2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 7565.4-2004
JB/T 7565.4-2004   Specification of flameproof three phases asynchronous motor Part 4:Series YB2 flameproof (Exd Ⅱ CT1~T4) three phases asynchronous motor (Frame size 63 to 355) (English Version)
Standard No.: JB/T 7565.4-2004 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):100.0 remind me the price change

Email:

Implemented on:2005-4-1 Delivery: via email in 1 business day

→ → →

,2016-3-1,2005-4-1,14113742844204EDC0C311ACCD0CC
Standard No.: JB/T 7565.4-2004
English Name: Specification of flameproof three phases asynchronous motor Part 4:Series YB2 flameproof (Exd Ⅱ CT1~T4) three phases asynchronous motor (Frame size 63 to 355)
Chinese Name: 隔爆型三相异步电动机技术条件 第4部分:YB2系列隔爆型(ExdⅡCT1~T4)三相异步电动机 (机座号63~355)
Chinese Classification: K25    Explosion-proof electric machine
Professional Classification: JB    Professional Standard - Machinery
ICS Classification: 29.260.20 29.260.20    Electrical apparatus for explosive atmospheres 29.260.20
Source Content Issued by: National Subcommittee on Explosion-proof Electric Motors
Issued on: 2004-10-20
Implemented on: 2005-4-1
Status: superseded
Superseded by:JB/T 7565.4-2015 Specification of flameproof three-phase asynchronous motor. Part 4-YB3 series flameproof(Ex d II CT1~T4)three-phase asynchronous motor(frame size 63 to 355)
Superseded on:2016-3-1
Superseding:JB/T 5338-1991
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 100.0
Delivery: via email in 1 business day
1 Scope This standard specifies the YB 2 flame-proof (Exd II CTl-T4) three-phase asynchronous motor in terms of type, basic parameters and dimension, technical requirements, test methods, inspection rules and requirements for marking and packaging. This standard is applicable to flame-proof (ExdⅡCTl-T4) three-phase asynchronous motor (frame size 63-355) (hereinafter referred to as motor) and used by motors derived from this series for reference. 2 Normative References The following standards contain provisions which, through reference in this part of JB/T 7565, constitute provisions of this part. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards indicated below apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191 Packaging - Pictorial Marking for Handling of Goods (GB/T 191-2000, eqv IS0 780:1997) GB 755 Rotating Electrical Machines - Rating and Performance (GB 755-2000, idt IEC 60034-1:1996) GB/T 1032 Test Procedure for Three-phase Induction Motors GB 3836.1 Electrical Apparatus for Explosive Gas Atmospheres - Part 1: General Requirements (GB 3836.1-2000, eqv IEC 60079-0:1998) GB 3836.2 Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Flameproof Enclosure “d” (GB 3836.2-2000, eqv IEC 60079-1: 1990) GB/T 4772.1 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame Numbers 56 to 400 and Flange Numbers 55 to 1080 ( GB/T 4772.1-1999, idt IEC 60072-1:1991) GB/T 4942.1 Classification of Degrees of Protection Provided by Enclosures of Rotating Electrical Machines (IP Code) (GB/T 4942.1-2001, idt IEC 60034-5:1991) GB 10068 Mechanical Vibration of Certain Machines with Shaft Heights 56mm and Higher - Measurement, Evaluation and Limits of Vibration Severity (GB 10068-2000, idt IEC 60034-14: 1996) GB/T 10069.1 Measurement of Airborne Noise Emitted by Rotating Electrical Machinery and the Noise Limits - Engineering Method for the Measurement of Airborne Noise (GB/T 10069.1-1988, neq ISO1680-1:1986) GB/T l2665 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environmental Condition JB/T 9615.1 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines 3 Type, Basic Parameters and Dimensions 3.1 The motors shall be made into flameproof type according to the requirements of GB 3836.2, and the explosion-proof marks are ExdⅡCT1, ExdⅡCT2, ExdⅡCT3, ExdⅡCT4. 3.2 Motor enclosure protection level is IP 55. 