2025-12-6 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/NB/T 20028.4-2010
NB/T 20028.4-2010   The Batteries Used in Nuclear Power Plants - Part 4: Recommended Practice for Maintenance, Testing and Replacement (English Version)
Standard No.: NB/T 20028.4-2010 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 26000 words Translation Price(USD):780.0 remind me the price change

Email:

Implemented on:2010-10-1 Delivery: via email in 1 business day

→ → →

,,2010-10-1,141137721838726B4BE062D777CF7
Standard No.: NB/T 20028.4-2010
English Name: The Batteries Used in Nuclear Power Plants - Part 4: Recommended Practice for Maintenance, Testing and Replacement
Chinese Name: 核电厂用蓄电池 第4部分:维护、试验和更换方法
Professional Classification: NB    Professional Standard - Energy
Source Content Issued by: National Energy Administration
Issued on: 2010-5-1
Implemented on: 2010-10-1
Status: valid
Superseding:EJ/T 525.4-1997
Target Language: English
File Format: PDF
Word Count: 26000 words
Translation Price(USD): 780.0
Delivery: via email in 1 business day
The batteries used in nuclear power plants - Part 4: Recommended practice for maintenance, testing and replacement 1 Scope This part specifies the maintenance, test schedule and test methods of stationary batteries (including lead-acid batteries and nickel-cadmium batteries, hereinafter referred to as batteries except for special reference) used in nuclear power plants, and gives time guidelines for determining when to replace batteries. This part is applicable to the maintenance, testing and replacement of stationary batteries used in nuclear power plants. This part is neither applicable to other types of batteries and their applications, nor to batteries used in some special applications (e.g. emergency lighting devices and movable equipment, etc.). This part does not include supervision and testing of any other components of the DC system (battery is a part of the DC system) or the DC system itself. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. NB/T 20028.1 The batteries used in nuclear power plants - Part 1: Recommended practice for sizing NB/T 20028.2-2010 The batteries used in nuclear power plants - Part 2: Recommended practice for installation design and installation IEC 60623:2001 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells 3 Terms and definitions For the purposes of this document, the terms and definitions established in NB/T 20028.1 and NB/T 20028.2-2010 as well as the following apply. 3.1 acceptance test a constant-current or constant-power capacity test made on a new battery to determine that it meets specifications or manufacturer’s ratings 3.2 capacity test a discharge of a battery at a constant current or constant power to a specified terminal voltage 3.3 performance test a constant current or constant power capacity test, made on a battery after it has been in service, to detect any change in the capacity 3.4 modified performance test a test, in the "as found" condition, of a battery's capacity and its ability to satisfy the battery duty cycle 3.5 service test a test, in the actual condition, of a battery's capacity to satisfy the battery duty cycle
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Safety 5 Maintenance of battery 5.1 General requirements 5.2 Inspection 5.3 Corrective actions 5.4 State of charge 6 Battery test requirements 6.1 General requirements 6.2 Acceptance inspection 6.3 Performance test 6.4 Service test 6.5 Modified performance test 7 Battery test methods 7.1 Requirements 7.2 Initial conditions 7.3 Test duration and discharge rate 7.4 Capacity test methods 7.5 Acceptance, performance and modified performance tests 7.6 Service test 7.7 Restoration 8 Battery replacement criteria 8.1 Lead-acid battery 8.2 Nickel-cadmium battery 9 Record 10 Recycling and disposal 10.1 Requirements 10.2 Recycling 10.3 Disposal Annex A (Informative) Charging status of lead-acid batteries A.1 Parameters of battery discharge/charge cycle A.2 Stabilized charge current used to determine a fully charged state A.3 Electrolyte specific gravity used to determine a fully charged condition A.4 State of charge / choosing float current Annex B (Informative) Electrolyte specific gravity of lead-acid batteries B.1 Effect of charging B.2 Effect of temperature B.3 Effect of electrolyte level B.4 Effect of water addition Annex C (Normative) Appearance inspection for the installation of lead-acid battery