2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JGJ 140-2004
JGJ 140-2004   Specification for Seismic Design of Prestressed Concrete Structures (English Version)
Standard No.: JGJ 140-2004 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:2004-5-1 Delivery: via email in 1 business day

→ → →

,2020-2-1,2004-5-1,14113743125356D54BC2CF3525DF8
Standard No.: JGJ 140-2004
English Name: Specification for Seismic Design of Prestressed Concrete Structures
Chinese Name: 预应力混凝土结构抗震设计规程
Chinese Classification: 301    
Professional Classification: JG    Professional Standard - Building
ICS Classification: 91.120.25 91.120.25    Seismic and vibration protection 91.120.25
Source Content Issued by: MOC
Issued on: 2004-01-29
Implemented on: 2004-5-1
Status: superseded
Superseded by:JGJ/T 140-2019 Standard for seismic design of prestressed concrete structures
Superseded on:2020-2-1
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This standard was formulated to implement the guideline on prevention first in seismic operation, lighten the seismic destructiveness of the prestressed concrete building structures after the seismic protection, avoid the casualties and reduce the economic loss. 1.0.2 This standard is applicable to the seismic design of such building structures as the cast-in-situ post-tensioned prestressed concrete frame and slab-column in the areas with seismic protection intensity of 6~8 magnitude; however, the seismic design of the prestressed concrete structures in the areas with seismic protection intensity of 9 magnitude shall be with full references and adopted with reliable measures. 1.0.3 The seismic design of the prestressed concrete building structure shall not only comply with this standard, but also shall comply with those specified in the current relevant national compulsory standards. 2 Terms and Symbols 2.1 Terms 2.1.1 Damping ratio It is the ratio of the actual resistance of damped vibration and the resistance required for generating the critical damping. 2.1.2 It is the ratio of axial compressive force to axial compressive ultimate capacity of section under combination of earthquake action It is the ratio between the design value of the axial pressure of concrete column under the combination of the earthquake action and the arithmetic product of the bulk cross-section area of column with the design value of concrete compressive strength; as for the prestressed concrete column, it shall be taken as the design axial force value of the combination in which the prestress action participates. 2.1.3 Post-tensioned bonded prestressed concrete structure It is the bonded concrete structure by stretching and anchoring the prestressed reinforcements to establish prestress after the concrete has been hardened, and then grouting in the pipe, for instance, prestressed concrete frame and portal. 2.1.4 Unbonded prestressed concrete structure It is the post-stressed concrete structure that is allocated with such prestressed reinforcements with paint coat and cladding but does not bond with concrete. 2.2 Symbols 2.2.1 Material properties fc——the design value of concrete compressive strength; f1——the design value of the axial tensile strength of concrete; fy, ——the design values of the tensile and compressive strength of regular reinforcement; fpy——the design value of the tensile strength of prestressed reinforcement; fyv——the design value of the tensile strength of hooped reinforcement. 2.2.2 Actions and effects N——the design value of the axial pressure of column under the combination of earthquake action; V——the design value of the shear force under the combination of earthquake action; Npe——the total effective pre-applied force of the prestressed reinforcements. 2.2.3 Geometric parameters Aa, ——the cross-sectional area of nonprestressed reinforcements in tensile region and compressive region; Ap——the cross-sectional area of prestressed reinforcements in tensile region; Asvj——the total cross-sectional area of the hooped reinforcements in one same sectional recalculation direction within the effective recalculation width of the core area; b——the width of rectangular section, and the width of the web plate of T-shape and I-shape sections. h——the height of the section; ho——the effective height of the section; hp——the effective distance from the point of force concurrence of the longitudinal tensioned prestressed reinforcements to the compression flange of the section of girder; hδ——the effective distance from the point of force concurrence of the longitudinal tensioned nonprestressed reinforcements to the compression flange of the section of girder; bc, hc——the width and height of column section; bj, hj——the effective recalculating width and height of the section in the core area of node; bd——the effective width of flat backing