/Z 19964-2005
Standard No.
GB/Z 19964-2005
English Name
Technical rule for connecting PV power station to electric power systems
Chinese Name
光伏发电站接入电力系统技术规定
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2005-12-12
Implemented on
2006-2-1
Status
superseded
Superseded by
GB/T 19964-2012 Technical requirements for connecting photovoltaic power station to power system
Superseded on
2013-6-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
304.0
Keywords
GB/Z 19964-2005, GB/ZT 19964-2005, GBZT 19964-2005, GB/Z19964-2005, GB/Z 19964, GB/Z19964, GB/ZT19964-2005, GB/ZT 19964, GB/ZT19964, GBZT19964-2005, GBZT 19964, GBZT19964
Introduction of GB/Z 19964-2005
1 Scope This technical guide specifies the technical requirements for connecting large-scale PV power station (100KW or above) to electric power systems. This technical guide is applicable to PV power stations connected to the grid by electric transmission line (voltage class of 10 KV or above). 2 Normative References The following documents contain provisions which, through reference in this text, constitute provisions of this technical guide. For dated reference, subsequent amendments to (excluding the correction contents), or revisions of, any of these publications do not apply. However, parties to agreements based on this technical guide are encouraged to investigate the possibility of applying the most recent editions of the documents indicated below. For undated references, the latest editions of the normative documents are applicable to this technical guide. GB/T 2297-1989 “Terminology for Solar Photovoltaic Energy System” GB/T 12325-2003 “Power Quality-Admissible Deviation of Supply Voltage” GB 12326-2000 “Power Quality-Voltage Fluctuation and Flicker” GB/T 14549-1993 “Quality of Electric Energy Supply-Harmonics in Public Supply Network” GB/T 15543-1995 “Quality of Electric Energy Supply-Admissible Three-Phase Voltage Unbalance Factor” GB/T 15945-1995 “Quality of Electric Energy Supply-Permissible Deviation of Frequency for Power System” GB/T 18479-2001 “Terrestrial Photovoltaic (PV) Power Generating Systems--General and Guide” GB 16179-1996 “Guidelines for the Use of Safety Signs” 3 Terms and Definitions The following terms and definitions are applicable to this technical guide. 3.1 PV power station A large-scale PV power generation system consisted of one or more photovoltaic power subsystems, converting sunlight energy directly to electric energy. 3.2 Photovoltaic power subsystem A system including (one or more) grid connection inverters and relevant BOS (components of balance system), as well as a solar-cell-array with one point of common coupling. 3.3 Active power of PV power station Total active power output from PV power station. 3.4 Reactive power of PV power station Total reactive power output from PV power station. 3.5 Power factor of PV power station Power factor calculated by the total active power and total reactive power output from PV power station. The power factor (PF) shall be calculated by the following formula:
Contents of GB/Z 19964-2005
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Power Quality of PV Power Station 5 Active Power of PV Power Station 6 Reactive Power of PV Power Station 7 Operating Voltage of PV Power Station 8 Voltage Regulation of PV Power Station 9 Operation Test of PV Power Station 10 Communication and Signal