JJF 1101-2003   Calibration Specification for the Equipment of the Environmental Testing for Temperature and Humidity (English Version)
Standard No.: JJF 1101-2003 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5000 words Translation Price(USD):120.0 remind me the price change

Email:

Implemented on:2003-9-12 Delivery: via email in 1 business day

→ → →

,2020-3-5,2003-9-12,1411374195922039B55661B5267F5
Standard No.: JJF 1101-2003
English Name: Calibration Specification for the Equipment of the Environmental Testing for Temperature and Humidity
Chinese Name: 环境试验设备温度、湿度校准规范
Chinese Classification: A54    Thermal Measurement
Professional Classification: JJ    Metering
Source Content Issued by: AQSIQ
Issued on: 2003-05-12
Implemented on: 2003-9-12
Status: superseded
Superseded by:JJF 1101-2019 Calibration Specification of Environmental Testing Equipment for Temperature and Humidity Parameters
Superseded on:2020-3-5
Target Language: English
File Format: PDF
Word Count: 5000 words
Translation Price(USD): 120.0
Delivery: via email in 1 business day
Calibration Specification for the Equipment of the Environmental Testing for Temperature and Humidity 环境试验设备温度、湿度校准规范 1 Scope This specification is applicable to the calibration for metrological performance of equipment of the environmental testing for temperature and humidity (hereinafter referred to as environmental testing equipment). Other similar equipment may also be calibrated by reference to this specification. 2 References GB/T 2423.4-1993 Basic Environmental Testing Procedures for Electric and Electronic Products - Test Db: Damp Heat, Cyclic GB 6999-1986 Relative Humidity Tables for Environmental Test JJF 1071-2000 The Rules for Drafting National Calibration Specification While using this specification, current valid editions of such documents shall be applied. 3 Terms 3.1 Temperature Deviation The difference between the displayed temperature average of the environmental testing equipment under stable state and the measured temperature average of the center point in work space. 3.2 Relative Humidity Deviation The difference between the displayed relative humidity average of the environmental testing equipment under stable state and the measured relative humidity average of the center point in work space. 3.3 Nominal Value The parameter specified according to the testing method requirements or that predetermined as required when calibrating the equipment of the environmental testing for temperature and humidity. 4 Metrological Performance See Table 1 for the deviation, uniformity and fluctuation respectively for the temperature and relative humidity. 5 Calibration Conditions 5.1 Environmental Conditions 5.1.1 Temperature: (15~35)℃ Humidity: (30~85)%RH Atmospheric pressure: (86~106)kPa 5.1.2 Loading conditions Generally, calibration is carried out under no-load condition; where required by the user, it may be carried out under loaded condition. However, the loading condition shall be descripted. Table 1 Equipment name Temperature testing equipment Damp heat testing equipment Alternating damp heat equipment Temperature and humidity range (0~100) ℃ (-60~0)℃ (100~200)℃ (200~300) ℃ (10~60)℃ (20~100) %RH (10~60)℃ (20~100) %RH (20~60)℃ (80~100) %RH Temperature deviation ±1.0℃ ±2℃ ±3℃ ±2℃ ±2℃ ±2℃ Humidity deviation - - - +2 %RH -3 ±5%RH +2 %RH -3 Uniformity Temperature 1.0℃ 2℃ 3℃ 1℃ 2℃ 2℃ Humidity - - - 3%RH 5%RH 3%RH Fluctuation Temperature ±0.5℃ ±0.5℃ ±2℃ ±0.5℃ ±1℃ ±1℃ Humidity - - - ±2%RH ±3%RH ±3%RH Notes: 1. The alternating capacity of alternating damp heat equipment shall be inspected. 2. For the temperature and damp heat testing equipment with metrological performance otherwise specified, calibration shall be carried out according to the requirements of relevant technical documents. 5.1.3 Other conditions: the equipment shall be free from strong vibration and corrosive gas at its surrounding, and shall be free from being affected by other cold and heat sources. 5.2 Standard Instrument and Other Equipment 5.2.1 Temperature measurement standard Temperature measurement is composed of temperature sensor (generally, four-wire system platinum thermistor is adopted) and displayer, and the time constant shall be less than 15s. 5.2.2 Humidity measurement standard The following instruments may be adopted for humidity measurement: Digital ventilated psychrometer and gas-pressure meter (the ventilation speed shall be greater than 2.5m/s) Digital hygrometer (only used for humidity field without alternation) Dry and wet bulb thermometers① (applicable to the measurement of relative humidity and uniformity under uniform wind speed) 6 Calibration Items and Methods 6.1 Calibration Items See Table 2 for the calibration items. Note: the manufacture method of ① dry and wet bulb thermometers shall meet the requirements of Appendix C.
1 Scope 2 References 3 Terms 3.1 Temperature Deviation 3.2 Relative Humidity Deviation 3.3 Nominal Value 4 Metrological Performance 5 Calibration Conditions 5.1 Environmental Conditions 5.2 Standard Instrument and Other Equipment 6 Calibration Items and Methods 6.1 Calibration Items 6.2 Calibration Methods 6.3 Data Processing 7 Calibration Result Expression 8 Recalibration Interval Appendix A Reference Format for Calibration Record of Environmental Testing Equipment Appendix B Reference Format for Calibration Result of Environmental Testing Equipment Appendix C Relative Humidity Measurement with Dry and Wet Bulb Method Appendix D Uncertainty Analysis for Temperature Deviation Calibration Result of Environmental Testing Equipment Appendix E Uncertainty Analysis for Relative Humidity Deviation Calibration Result of Environmental Testing Equipment
Code of China
