2025-7-20 18.97.9.172
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JJG 577-2012
JJG 577-2012   Diaphragm Gas Meters (English Version)
Standard No.: JJG 577-2012 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4000 words Price(USD):80.0 remind me the price change

Email:

Implemented on:2013-3-3 Delivery: via email in 1 business day
,,
Standard No.: JJG 577-2012
English Name: Diaphragm Gas Meters
Chinese Name: 膜式燃气表
Professional Classification: JJ    Metering
Issued by: AQSIQ
Issued on: 2012-9-3
Implemented on: 2013-3-3
Status: valid
Superseding:JJG 577-2005 Verification Regulation of Diaphragm Gas Meters
Language: English
File Format: PDF
Word Count: 4000 words
Price(USD): 80.0
Delivery: via email in 1 business day
1 Scope This regulation is applicable to initial verification, subsequent verification and in-use inspection of diaphragm gas meters (hereinafter referred as gas meters). 2 Normative References The following documents are referenced in this regulation: JJF 1001-2011 General Terms in Metrology and Their Definitions GB/T 6968-2011 Diaphragm Gas Meters OIML Rl37-1&2: 2012 Gas Meters 0IML D11:2004 General Requirements for Electronic Measuring Instrument EN 1359:1998+A1:2006 Diaphragm Gas Meters For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. 3 Terms and Measuring Units 3.1 Terms 3.1.1 Maximum flow-rate qmax The upper limit of flow-rate of gas meter complying with metering performance. 3.1.2 Minimum flow-rate qmin The lower limit of flow-rate of gas meter complying with metering performance. 3.1.3 Transitional flow-rate qt The flow-rate between the maximum and minimum flow-rate, dividing the flow-rate range of gas meter into "high area" and "low area". Both high area and low area are subject to corresponding maximum permissible error. qt equals to 0.1qmax. 3.1.4 Flow-rate range The range limited by the maximum and minimum flow-rate complying with the metering performance of gas meter. 3.1.5 Maximum operating pressure pmax The upper limit of gas meter operating pressure. 3.1.6 Pressure loss △p The average pressure drop between air inlet and air outlet under maximum flow-rate. 3.1.7 Integrating value Q
Introduction I 1 Scope 2 Normative References 3 Terms and Measuring Units 3.1 Terms 3.2 Measuring Units 4 General 4.1 Principle and Structure 4.2 Purpose 5 Measuring Performance Requirements 6 General Technical Requirements 6.1 Nameplate and Marking 6.2 Appearance 6.3 Flow-rate Range 6.4 Indicating Device 6.5 Sealing 6.6 Pressure Loss 6.7 Ancillary Devices 6.8 Safety Performance 7 Control of Measuring Tools 7.1 Verification Conditions 7.2 Verification Items 7.3 Verification Methods 7.4 Verification Result Treatment 7.5 Verification Cycle Appendix A Function Test for Ancillary Devices of Gas Meters Appendix B Information and Format for Inside Page of Verification Certificate/Verification Result Notice
Referred in JJG 577-2012:
* JJF 1001-2011 General Terms in Metrology and Their Definitions
* GB/T 6968-2011 Diaphragm gas meters
Code of China
Standard
JJG 577-2012  Diaphragm Gas Meters (English Version)
Standard No.JJG 577-2012
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)80.0
Implemented on2013-3-3
Deliveryvia email in 1 business day
Detail of JJG 577-2012
Standard No.
JJG 577-2012
English Name
Diaphragm Gas Meters
Chinese Name
膜式燃气表
Chinese Classification
Professional Classification
JJ
ICS Classification
Issued by
AQSIQ
Issued on
2012-9-3
Implemented on
2013-3-3
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JJG 577-2005 Verification Regulation of Diaphragm Gas Meters
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
80.0
Keywords
JJG 577-2012, JJG/T 577-2012, JJGT 577-2012, JJG577-2012, JJG 577, JJG577, JJG/T577-2012, JJG/T 577, JJG/T577, JJGT577-2012, JJGT 577, JJGT577
Introduction of JJG 577-2012
1 Scope This regulation is applicable to initial verification, subsequent verification and in-use inspection of diaphragm gas meters (hereinafter referred as gas meters). 2 Normative References The following documents are referenced in this regulation: JJF 1001-2011 General Terms in Metrology and Their Definitions GB/T 6968-2011 Diaphragm Gas Meters OIML Rl37-1&2: 2012 Gas Meters 0IML D11:2004 General Requirements for Electronic Measuring Instrument EN 1359:1998+A1:2006 Diaphragm Gas Meters For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. 3 Terms and Measuring Units 3.1 Terms 3.1.1 Maximum flow-rate qmax The upper limit of flow-rate of gas meter complying with metering performance. 3.1.2 Minimum flow-rate qmin The lower limit of flow-rate of gas meter complying with metering performance. 3.1.3 Transitional flow-rate qt The flow-rate between the maximum and minimum flow-rate, dividing the flow-rate range of gas meter into "high area" and "low area". Both high area and low area are subject to corresponding maximum permissible error. qt equals to 0.1qmax. 3.1.4 Flow-rate range The range limited by the maximum and minimum flow-rate complying with the metering performance of gas meter. 3.1.5 Maximum operating pressure pmax The upper limit of gas meter operating pressure. 3.1.6 Pressure loss △p The average pressure drop between air inlet and air outlet under maximum flow-rate. 3.1.7 Integrating value Q
Contents of JJG 577-2012
Introduction I 1 Scope 2 Normative References 3 Terms and Measuring Units 3.1 Terms 3.2 Measuring Units 4 General 4.1 Principle and Structure 4.2 Purpose 5 Measuring Performance Requirements 6 General Technical Requirements 6.1 Nameplate and Marking 6.2 Appearance 6.3 Flow-rate Range 6.4 Indicating Device 6.5 Sealing 6.6 Pressure Loss 6.7 Ancillary Devices 6.8 Safety Performance 7 Control of Measuring Tools 7.1 Verification Conditions 7.2 Verification Items 7.3 Verification Methods 7.4 Verification Result Treatment 7.5 Verification Cycle Appendix A Function Test for Ancillary Devices of Gas Meters Appendix B Information and Format for Inside Page of Verification Certificate/Verification Result Notice
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
JJG 577-2012, JJG/T 577-2012, JJGT 577-2012, JJG577-2012, JJG 577, JJG577, JJG/T577-2012, JJG/T 577, JJG/T577, JJGT577-2012, JJGT 577, JJGT577