3.3 The cooling method of motors is IC4II. 3.4 Construction and mounting type of motor are IMB3, IMB5, IMB6, IMB7, IMB8, IMB14, IMB34, IMB35, IMV1, IMV3, IMV5, IMV6, IMV15, IMV18 and IMV36 and the motor shall be manufactured according to those specified in Table 1. Table 1 Frame size Construction and mounting type (IM) 63~71 B3, B5, B6, B7, B8, B14, B34, V1, V3, V5, V6, V18 80~112 B3, B5, B6, B7, B8, B14, B34, B35, V1, V3, V5, V6, V15, V18, V36 132~160 B3, B5, B6, B7, B8, B35, V1, V3, V5, V6, V15, V36 180~280 B3, B5, B35, V1 315~355 B3, B35, V1 3.5 Rating of the motor is continuous based on continuous duty (S1). 3.6 The rated frequency of motors is 50Hz , and the rated voltages are 380V, 660V and 380V/660V. The motors with power of 3kW or below shall be of Y-connection, and the rated voltage is 380V. 3.7 Motors shall be manufactured according to the following rated powers: 0.12kW, 0.18kW, 0.25kW, 0.37kW, 0.55kW, 0.75kW,1.1kW,1.5kW, 2.2kW, 3kW, 4kW, 5.5kW,7.5kW, 11kW, 15kW, 18.5kW, 22kW, 30kW, 37kW, 45kW, 55kW, 75kW, 90kW, 110kW, 132kW, 160kW, (185kW), 200kW, (220kW),250kW, (280kW), 315kW. Note: The above specifications in brackets are not recommended. 3.8 The corresponding relation between the frame size and rotating speed/power of motors shall be in accordance with those specified in Table 2. Table 2
Contents Foreword I 1 Scope 2 Normative References 3 Type, Basic Parameters and Dimensions 4 Technical Requirements 5 Test Methods and Inspection Rules 6 Marking and Packaging
Referred in JB/T 7565.4-2004:
*GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
*GB 755-2008 Rotating Electrical Machines - Rating and Performance
*GB/T 1032-2023 Iron ores—Determination of specific surface area—Test method using air-permeability apparatus (Blaine)
*GB 3836.1-2010 Explosive atmospheres—Part 1:Equipment—General requirements
*GB 3836.2-2010 Explosive atmospheres—Part 2:Equipment protection by flameproof enclosures“d”
*GB/T 4772.1-1999 Dimensions and output series for rotating electrical machines -Part 1:Frame numbers 56 to 400 and flange numbers 55 to 1 080
*GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machined (IP Code)-Classification
*GB 10068-2008 Mechanical vibration of certain machines with shaft heights 56 mm and higher-measurement evaluation and limits of vibration severity
*GB/T 10069.1-2006 Measurement of airborne noise emitted by rotating electrical machines and the noise limits Part 1: Method for the measurement of airborne noise emitted by rotating electrical machines
*GBTl2665-
*JB/T 9615.1-2000 test methods of the interturn insulation on random wound winding for ac low-voltage machines
Code of China
Standard
JB/T 7565.4-2004  Specification of flameproof three phases asynchronous motor Part 4:Series YB2 flameproof (Exd Ⅱ CT1~T4) three phases asynchronous motor (Frame size 63 to 355) (English Version)
Standard No.JB/T 7565.4-2004
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)100.0
Implemented on2005-4-1
Deliveryvia email in 1 business day
Detail of JB/T 7565.4-2004
Standard No.
JB/T 7565.4-2004
English Name
Specification of flameproof three phases asynchronous motor Part 4:Series YB2 flameproof (Exd Ⅱ CT1~T4) three phases asynchronous motor (Frame size 63 to 355)
Chinese Name
隔爆型三相异步电动机技术条件 第4部分:YB2系列隔爆型(ExdⅡCT1~T4)三相异步电动机 (机座号63~355)
Chinese Classification
K25
Professional Classification
JB
ICS Classification
Issued by
National Subcommittee on Explosion-proof Electric Motors
Issued on
2004-10-20
Implemented on
2005-4-1
Status
superseded
Superseded by
JB/T 7565.4-2015 Specification of flameproof three-phase asynchronous motor. Part 4-YB3 series flameproof(Ex d II CT1~T4)three-phase asynchronous motor(frame size 63 to 355)
Superseded on
2016-3-1
Abolished on
Superseding
JB/T 5338-1991
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
100.0
Keywords
JB/T 7565.4-2004, JB 7565.4-2004, JBT 7565.4-2004, JB/T7565.4-2004, JB/T 7565.4, JB/T7565.4, JB7565.4-2004, JB 7565.4, JB7565.4, JBT7565.4-2004, JBT 7565.4, JBT7565.4
Introduction of JB/T 7565.4-2004
