2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JGJ/T 163-2008
JGJ/T 163-2008   Code for lighting design of urban nightscape (English Version)
Standard No.: JGJ/T 163-2008 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:2009-5-1 Delivery: via email in 1 business day

→ → →

,,2009-5-1,141137605163447E4B1497B4B399A
Standard No.: JGJ/T 163-2008
English Name: Code for lighting design of urban nightscape
Chinese Name: 城市夜景照明设计规范
Chinese Classification: P50    Urban and rural planning
Professional Classification: JG    Professional Standard - Building
Source Content Issued by: MOHURD
Issued on: 2008-11-4
Implemented on: 2009-5-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated with a view to implementing national laws and regulations as well as technical and economic policies in urban nightscape lighting design, shaping the urban image in the night, increasing urban charming, enriching people's activities at night, achieving advanced technology, economic and rational, energy conservation, environment protection, safe application, convenient maintenance and management as well as implementing green lights. 1.0.2 This code is applicable to the nightscape lighting design of urban constructed, renovated and expanded, buildings, structures, particular landscape elements, commercial pedestrian streets, squares, parks, advertisement, signs, etc. 1.0.3 In addition to this code, the urban nightscape lighting design shall comply with those specified in the relevant current standards of China.
Contents 1 General Provisions 2 Terms 3 Basic Requirements 3.1 Design Principles 3.2 Lighting Sources and the Selection of Their Electric Accessories 3.3 Selection of Lighting Luminaire 4 Lighting Evaluation Index 4.1 Illuminance or Luminance 4.2 Colour 4.3 Uniformity, Contrast and Modeling 4.4 Glare Limit 5 Lighting Design 5.1 Buildings 5.2 Structures and Particular Landscape Elements 5.3 Commercial Pedestrian Street 5.4 Squares 5.5 Parks 5.6 Advertisement and Sign 6 Lighting Energy Saving 6.1 Lighting Energy Saving Measures 6.2 Lighting Power Density 7 Light Pollution Limits 8 Lighting Power Supply, Distribution and Safety 8.1 Lighting Power Supply and Distribution 8.2 Lighting Control 8.3 Safety Protection and Earthing Appendix A Urban Scale and Division of Environment Zones Appendix B Calculation, Measurement and Application of Semicylinder Illuminance Appendix C Zone Division of Paddling Pool and Fountain Zone Explanation of Wording in This Code
JGJ/T 163-2008 is referred in:
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50908-2013 Evaluation Standard for Green Office Building
* GB/T 50908-2013 Evaluation Standard for Green Office Building
* GB 50189-2015 Design Standard for Energy Efficiency of Public Buildings
* GB/T 51165-2016 Assessment Standard For Green Building
*GB/T 50378-2019 Assessment standard for green building
Code of China
Standard
JGJ/T 163-2008  Code for lighting design of urban nightscape (English Version)
Standard No.JGJ/T 163-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on2009-5-1
Deliveryvia email in 1 business day
Detail of JGJ/T 163-2008
Standard No.
JGJ/T 163-2008
English Name
Code for lighting design of urban nightscape
Chinese Name
城市夜景照明设计规范
Chinese Classification
P50
Professional Classification
JG
ICS Classification
Issued by
MOHURD
Issued on
2008-11-4
Implemented on
2009-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
JGJ/T 163-2008, JGJ 163-2008, JGJT 163-2008, JGJ/T163-2008, JGJ/T 163, JGJ/T163, JGJ163-2008, JGJ 163, JGJ163, JGJT163-2008, JGJT 163, JGJT163
Introduction of JGJ/T 163-2008
1 General Provisions 1.0.1 This code is formulated with a view to implementing national laws and regulations as well as technical and economic policies in urban nightscape lighting design, shaping the urban image in the night, increasing urban charming, enriching people's activities at night, achieving advanced technology, economic and rational, energy conservation, environment protection, safe application, convenient maintenance and management as well as implementing green lights. 1.0.2 This code is applicable to the nightscape lighting design of urban constructed, renovated and expanded, buildings, structures, particular landscape elements, commercial pedestrian streets, squares, parks, advertisement, signs, etc. 1.0.3 In addition to this code, the urban nightscape lighting design shall comply with those specified in the relevant current standards of China.
Contents of JGJ/T 163-2008
Contents 1 General Provisions 2 Terms 3 Basic Requirements 3.1 Design Principles 3.2 Lighting Sources and the Selection of Their Electric Accessories 3.3 Selection of Lighting Luminaire 4 Lighting Evaluation Index 4.1 Illuminance or Luminance 4.2 Colour 4.3 Uniformity, Contrast and Modeling 4.4 Glare Limit 5 Lighting Design 5.1 Buildings 5.2 Structures and Particular Landscape Elements 5.3 Commercial Pedestrian Street 5.4 Squares 5.5 Parks 5.6 Advertisement and Sign 6 Lighting Energy Saving 6.1 Lighting Energy Saving Measures 6.2 Lighting Power Density 7 Light Pollution Limits 8 Lighting Power Supply, Distribution and Safety 8.1 Lighting Power Supply and Distribution 8.2 Lighting Control 8.3 Safety Protection and Earthing Appendix A Urban Scale and Division of Environment Zones Appendix B Calculation, Measurement and Application of Semicylinder Illuminance Appendix C Zone Division of Paddling Pool and Fountain Zone Explanation of Wording in This Code
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JGJ/T 163-2008, JGJ 163-2008, JGJT 163-2008, JGJ/T163-2008, JGJ/T 163, JGJ/T163, JGJ163-2008, JGJ 163, JGJ163, JGJT163-2008, JGJT 163, JGJT163