2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 1012-2007
JB/T 1012-2007   Specification for YY series permanent-split capacitor asynchronous motors (English Version)
Standard No.: JB/T 1012-2007 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3500 words Translation Price(USD):150.0 remind me the price change

Email:

Implemented on:2007-7-1 Delivery: via email in 1 business day

→ → →

,2018-4-1,2007-7-1,141137539637642DCA36D36E6D7A2
Standard No.: JB/T 1012-2007
English Name: Specification for YY series permanent-split capacitor asynchronous motors
Chinese Name: YY系列电容运转异步电动机技术条件
Chinese Classification: K22    Asynchronous machine
Professional Classification: JB    Professional Standard - Machinery
ICS Classification: 29.160.30 29.160.30    Motors 29.160.30
Source Content Issued by: NDRC
Issued on: 2007-01-25
Implemented on: 2007-7-1
Status: superseded
Superseded by:JB/T 1012-2017 Technical specification for YY series permanent-split capacitor asynchronous motors
Superseded on:2018-4-1
Superseding:JB/T 1012-1991
Target Language: English
File Format: PDF
Word Count: 3500 words
Translation Price(USD): 150.0
Delivery: via email in 1 business day
1 Scope This standard specifies the YY series permanent-split capacitor asynchronous motors in terms of type, basic parameters and dimension, technical requirements, test methods, inspection rules, marking, packaging, storage and transportation and warranty period. This standard is applicable to YY series permanent-split capacitor asynchronous motors (frame size 45~90) (hereinafter referred to as "motors"), and all other series motors derived from YY series permanent-split capacitor asynchronous motors may also refer. 2 Normative References The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780:1997) GB 755-2000 Rotating Electrical Machines - Rating and Performance (idt IEC60034-1:1996) GB/T 2828.1-2003 Sampling Procedures for Inspection by Attributea - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit(AQL) for Lot-by-Lot Inspection (ISO 2859-1:1999, IDT) GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame numbers 56 to 400 and Flange Numbers 55 to 1080 (idt IEC 60072-1:1991) GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification (IEC 60034-5:2000, IDT) GB 10069.1-2006 Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines (ISO 1680:1999, MOD) GB 12350-2000 Safety Requirements of Small-power Motors GB/T 12665-1990 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environmental Condition JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 10490-2004 Mechanical Vibration of Small Power Motors - Measurement, Evaluation and Limits of Vibration 3 Types, Basic Parameters and Dimensions 3.1 The protection level of motor enclosure adopts IP44, IP54 or IP55. 3.2 Method of cooling motor: IC 0141 for frame size ≥63; IC 0041 for frame size ≤56. 3.3 The construction and mounting type of motors shall meet the requirements of Table 1. Table 1 Frame size Construction and mounting code (IM) 45~56 B3, B14, B34, V5, V6, V18, V19 63~80 B3, B5, B14, B34, VI, V3, V5, V6, V18, V19 90 B3, B5, B14, B34, B35, VI, V3, V5, V6, V18, V19, V36 3.4 Rating of the motor is continuous based on continuous duty (S1). 3.5 The rated frequency of the motor is 50Hz; the rated voltage is 220V. 3.6 Motors shall be manufactured according to the following rated powers (in W): 10, 16, 25, 40, 60, 90, 120, 180, 250, 370, 550, 750, 1100, 1500, 2200. 3.7 The corresponding relation of frame size, rotating speed and power of motors shall be in accordance with those specified in Table 2.
Contents Foreword I 1 Scope 2 Normative References 3 Types, Basic Parameters and Dimensions 4 Technical Requirements 5 Test Method 6 Inspection Rules 7 Marking, Packaging, Storing and Transportation 8 Quality Warranty Period
Referred in JB/T 1012-2007:
*GB/T 191-2000 Packaging - Pictorial marking for handling of goods
*GB 755-2000 Rotating electrical machines--Rating and performance
*GB/T 2828.1-2003 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines -Part 1:Frame numbers 56 to 400 and flange numbers 55 to 1 080
*GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machined (IP Code)-Classification
*GB10069.1-2006
*GB 12350-2000 Safety requirments of small power motors