1 Scope This standard specifies the YB 2 flame-proof (Exd II CTl-T4) three-phase asynchronous motor in terms of type, basic parameters and dimension, technical requirements, test methods, inspection rules and requirements for marking and packaging. This standard is applicable to flame-proof (ExdⅡCTl-T4) three-phase asynchronous motor (frame size 63-355) (hereinafter referred to as motor) and used by motors derived from this series for reference. 2 Normative References The following standards contain provisions which, through reference in this part of JB/T 7565, constitute provisions of this part. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards indicated below apply. For undated references, the latest editions of the normative documents referred to apply. GB/T 191 Packaging - Pictorial Marking for Handling of Goods (GB/T 191-2000, eqv IS0 780:1997) GB 755 Rotating Electrical Machines - Rating and Performance (GB 755-2000, idt IEC 60034-1:1996) GB/T 1032 Test Procedure for Three-phase Induction Motors GB 3836.1 Electrical Apparatus for Explosive Gas Atmospheres - Part 1: General Requirements (GB 3836.1-2000, eqv IEC 60079-0:1998) GB 3836.2 Electrical Apparatus for Explosive Gas Atmospheres - Part 2: Flameproof Enclosure “d” (GB 3836.2-2000, eqv IEC 60079-1: 1990) GB/T 4772.1 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame Numbers 56 to 400 and Flange Numbers 55 to 1080 ( GB/T 4772.1-1999, idt IEC 60072-1:1991) GB/T 4942.1 Classification of Degrees of Protection Provided by Enclosures of Rotating Electrical Machines (IP Code) (GB/T 4942.1-2001, idt IEC 60034-5:1991) GB 10068 Mechanical Vibration of Certain Machines with Shaft Heights 56mm and Higher - Measurement, Evaluation and Limits of Vibration Severity (GB 10068-2000, idt IEC 60034-14: 1996) GB/T 10069.1 Measurement of Airborne Noise Emitted by Rotating Electrical Machinery and the Noise Limits - Engineering Method for the Measurement of Airborne Noise (GB/T 10069.1-1988, neq ISO1680-1:1986) GB/T l2665 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environmental Condition JB/T 9615.1 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines 3 Type, Basic Parameters and Dimensions 3.1 The motors shall be made into flameproof type according to the requirements of GB 3836.2, and the explosion-proof marks are ExdⅡCT1, ExdⅡCT2, ExdⅡCT3, ExdⅡCT4. 3.2 Motor enclosure protection level is IP 55. 3.3 The cooling method of motors is IC4II. 3.4 Construction and mounting type of motor are IMB3, IMB5, IMB6, IMB7, IMB8, IMB14, IMB34, IMB35, IMV1, IMV3, IMV5, IMV6, IMV15, IMV18 and IMV36 and the motor shall be manufactured according to those specified in Table 1. Table 1 Frame size Construction and mounting type (IM) 63~71 B3, B5, B6, B7, B8, B14, B34, V1, V3, V5, V6, V18 80~112 B3, B5, B6, B7, B8, B14, B34, B35, V1, V3, V5, V6, V15, V18, V36 132~160 B3, B5, B6, B7, B8, B35, V1, V3, V5, V6, V15, V36 180~280 B3, B5, B35, V1 315~355 B3, B35, V1 3.5 Rating of the motor is continuous based on continuous duty (S1). 3.6 The rated frequency of motors is 50Hz , and the rated voltages are 380V, 660V and 380V/660V. The motors with power of 3kW or below shall be of Y-connection, and the rated voltage is 380V. 3.7 Motors shall be manufactured according to the following rated powers: 0.12kW, 0.18kW, 0.25kW, 0.37kW, 0.55kW, 0.75kW,1.1kW,1.5kW, 2.2kW, 3kW, 4kW, 5.5kW,7.5kW, 11kW, 15kW, 18.5kW, 22kW, 30kW, 37kW, 45kW, 55kW, 75kW, 90kW, 110kW, 132kW, 160kW, (185kW), 200kW, (220kW),250kW, (280kW), 315kW. Note: The above specifications in brackets are not recommended. 3.8 The corresponding relation between the frame size and rotating speed/power of motors shall be in accordance with those specified in Table 2. Table 2
Contents of JB/T 7565.4-2004
Contents Foreword I 1 Scope 2 Normative References 3 Type, Basic Parameters and Dimensions 4 Technical Requirements 5 Test Methods and Inspection Rules 6 Marking and Packaging
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 7565.4-2004, JB 7565.4-2004, JBT 7565.4-2004, JB/T7565.4-2004, JB/T 7565.4, JB/T7565.4, JB7565.4-2004, JB 7565.4, JB7565.4, JBT7565.4-2004, JBT 7565.4, JBT7565.4