JJG 12-1998   Methane-Carbon Monoxide Detector (English Version)
Standard No.: JJG 12-1998 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 2500 words Translation Price(USD):50.0 remind me the price change

Email:

Implemented on:1998-7-1 Delivery: via email in 1 business day

→ → →

,,1998-7-1,14113733075936683FBDFD6BF1078
Standard No.: JJG 12-1998
English Name: Methane-Carbon Monoxide Detector
Chinese Name: 甲烷-一氧化碳检测报警仪
Professional Classification: JJ    Metering
Issued on: 1998-3-16
Implemented on: 1998-7-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 2500 words
Translation Price(USD): 50.0
Delivery: via email in 1 business day
This verification regulation is applicable to the verification for all new-built, in-use or repaired portable methane-carbon monoxide detectors (hereinafter referred to as detector). I Overview The detector is mainly used for the measurement and warning of methane and carbon monoxide concentration below the coalmine well. The detector is composed of methane sensors, carbon monoxide sensors and secondary meter. II Technical Requirements 1 Appearance and Power-on Inspection 1.1 Perfect appearance and complete structure; the instrument name, type, name of manufacturer, date of production, serial number, explosion protection mark and safety mark, and so on shall be complete and clear. 1.2 The detector must meet the explosion-proof requirements specified in GB 3836-1983 "Electrical Apparatus for Explosive Atmosphere". 1.3 The new exfactory detectors shall have complete auxiliaries accompanied by manufacturer's operation instruction and products' qualification certificate. 1.4 Reliable linkage of the detector, each motion component of which shall be able to be adjusted normally; the button to detect the interconversion between methane and carbon monoxide or the function to detect the automatic switching shall be equipped with. 1.5 After the detector is energized, all parts shall be able to work normally with correspondingly clear and stable display of each display part. There shall be obvious differences between methane detection state and carbon monoxide detection state. 1.6 Supply voltage shall meet the work requirements of detectors and have undervoltage indication. 2 Intrinsic Error The difference between the indicating value and standard value of the detector shall not exceed the requirements in Table 1 and Table 2 at the normal working condition.
I Overview II Technical Requirements III Verification Condition IV Verification Items and Methods V Treatment of the verification results and verification periods Appendix
Code of China
Standard
JJG 12-1998  Methane-Carbon Monoxide Detector (English Version)
Standard No.JJG 12-1998
Statusvalid
LanguageEnglish
File FormatPDF
Word Count2500 words
Price(USD)50.0
Implemented on1998-7-1
Deliveryvia email in 1 business day
Detail of JJG 12-1998
Standard No.
JJG 12-1998
English Name
Methane-Carbon Monoxide Detector
Chinese Name
甲烷-一氧化碳检测报警仪
Chinese Classification
Professional Classification
JJ
ICS Classification
Issued by
Issued on
1998-3-16
Implemented on
1998-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
2500 words
Price(USD)
50.0
Keywords
JJG 12-1998, JJG/T 12-1998, JJGT 12-1998, JJG12-1998, JJG 12, JJG12, JJG/T12-1998, JJG/T 12, JJG/T12, JJGT12-1998, JJGT 12, JJGT12
Introduction of JJG 12-1998
This verification regulation is applicable to the verification for all new-built, in-use or repaired portable methane-carbon monoxide detectors (hereinafter referred to as detector). I Overview The detector is mainly used for the measurement and warning of methane and carbon monoxide concentration below the coalmine well. The detector is composed of methane sensors, carbon monoxide sensors and secondary meter. II Technical Requirements 1 Appearance and Power-on Inspection 1.1 Perfect appearance and complete structure; the instrument name, type, name of manufacturer, date of production, serial number, explosion protection mark and safety mark, and so on shall be complete and clear. 1.2 The detector must meet the explosion-proof requirements specified in GB 3836-1983 "Electrical Apparatus for Explosive Atmosphere". 1.3 The new exfactory detectors shall have complete auxiliaries accompanied by manufacturer's operation instruction and products' qualification certificate. 1.4 Reliable linkage of the detector, each motion component of which shall be able to be adjusted normally; the button to detect the interconversion between methane and carbon monoxide or the function to detect the automatic switching shall be equipped with. 1.5 After the detector is energized, all parts shall be able to work normally with correspondingly clear and stable display of each display part. There shall be obvious differences between methane detection state and carbon monoxide detection state. 1.6 Supply voltage shall meet the work requirements of detectors and have undervoltage indication. 2 Intrinsic Error The difference between the indicating value and standard value of the detector shall not exceed the requirements in Table 1 and Table 2 at the normal working condition.
Contents of JJG 12-1998
I Overview II Technical Requirements III Verification Condition IV Verification Items and Methods V Treatment of the verification results and verification periods Appendix
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JJG 12-1998, JJG/T 12-1998, JJGT 12-1998, JJG12-1998, JJG 12, JJG12, JJG/T12-1998, JJG/T 12, JJG/T12, JJGT12-1998, JJGT 12, JJGT12