plate; lo——the theoretical span; x——the height of the compressive region of concrete; laE——the minimum anchorage length of longitudinal tension reinforcement with the consideration of antiseismic requirement; s——the space between hooped reinforcements; 2.2.4 Calculation factors and others α——the value of the horizontal seismic influence factor; αmax——the maximum value of the horizontal seismic influence factor; γp——the partial safety factor of prestress; γRE——the antiseismic adjustment factor of the bearing capacity; εapu——the total strain of prestressed reinforcement-anchorage assembly parts when they reach the actual ultimate tension. ηa——the efficiency factor of anchorage device measured in the static test of prestressed reinforcement-anchorage assembly parts; λ——the strength ratio of prestress; βc——the influence factor of concrete strength; ρ——the reinforcement ratio of longitudinal tension reinforcements; ηj——the restraining influence factor of perpendicular girders; λNp——the axial compression ratio of the prestressed concrete column. T——the natural vibration period of structure; Tg——the eigenperiod of the site. 3 General Provisions of Seismic Design 3.1 Earthquake Action and Structural Seismic Checking 3.1.1 The seismic influence factor of the building structures shall be determined according to the intensity, site category, design earthquake classification and the natural vibration period of structure as well as the damping ratio. And the maximum value of the horizontal seismic influence factor shall be adopted in accordance with those specified in Table 3.1.1-1; the eigenperiod shall be adopted accord
1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 General Provisions of Seismic Design 3.1 Earthquake Action and Structural Seismic Checking 3.2 General Provisions of Design 3.3 Materials and Anchorage Devices 4 Prestressed Concrete Frame and Portal 4.1 General Provisions 4.2 Prestressed Concrete Frame-beam 4.3 Prestressed Concrete Frame Frame-column 4.4 Joint of Prestressed Concrete Frame 4.5 Prestressed Concrete Portal Structure 5 Prestressed Concrete Slab-column Structure 5.1 General Provisions of Design 5.2 Calculation Requirements Explanation of Wording in this Standard
JGJ 140-2004 is referred in:
*DBJ 15-95-2013 Technical specification for cast-in-situ concrete hollow floor structure
*JGJ 369-2016 Code for Design of Prestressed Concrete Structures
Code of China
Standard
JGJ 140-2004  Specification for Seismic Design of Prestressed Concrete Structures (English Version)
Standard No.JGJ 140-2004
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on2004-5-1
Deliveryvia email in 1 business day
Detail of JGJ 140-2004
Standard No.
JGJ 140-2004
English Name
Specification for Seismic Design of Prestressed Concrete Structures
Chinese Name
预应力混凝土结构抗震设计规程
Chinese Classification
301
Professional Classification
JG
ICS Classification
Issued by
MOC
Issued on
2004-01-29
Implemented on
2004-5-1
Status
superseded
Superseded by
JGJ/T 140-2019 Standard for seismic design of prestressed concrete structures
Superseded on
2020-2-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
JGJ 140-2004, JGJ/T 140-2004, JGJT 140-2004, JGJ140-2004, JGJ 140, JGJ140, JGJ/T140-2004, JGJ/T 140, JGJ/T140, JGJT140-2004, JGJT 140, JGJT140
Introduction of JGJ 140-2004
1 General Provisions 1.0.1 This standard was formulated to implement the guideline on prevention first in seismic operation, lighten the seismic destructiveness of the prestressed concrete building structures after the seismic protection, avoid the casualties and reduce the economic loss. 1.0.2 This standard is applicable to the seismic design of such building structures as the cast-in-situ post-tensioned prestressed concrete frame and slab-column in the areas with seismic protection intensity of 6~8 magnitude; however, the seismic design of the prestressed concrete structures in the areas with seismic protection intensity of 9 magnitude shall be with full references and adopted with reliable measures. 1.0.3 The seismic design of the prestressed concrete building structure shall not only comply with this standard, but also shall comply with those specified in the current relevant national compulsory standards. 2 Terms and Symbols 2.1 Terms 2.1.1 Damping ratio It is the ratio of the actual resistance of damped vibration and the resistance required for generating the critical damping. 2.1.2 It is the ratio of axial compressive force to axial compressive ultimate capacity of section under combination of earthquake action It is the ratio between the design value of the axial pressure of concrete column under the combination of the earthquake action and the arithmetic product of the bulk cross-section area of column with the design value of concrete compressive strength; as for the prestressed concrete column, it shall be taken as the design axial force value of the combination in which the prestress action participates. 