2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JJG 971-2019
JJG 971-2019   Liquid Level Gauges (English Version)
Standard No.: JJG 971-2019 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):255.0 remind me the price change

Email:

Implemented on:2020-3-31 Delivery: via email in 1 business day

→ → →

,,2020-3-31,ED7917246AF77BD31582813342150
Standard No.: JJG 971-2019
English Name: Liquid Level Gauges
Chinese Name: 液位计检定规程
Professional Classification: JJ    Metering
Source Content Issued by: SAMR
Issued on: 2019-12-31
Implemented on: 2020-3-31
Status: valid
Superseding:JJG 971-2002 Verification Regulation of the Liquid Level Measuring Devices
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 255.0
Delivery: via email in 1 business day
The National Pressure Measurement Technology Committee is in charge of the explanation of this regulation. Introduction JJF1001 General Terms in Metrology and Their Definitions, JJF 1002-2010 The Rules for Drafting National Metrological Verification Regulation, and JJF 1059.1-2012 Evaluation and Expression of Uncertainty in Measurement, etc., jointly constitute the basic series of specifications for the revision of this regulation. In addition to editorial changes, the following main technical changes have been made with respect to JJG 971-2002 Verification Regulation of the Liquid Level Measuring Devices: ——as required in JJF 1002-2010 that the Instruction shall be necessary, the Introduction is added. ——the terms are adjusted. The terms "set point error", "differential value" and "differential gap" are deleted, and the terms “level” and "liquid level gauge" are added. —— the application occasions of liquid level gauge are specified in the clause “General”. According to the current industry customs, four classification methods are proposed: liquid level measurement method, liquid level gauge measurement method, liquid level gauge installation method and liquid level gauge measurement principle. ——the content of type evaluation is deleted from the metrological performance requirements and general technical requirements. ——in the verification method, horizontal liquid level simulation verification device is put forward, and the basic technical requirements are proposed. New technical requirements are put forward for the original vertical liquid level verification device. ——the verification process and requirements of the two kinds of devices are specified in the verification method. ——the contents of Annex A "Type Identification or Prototype Test Items and Test Methods" in the original regulation are deleted. —— Annexes B and C of the original regulations are modified accordingly. The previous edition of this specification is as follows: ——JJG 971-2002 Verification regulation of liquid level gauges 1 Scope This regulation is applicable to the initial verification, subsequent verification and in-service inspection of liquid level gauges (excluding radiation level gauges). The calibration of level gauge can refer to this regulation. 2 Normative references The following document is referenced in this regulation: JJG 882 Pressure Transmitters For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. 3 Terms and meteorological units 3.1 Terms 3.1.1 level generic term of liquid level, material level and interface (position) is a parameter reflecting the total amount of objects and the surface characteristics of materials 3.1.2 liquid level gauge Instruments used to indicate and control liquid level and interface (position) in industrial process measurement and control system 3.2 Measurement unit The legal measurement unit used by level gauge is m (meter), or its decimal multiple unit: mm, cm, etc. 4 General Liquid level gauges are widely used to measure the internal liquid level or interface of tanks, kettles, towers, bottles, furnaces and canals in industrial processes. The liquid level measurement methods include visual method, manual measuring method, blowing method, force measuring method, pressure method, electrical characteristic method, reflection method, thermal method, radiation method, neutron method, etc. Liquid level gauges can be divided into contact type and non-contact type according to the measurement mode, can be divided into top-mounted, side-mounted, top-bottom, side-side, side-bottom, top-side and side-wall types according to installation modes, and can be divided into communication type, buoyancy type, pressure type, reflection type and electrical characteristic type according to the measuring principle. Communication type: (quartz) glass tube level gauge and glass plate level gauge; Buoyancy type: magnetic column (plate) level gauge, magnetostrictive level gauge, servo level gauge, steel strip level gauge, (electric) buoy level gauge and floating ball level gauge; Pressure type: static pressure (input) level gauge (transmitter) and differential pressure level gauge (transmitter); Reflection type: radar level gauge, ultrasonic level gauge and guided wave radar level gauge; Electrical characteristics: radio frequency admittance level gauge, capacitance level gauge, etc.
Introduction I 1 Scope 2 Normative references 3 Terms and meteorological units 4 General 5 Metrological performance requirements 6 General technical requirements 7 Control of metrological instruments Annex A Verification record format of liquid level gauge Annex B Inside page format of verification certificate/verification result notice
Referred in JJG 971-2019:
*JJG 882-2019 Pressure Transmitters
*GB 3565-2005 Safety requirements for bicycles
*TSG 21-2016/XG1-2020 Supervision Regulation on Safety Technology for Stationary Pressure Vessel,includes Amendment 1
*GB 14748-2006 Safety Requirements for Wheeled Child Conveyances