Standard
JJF 1101-2003  Calibration Specification for the Equipment of the Environmental Testing for Temperature and Humidity (English Version)
Standard No.JJF 1101-2003
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)120.0
Implemented on2003-9-12
Deliveryvia email in 1 business day
Detail of JJF 1101-2003
Standard No.
JJF 1101-2003
English Name
Calibration Specification for the Equipment of the Environmental Testing for Temperature and Humidity
Chinese Name
环境试验设备温度、湿度校准规范
Chinese Classification
A54
Professional Classification
JJ
ICS Classification
Issued by
AQSIQ
Issued on
2003-05-12
Implemented on
2003-9-12
Status
superseded
Superseded by
JJF 1101-2019 Calibration Specification of Environmental Testing Equipment for Temperature and Humidity Parameters
Superseded on
2020-3-5
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
120.0
Keywords
JJF 1101-2003, JJF/T 1101-2003, JJFT 1101-2003, JJF1101-2003, JJF 1101, JJF1101, JJF/T1101-2003, JJF/T 1101, JJF/T1101, JJFT1101-2003, JJFT 1101, JJFT1101
Introduction of JJF 1101-2003
Calibration Specification for the Equipment of the Environmental Testing for Temperature and Humidity 环境试验设备温度、湿度校准规范 1 Scope This specification is applicable to the calibration for metrological performance of equipment of the environmental testing for temperature and humidity (hereinafter referred to as environmental testing equipment). Other similar equipment may also be calibrated by reference to this specification. 2 References GB/T 2423.4-1993 Basic Environmental Testing Procedures for Electric and Electronic Products - Test Db: Damp Heat, Cyclic GB 6999-1986 Relative Humidity Tables for Environmental Test JJF 1071-2000 The Rules for Drafting National Calibration Specification While using this specification, current valid editions of such documents shall be applied. 3 Terms 3.1 Temperature Deviation The difference between the displayed temperature average of the environmental testing equipment under stable state and the measured temperature average of the center point in work space. 3.2 Relative Humidity Deviation The difference between the displayed relative humidity average of the environmental testing equipment under stable state and the measured relative humidity average of the center point in work space. 3.3 Nominal Value The parameter specified according to the testing method requirements or that predetermined as required when calibrating the equipment of the environmental testing for temperature and humidity. 4 Metrological Performance See Table 1 for the deviation, uniformity and fluctuation respectively for the temperature and relative humidity. 5 Calibration Conditions 5.1 Environmental Conditions 5.1.1 Temperature: (15~35)℃ Humidity: (30~85)%RH Atmospheric pressure: (86~106)kPa 5.1.2 Loading conditions Generally, calibration is carried out under no-load condition; where required by the user, it may be carried out under loaded condition. However, the loading condition shall be descripted. Table 1 Equipment name Temperature testing equipment Damp heat testing equipment Alternating damp heat equipment Temperature and humidity range (0~100) ℃ (-60~0)℃ (100~200)℃ (200~300) ℃ (10~60)℃ (20~100) %RH (10~60)℃ (20~100) %RH (20~60)℃ (80~100) %RH Temperature deviation ±1.0℃ ±2℃ ±3℃ ±2℃ ±2℃ ±2℃ Humidity deviation - - - +2 %RH -3 ±5%RH +2 %RH -3 Uniformity Temperature 1.0℃ 2℃ 3℃ 1℃ 2℃ 2℃ Humidity - - - 3%RH 5%RH 3%RH Fluctuation Temperature ±0.5℃ ±0.5℃ ±2℃ ±0.5℃ ±1℃ ±1℃ Humidity - - - ±2%RH ±3%RH ±3%RH Notes: 1. The alternating capacity of alternating damp heat equipment shall be inspected. 2. For the temperature and damp heat testing equipment with metrological performance otherwise specified, calibration shall be carried out according to the requirements of relevant technical documents. 5.1.3 Other conditions: the equipment shall be free from strong vibration and corrosive gas at its surrounding, and shall be free from being affected by other cold and heat sources. 5.2 Standard Instrument and Other Equipment 5.2.1 Temperature measurement standard Temperature measurement is composed of temperature sensor (generally, four-wire system platinum thermistor is adopted) and displayer, and the time constant shall be less than 15s. 5.2.2 Humidity measurement standard The following instruments may be adopted for humidity measurement: Digital ventilated psychrometer and gas-pressure meter (the ventilation speed shall be greater than 2.5m/s) Digital hygrometer (only used for humidity field without alternation) Dry and wet bulb thermometers① (applicable to the measurement of relative humidity and uniformity under uniform wind speed) 6 Calibration Items and Methods 6.1 Calibration Items See Table 2 for the calibration items. Note: the manufacture method of ① dry and wet bulb thermometers shall meet the requirements of Appendix C.
Contents of JJF 1101-2003
1 Scope 2 References 3 Terms 3.1 Temperature Deviation 3.2 Relative Humidity Deviation 3.3 Nominal Value 4 Metrological Performance 5 Calibration Conditions 5.1 Environmental Conditions 5.2 Standard Instrument and Other Equipment 6 Calibration Items and Methods 6.1 Calibration Items 6.2 Calibration Methods 6.3 Data Processing 7 Calibration Result Expression 8 Recalibration Interval Appendix A Reference Format for Calibration Record of Environmental Testing Equipment Appendix B Reference Format for Calibration Result of Environmental Testing Equipment Appendix C Relative Humidity Measurement with Dry and Wet Bulb Method Appendix D Uncertainty Analysis for Temperature Deviation Calibration Result of Environmental Testing Equipment Appendix E Uncertainty Analysis for Relative Humidity Deviation Calibration Result of Environmental Testing Equipment