2.1.3 Post-tensioned bonded prestressed concrete structure It is the bonded concrete structure by stretching and anchoring the prestressed reinforcements to establish prestress after the concrete has been hardened, and then grouting in the pipe, for instance, prestressed concrete frame and portal. 2.1.4 Unbonded prestressed concrete structure It is the post-stressed concrete structure that is allocated with such prestressed reinforcements with paint coat and cladding but does not bond with concrete. 2.2 Symbols 2.2.1 Material properties fc——the design value of concrete compressive strength; f1——the design value of the axial tensile strength of concrete; fy, ——the design values of the tensile and compressive strength of regular reinforcement; fpy——the design value of the tensile strength of prestressed reinforcement; fyv——the design value of the tensile strength of hooped reinforcement. 2.2.2 Actions and effects N——the design value of the axial pressure of column under the combination of earthquake action; V——the design value of the shear force under the combination of earthquake action; Npe——the total effective pre-applied force of the prestressed reinforcements. 2.2.3 Geometric parameters Aa, ——the cross-sectional area of nonprestressed reinforcements in tensile region and compressive region; Ap——the cross-sectional area of prestressed reinforcements in tensile region; Asvj——the total cross-sectional area of the hooped reinforcements in one same sectional recalculation direction within the effective recalculation width of the core area; b——the width of rectangular section, and the width of the web plate of T-shape and I-shape sections. h——the height of the section; ho——the effective height of the section; hp——the effective distance from the point of force concurrence of the longitudinal tensioned prestressed reinforcements to the compression flange of the section of girder; hδ——the effective distance from the point of force concurrence of the longitudinal tensioned nonprestressed reinforcements to the compression flange of the section of girder; bc, hc——the width and height of column section; bj, hj——the effective recalculating width and height of the section in the core area of node; bd——the effective width of flat backing plate; lo——the theoretical span; x——the height of the compressive region of concrete; laE——the minimum anchorage length of longitudinal tension reinforcement with the consideration of antiseismic requirement; s——the space between hooped reinforcements; 2.2.4 Calculation factors and others α——the value of the horizontal seismic influence factor; αmax——the maximum value of the horizontal seismic influence factor; γp——the partial safety factor of prestress; γRE——the antiseismic adjustment factor of the bearing capacity; εapu——the total strain of prestressed reinforcement-anchorage assembly parts when they reach the actual ultimate tension. ηa——the efficiency factor of anchorage device measured in the static test of prestressed reinforcement-anchorage assembly parts; λ——the strength ratio of prestress; βc——the influence factor of concrete strength; ρ——the reinforcement ratio of longitudinal tension reinforcements; ηj——the restraining influence factor of perpendicular girders; λNp——the axial compression ratio of the prestressed concrete column. T——the natural vibration period of structure; Tg——the eigenperiod of the site. 3 General Provisions of Seismic Design 3.1 Earthquake Action and Structural Seismic Checking 3.1.1 The seismic influence factor of the building structures shall be determined according to the intensity, site category, design earthquake classification and the natural vibration period of structure as well as the damping ratio. And the maximum value of the horizontal seismic influence factor shall be adopted in accordance with those specified in Table 3.1.1-1; the eigenperiod shall be adopted accord
Contents of JGJ 140-2004
1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 General Provisions of Seismic Design 3.1 Earthquake Action and Structural Seismic Checking 3.2 General Provisions of Design 3.3 Materials and Anchorage Devices 4 Prestressed Concrete Frame and Portal 4.1 General Provisions 4.2 Prestressed Concrete Frame-beam 4.3 Prestressed Concrete Frame Frame-column 4.4 Joint of Prestressed Concrete Frame 4.5 Prestressed Concrete Portal Structure 5 Prestressed Concrete Slab-column Structure 5.1 General Provisions of Design 5.2 Calculation Requirements Explanation of Wording in this Standard
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JGJ 140-2004, JGJ/T 140-2004, JGJT 140-2004, JGJ140-2004, JGJ 140, JGJ140, JGJ/T140-2004, JGJ/T 140, JGJ/T140, JGJT140-2004, JGJT 140, JGJT140