*GB 2763-2021 National Food Safety Standard-Maximum Residue Limits for Pesticides in Food
*GB/T 22849-2014 Knitted T-shirt
*FZ/T 81006-2017 Jeanswear
*GB 4943.1-2011 Information technology equipment -Safety - Part 1: General requirements
Code of China
Standard
JJG 971-2019  Liquid Level Gauges (English Version)
Standard No.JJG 971-2019
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)255.0
Implemented on2020-3-31
Deliveryvia email in 1 business day
Detail of JJG 971-2019
Standard No.
JJG 971-2019
English Name
Liquid Level Gauges
Chinese Name
液位计检定规程
Chinese Classification
Professional Classification
JJ
ICS Classification
Issued by
SAMR
Issued on
2019-12-31
Implemented on
2020-3-31
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JJG 971-2002 Verification Regulation of the Liquid Level Measuring Devices
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
255.0
Keywords
JJG 971-2019, JJG/T 971-2019, JJGT 971-2019, JJG971-2019, JJG 971, JJG971, JJG/T971-2019, JJG/T 971, JJG/T971, JJGT971-2019, JJGT 971, JJGT971
Introduction of JJG 971-2019
The National Pressure Measurement Technology Committee is in charge of the explanation of this regulation. Introduction JJF1001 General Terms in Metrology and Their Definitions, JJF 1002-2010 The Rules for Drafting National Metrological Verification Regulation, and JJF 1059.1-2012 Evaluation and Expression of Uncertainty in Measurement, etc., jointly constitute the basic series of specifications for the revision of this regulation. In addition to editorial changes, the following main technical changes have been made with respect to JJG 971-2002 Verification Regulation of the Liquid Level Measuring Devices: ——as required in JJF 1002-2010 that the Instruction shall be necessary, the Introduction is added. ——the terms are adjusted. The terms "set point error", "differential value" and "differential gap" are deleted, and the terms “level” and "liquid level gauge" are added. —— the application occasions of liquid level gauge are specified in the clause “General”. According to the current industry customs, four classification methods are proposed: liquid level measurement method, liquid level gauge measurement method, liquid level gauge installation method and liquid level gauge measurement principle. ——the content of type evaluation is deleted from the metrological performance requirements and general technical requirements. ——in the verification method, horizontal liquid level simulation verification device is put forward, and the basic technical requirements are proposed. New technical requirements are put forward for the original vertical liquid level verification device. ——the verification process and requirements of the two kinds of devices are specified in the verification method. ——the contents of Annex A "Type Identification or Prototype Test Items and Test Methods" in the original regulation are deleted. —— Annexes B and C of the original regulations are modified accordingly. The previous edition of this specification is as follows: ——JJG 971-2002 Verification regulation of liquid level gauges 1 Scope This regulation is applicable to the initial verification, subsequent verification and in-service inspection of liquid level gauges (excluding radiation level gauges). The calibration of level gauge can refer to this regulation. 2 Normative references The following document is referenced in this regulation: JJG 882 Pressure Transmitters For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. 3 Terms and meteorological units 3.1 Terms 3.1.1 level generic term of liquid level, material level and interface (position) is a parameter reflecting the total amount of objects and the surface characteristics of materials 3.1.2 liquid level gauge Instruments used to indicate and control liquid level and interface (position) in industrial process measurement and control system 3.2 Measurement unit The legal measurement unit used by level gauge is m (meter), or its decimal multiple unit: mm, cm, etc. 4 General Liquid level gauges are widely used to measure the internal liquid level or interface of tanks, kettles, towers, bottles, furnaces and canals in industrial processes. The liquid level measurement methods include visual method, manual measuring method, blowing method, force measuring method, pressure method, electrical characteristic method, reflection method, thermal method, radiation method, neutron method, etc. Liquid level gauges can be divided into contact type and non-contact type according to the measurement mode, can be divided into top-mounted, side-mounted, top-bottom, side-side, side-bottom, top-side and side-wall types according to installation modes, and can be divided into communication type, buoyancy type, pressure type, reflection type and electrical characteristic type according to the measuring principle. Communication type: (quartz) glass tube level gauge and glass plate level gauge; Buoyancy type: magnetic column (plate) level gauge, magnetostrictive level gauge, servo level gauge, steel strip level gauge, (electric) buoy level gauge and floating ball level gauge; Pressure type: static pressure (input) level gauge (transmitter) and differential pressure level gauge (transmitter); Reflection type: radar level gauge, ultrasonic level gauge and guided wave radar level gauge; Electrical characteristics: radio frequency admittance level gauge, capacitance level gauge, etc.
Contents of JJG 971-2019
Introduction I 1 Scope 2 Normative references 3 Terms and meteorological units 4 General 5 Metrological performance requirements 6 General technical requirements 7 Control of metrological instruments Annex A Verification record format of liquid level gauge Annex B Inside page format of verification certificate/verification result notice