2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JGJ 107-2003
JGJ 107-2003   General technical specification for mechanical splicing of bars (English Version)
Standard No.: JGJ 107-2003 Status:abolished remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):150.0 remind me the price change

Email:

Implemented on:2003-7-1 Delivery: via email in 1 business day

→ → →

2010-10-01 ,2010-10-1,2003-7-1,141137407264239305C2780D2B626
Standard No.: JGJ 107-2003
English Name: General technical specification for mechanical splicing of bars
Chinese Name: 钢筋机械连接通用技术规程
Chinese Classification: P25    Concrete structure engineering
Professional Classification: JG    Professional Standard - Building
ICS Classification: 91.080.40 91.080.40    Concrete structures 91.080.40
Source Content Issued by: MOC
Issued on: 2003-3-21
Implemented on: 2003-7-1
Status: abolished
Superseded by:JGJ 107-2010 Technical specification for mechanical splicing of steel reinforcing bars
Superseded on:2010-10-1
Abolished on:2010-10-01
Superseding:JGJ 107-1996 General Technical Specification for Mechanical Splicing of Bars
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 150.0
Delivery: via email in 1 business day
1.0.1 In order to use rebar mechanical joint with state-of-art technology, security and adaptability, economic feasibility and quality guaranteed, the regulation is constituted. 1.0.2 The regulation is applied to the design, application and acceptance of mechanical splicing component(hereinafter referred to as splicing component or joint)used in house and normal construction. The application of various mechanical splicing components should comply with specifications in the regulation. 1.0.3 The rebar used in mechanical splicing should correspond with the specifications of national standard "Hot Rolled Ribbed Bars for the Reinforcement of Concrete" 1499 and "Remained Heat Treatment Ribbed Steel Bars for the Reinforcement of Concrete" GB 13014. The regulation should be executed according to the active resolved compelling specifications.
Foreword 1. General Provision 2. Terms and Signs 3 Design Principles and Performance Rate of Splicing 4 the Application of Splicing Component 6 The Test and Acceptance of Splicing Component in Construction Site Appendix A the Loading System of Splicing Component Type Examination Annex B Type Examination Report of Test Splicing Component Wording Explanation
Code of China
Standard
JGJ 107-2003  General technical specification for mechanical splicing of bars (English Version)
Standard No.JGJ 107-2003
Statusabolished
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)150.0
Implemented on2003-7-1
Deliveryvia email in 1 business day
Detail of JGJ 107-2003
Standard No.
JGJ 107-2003
English Name
General technical specification for mechanical splicing of bars
Chinese Name
钢筋机械连接通用技术规程
Chinese Classification
P25
Professional Classification
JG
ICS Classification
Issued by
MOC
Issued on
2003-3-21
Implemented on
2003-7-1
Status
abolished
Superseded by
JGJ 107-2010 Technical specification for mechanical splicing of steel reinforcing bars
Superseded on
2010-10-1
Abolished on
2010-10-01
Superseding
JGJ 107-1996 General Technical Specification for Mechanical Splicing of Bars
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
150.0
Keywords
JGJ 107-2003, JGJ/T 107-2003, JGJT 107-2003, JGJ107-2003, JGJ 107, JGJ107, JGJ/T107-2003, JGJ/T 107, JGJ/T107, JGJT107-2003, JGJT 107, JGJT107
Introduction of JGJ 107-2003
1.0.1 In order to use rebar mechanical joint with state-of-art technology, security and adaptability, economic feasibility and quality guaranteed, the regulation is constituted. 1.0.2 The regulation is applied to the design, application and acceptance of mechanical splicing component(hereinafter referred to as splicing component or joint)used in house and normal construction. The application of various mechanical splicing components should comply with specifications in the regulation. 1.0.3 The rebar used in mechanical splicing should correspond with the specifications of national standard "Hot Rolled Ribbed Bars for the Reinforcement of Concrete" 1499 and "Remained Heat Treatment Ribbed Steel Bars for the Reinforcement of Concrete" GB 13014. The regulation should be executed according to the active resolved compelling specifications.
Contents of JGJ 107-2003
Foreword 1. General Provision 2. Terms and Signs 3 Design Principles and Performance Rate of Splicing 4 the Application of Splicing Component 6 The Test and Acceptance of Splicing Component in Construction Site Appendix A the Loading System of Splicing Component Type Examination Annex B Type Examination Report of Test Splicing Component Wording Explanation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JGJ 107-2003, JGJ/T 107-2003, JGJT 107-2003, JGJ107-2003, JGJ 107, JGJ107, JGJ/T107-2003, JGJ/T 107, JGJ/T107, JGJT107-2003, JGJT 107, JGJT107