Annex D (Informative) Urgent corrective actions of lead-acid batteries D.1 Adding water D.2 Connection resistance D.3 Battery temperature D.4 Equalizing charge Annex E (Informative) Float voltage of lead-acid batteries E.1 Battery with low terminal voltage E.2 Battery with high terminal voltage E.3 Effect of temperature Annex F (Informative) Application selection Annex G (Informative) Corrective actions for nickel-cadmium batteries G.1 Battery with low terminal voltage G.2 Water consumption G.3 Battery pack with low terminal voltage Annex H (Informative) Determination and charging of nickel-cadmium batteries in state of charge Annex I (Informative) Test methods of IEC 60623 Annex J (Informative) Effect of prolonged float charge on capacity of nickel-cadmium battery pack Annex K (Informative) Effect of temperature rise of electrolyte in vented lead-acid batteries Annex L (Normative) Modified performance test methods and examples of lead-acid batteries L.1 Objectives L.2 Rules for modified performance tests L.3 Modified performance test L.3.1 Type 1 modified performance test L.3.2 Type 2 modified performance test L.3.3 Type 3 modified performance test Annex M (Informative) Temperature correction factors of lead-acid batteries Annex N (Informative) Calculation of lead-acid battery capacity N.1 General N.2 Comparison of time- and discharge rate-adjusted performance test methods N.3 Capacity calculation example N.3.1 Example - 15min duty cycle N.3.2 Interpretation of data from tests carried out at the maximum discharge rate N.3.3 Application of discharge rate-adjusted method for other end-of-life conditions Annex O (Informative) Comparison of capacity test methods of nickel-cadmium batteries O.1 General O.2 Comparison of time- and discharge rate-adjusted performance test methods O.3 Capacity calculation examples O.3.1 General requirements O.3.2 Example - 30min duty cycle O.3.3 Interpretation of data from tests carried out at the maximum discharge rate O.3.4 Application of discharge rate-adjusted method for other capacity calculation criteria Annex P (Informative) Typical aging characteristics and end-of-life criteria of nickel-cadmium batteries Bibliography
Code of China
Standard
NB/T 20028.4-2010  The Batteries Used in Nuclear Power Plants - Part 4: Recommended Practice for Maintenance, Testing and Replacement (English Version)
Standard No.NB/T 20028.4-2010
Statusvalid
LanguageEnglish
File FormatPDF
Word Count26000 words
Price(USD)780.0
Implemented on2010-10-1
Deliveryvia email in 1 business day
Detail of NB/T 20028.4-2010
Standard No.
NB/T 20028.4-2010
English Name
The Batteries Used in Nuclear Power Plants - Part 4: Recommended Practice for Maintenance, Testing and Replacement
Chinese Name
核电厂用蓄电池 第4部分:维护、试验和更换方法
Chinese Classification
Professional Classification
NB
ICS Classification
Issued by
National Energy Administration
Issued on
2010-5-1
Implemented on
2010-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
EJ/T 525.4-1997
Language
English
File Format
PDF
Word Count
26000 words
Price(USD)
780.0
Keywords
NB/T 20028.4-2010, NB 20028.4-2010, NBT 20028.4-2010, NB/T20028.4-2010, NB/T 20028.4, NB/T20028.4, NB20028.4-2010, NB 20028.4, NB20028.4, NBT20028.4-2010, NBT 20028.4, NBT20028.4
Introduction of NB/T 20028.4-2010
The batteries used in nuclear power plants - Part 4: Recommended practice for maintenance, testing and replacement 1 Scope This part specifies the maintenance, test schedule and test methods of stationary batteries (including lead-acid batteries and nickel-cadmium batteries, hereinafter referred to as batteries except for special reference) used in nuclear power plants, and gives time guidelines for determining when to replace batteries. This part is applicable to the maintenance, testing and replacement of stationary batteries used in nuclear power plants. This part is neither applicable to other types of batteries and their applications, nor to batteries used in some special applications (e.g. emergency lighting devices and movable equipment, etc.). This part does not include supervision and testing of any other components of the DC system (battery is a part of the DC system) or the DC system itself. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. NB/T 20028.1 The batteries used in nuclear power plants - Part 1: Recommended practice for sizing NB/T 20028.2-2010 The batteries used in nuclear power plants - Part 2: Recommended practice for installation design and installation IEC 60623:2001 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells 3 Terms and definitions For the purposes of this document, the terms and definitions established in NB/T 20028.1 and NB/T 20028.2-2010 as well as the following apply. 3.1 acceptance test a constant-current or constant-power capacity test made on a new battery to determine that it meets specifications or manufacturer’s ratings 3.2 capacity test a discharge of a battery at a constant current or constant power to a specified terminal voltage 3.3 performance test a constant current or constant power capacity test, made on a battery after it has been in service, to detect any change in the capacity 3.4 modified performance test a test, in the "as found" condition, of a battery's capacity and its ability to satisfy the battery duty cycle 3.5 service test a test, in the actual condition, of a battery's capacity to satisfy the battery duty cycle
Contents of NB/T 20028.4-2010
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Safety 5 Maintenance of battery 5.1 General requirements 5.2 Inspection 5.3 Corrective actions 5.4 State of charge 6 Battery test requirements 6.1 General requirements 6.2 Acceptance inspection 6.3 Performance test 6.4 Service test 6.5 Modified performance test 7 Battery test methods 7.1 Requirements 7.2 Initial conditions 7.3 Test duration and discharge rate 7.4 Capacity test methods 7.5 Acceptance, performance and modified performance tests 7.6 Service test 7.7 Restoration 8 Battery replacement criteria 8.1 Lead-acid battery 8.2 Nickel-cadmium battery 9 Record 10 Recycling and disposal 10.1 Requirements 10.2 Recycling 10.3 Disposal Annex A (Informative) Charging status of lead-acid batteries A.1 Parameters of battery discharge/charge cycle A.2 Stabilized charge current used to determine a fully charged state A.3 Electrolyte specific gravity used to determine a fully charged condition A.4 State of charge / choosing float current Annex B (Informative) Electrolyte specific gravity of lead-acid batteries B.1 Effect of charging B.2 Effect of temperature B.3 Effect of electrolyte level B.4 Effect of water addition Annex C (Normative) Appearance inspection for the installation of lead-acid battery Annex D (Informative) Urgent corrective actions of lead-acid batteries D.1 Adding water D.2 Connection resistance D.3 Battery temperature D.4 Equalizing charge Annex E (Informative) Float voltage of lead-acid batteries E.1 Battery with low terminal voltage E.2 Battery with high terminal voltage E.3 Effect of temperature Annex F (Informative) Application selection Annex G (Informative) Corrective actions for nickel-cadmium batteries G.1 Battery with low terminal voltage G.2 Water consumption G.3 Battery pack with low terminal voltage Annex H (Informative) Determination and charging of nickel-cadmium batteries in state of charge Annex I (Informative) Test methods of IEC 60623 Annex J (Informative) Effect of prolonged float charge on capacity of nickel-cadmium battery pack Annex K (Informative) Effect of temperature rise of electrolyte in vented lead-acid batteries Annex L (Normative) Modified performance test methods and examples of lead-acid batteries L.1 Objectives L.2 Rules for modified performance tests L.3 Modified performance test L.3.1 Type 1 modified performance test L.3.2 Type 2 modified performance test L.3.3 Type 3 modified performance test Annex M (Informative) Temperature correction factors of lead-acid batteries Annex N (Informative) Calculation of lead-acid battery capacity N.1 General N.2 Comparison of time- and discharge rate-adjusted performance test methods N.3 Capacity calculation example N.3.1 Example - 15min duty cycle N.3.2 Interpretation of data from tests carried out at the maximum discharge rate N.3.3 Application of discharge rate-adjusted method for other end-of-life conditions Annex O (Informative) Comparison of capacity test methods of nickel-cadmium batteries O.1 General O.2 Comparison of time- and discharge rate-adjusted performance test methods O.3 Capacity calculation examples O.3.1 General requirements O.3.2 Example - 30min duty cycle O.3.3 Interpretation of data from tests carried out at the maximum discharge rate O.3.4 Application of discharge rate-adjusted method for other capacity calculation criteria Annex P (Informative) Typical aging characteristics and end-of-life criteria of nickel-cadmium batteries Bibliography