Test methods for purification effect of indoor air cleaning products
1 Scope
This document specifies the test methods for the capability of indoor air cleaning products (hereinafter referred to as “cleaning products”) to remove indoor air pollutants, including test conditions and sample preparation, simulated field test methods, field tests, and presentation of results.
This document is applicable to the determination of the removal effects of various cleaning products [including active cleaning products (e.g., air sterilizers, air cleaners) and passive cleaning products (e.g., formaldehyde removal boxes, activated carbon packs, sterilization packs)] for corresponding indoor air pollutants [including chemical pollutants (particulate matter, gaseous pollutants, etc.) and biological pollutants (microorganisms, allergens, etc.)].
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies.
GB/T 11742 Standard method for hygienic examination of hydrogen sulfide in air of residential areas - Methylene blue spectrophotometric method
GB/T 14295 Air filter
GB/T 18801 Air cleaner
GB/T 18883 Standards for indoor air quality
GB 19489 Laboratories - General requirements for biosafety
HJ 604 Ambient air - Determination of total hydrocarbons, methane and nonmethane hydrocarbons - Direct injection/Gas chromatography
JJF (light industry) 102 Calibration specification for test chamber of air cleaner
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
indoor air cleaning product
appliances, components or materials that have a certain removal capacity for indoor target pollutant (3.5) using technologies such as filtration, adsorption and disinfection
3.2
active cleaning product
indoor air cleaning product (3.1) driven by an electrical device
Note: For example, air sterilizers, air cleaners, etc.
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Test conditions and sample preparation
5 Simulated field test methods
6 Field test
7 Presentation of results
Annex A (Normative) Technical requirements for test chamber
Annex B (Normative) Test method for particulate matter purification
Annex C (Normative) Test method for gaseous pollutant purification
Annex D (Normative) Test method for gaseous pollutant purification (slow release method)
Annex E (Normative) Test method for microorganism removal
Annex F (Normative) Test method for allergen removal
Annex G (Informative) Indoor air quality criteria for the field test
Annex H (Informative) Determination of ethylene
Standard
QB/T 2761-2024 Test methods for purification effect of indoor air cleaning products (English)
Standard No.
QB/T 2761-2024
Status
valid
Language
English
File Format
PDF
Word Count
16000 words
Translation Price(USD)
480.0
Implemented on
2025-1-1
Delivery
via email in 1 business day
Detail of QB/T 2761-2024
Standard No.
QB/T 2761-2024
English Name
Test methods for purification effect of indoor air cleaning products
Test methods for purification effect of indoor air cleaning products
1 Scope
This document specifies the test methods for the capability of indoor air cleaning products (hereinafter referred to as “cleaning products”) to remove indoor air pollutants, including test conditions and sample preparation, simulated field test methods, field tests, and presentation of results.
This document is applicable to the determination of the removal effects of various cleaning products [including active cleaning products (e.g., air sterilizers, air cleaners) and passive cleaning products (e.g., formaldehyde removal boxes, activated carbon packs, sterilization packs)] for corresponding indoor air pollutants [including chemical pollutants (particulate matter, gaseous pollutants, etc.) and biological pollutants (microorganisms, allergens, etc.)].
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition (including any amendments) applies.
GB/T 11742 Standard method for hygienic examination of hydrogen sulfide in air of residential areas - Methylene blue spectrophotometric method
GB/T 14295 Air filter
GB/T 18801 Air cleaner
GB/T 18883 Standards for indoor air quality
GB 19489 Laboratories - General requirements for biosafety
HJ 604 Ambient air - Determination of total hydrocarbons, methane and nonmethane hydrocarbons - Direct injection/Gas chromatography
JJF (light industry) 102 Calibration specification for test chamber of air cleaner
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
indoor air cleaning product
appliances, components or materials that have a certain removal capacity for indoor target pollutant (3.5) using technologies such as filtration, adsorption and disinfection
3.2
active cleaning product
indoor air cleaning product (3.1) driven by an electrical device
Note: For example, air sterilizers, air cleaners, etc.
Contents of QB/T 2761-2024
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Test conditions and sample preparation
5 Simulated field test methods
6 Field test
7 Presentation of results
Annex A (Normative) Technical requirements for test chamber
Annex B (Normative) Test method for particulate matter purification
Annex C (Normative) Test method for gaseous pollutant purification
Annex D (Normative) Test method for gaseous pollutant purification (slow release method)
Annex E (Normative) Test method for microorganism removal
Annex F (Normative) Test method for allergen removal
Annex G (Informative) Indoor air quality criteria for the field test
Annex H (Informative) Determination of ethylene