*GB/T 12665-1990 Requirements of damp-heat testing of electrical machine for service in general environmental condition
*JB/T 9615.1-2000 test methods of the interturn insulation on random wound winding for ac low-voltage machines
*JB/T 9615.2-2000 test limits of the interturn insulation on random wound winding for ac low-voltage machines
*JB/T 10490-2004 Mechanical vibration of small power motors—measurement,evaluation and limits of vibration
Code of China
Standard
JB/T 1012-2007  Specification for YY series permanent-split capacitor asynchronous motors (English Version)
Standard No.JB/T 1012-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count3500 words
Price(USD)150.0
Implemented on2007-7-1
Deliveryvia email in 1 business day
Detail of JB/T 1012-2007
Standard No.
JB/T 1012-2007
English Name
Specification for YY series permanent-split capacitor asynchronous motors
Chinese Name
YY系列电容运转异步电动机技术条件
Chinese Classification
K22
Professional Classification
JB
ICS Classification
Issued by
NDRC
Issued on
2007-01-25
Implemented on
2007-7-1
Status
superseded
Superseded by
JB/T 1012-2017 Technical specification for YY series permanent-split capacitor asynchronous motors
Superseded on
2018-4-1
Abolished on
Superseding
JB/T 1012-1991
Language
English
File Format
PDF
Word Count
3500 words
Price(USD)
150.0
Keywords
JB/T 1012-2007, JB 1012-2007, JBT 1012-2007, JB/T1012-2007, JB/T 1012, JB/T1012, JB1012-2007, JB 1012, JB1012, JBT1012-2007, JBT 1012, JBT1012
Introduction of JB/T 1012-2007
1 Scope This standard specifies the YY series permanent-split capacitor asynchronous motors in terms of type, basic parameters and dimension, technical requirements, test methods, inspection rules, marking, packaging, storage and transportation and warranty period. This standard is applicable to YY series permanent-split capacitor asynchronous motors (frame size 45~90) (hereinafter referred to as "motors"), and all other series motors derived from YY series permanent-split capacitor asynchronous motors may also refer. 2 Normative References The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780:1997) GB 755-2000 Rotating Electrical Machines - Rating and Performance (idt IEC60034-1:1996) GB/T 2828.1-2003 Sampling Procedures for Inspection by Attributea - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit(AQL) for Lot-by-Lot Inspection (ISO 2859-1:1999, IDT) GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame numbers 56 to 400 and Flange Numbers 55 to 1080 (idt IEC 60072-1:1991) GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification (IEC 60034-5:2000, IDT) GB 10069.1-2006 Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines (ISO 1680:1999, MOD) GB 12350-2000 Safety Requirements of Small-power Motors GB/T 12665-1990 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environmental Condition JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines JB/T 10490-2004 Mechanical Vibration of Small Power Motors - Measurement, Evaluation and Limits of Vibration 3 Types, Basic Parameters and Dimensions 3.1 The protection level of motor enclosure adopts IP44, IP54 or IP55. 3.2 Method of cooling motor: IC 0141 for frame size ≥63; IC 0041 for frame size ≤56. 3.3 The construction and mounting type of motors shall meet the requirements of Table 1. Table 1 Frame size Construction and mounting code (IM) 45~56 B3, B14, B34, V5, V6, V18, V19 63~80 B3, B5, B14, B34, VI, V3, V5, V6, V18, V19 90 B3, B5, B14, B34, B35, VI, V3, V5, V6, V18, V19, V36 3.4 Rating of the motor is continuous based on continuous duty (S1). 3.5 The rated frequency of the motor is 50Hz; the rated voltage is 220V. 3.6 Motors shall be manufactured according to the following rated powers (in W): 10, 16, 25, 40, 60, 90, 120, 180, 250, 370, 550, 750, 1100, 1500, 2200. 3.7 The corresponding relation of frame size, rotating speed and power of motors shall be in accordance with those specified in Table 2.
Contents of JB/T 1012-2007
Contents Foreword I 1 Scope 2 Normative References 3 Types, Basic Parameters and Dimensions 4 Technical Requirements 5 Test Method 6 Inspection Rules 7 Marking, Packaging, Storing and Transportation 8 Quality Warranty Period
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 1012-2007, JB 1012-2007, JBT 1012-2007, JB/T1012-2007, JB/T 1012, JB/T1012, JB1012-2007, JB 1012, JB1012, JBT1012-2007, JBT 1012, JBT1012