2025-12-13 216.73.216.3
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/QX/T 248-2014
QX/T 248-2014   Technical requirements of monitoring systems for stationary hydrogen production plant with water electrolysis (English Version)
Standard No.: QX/T 248-2014 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):170.0 remind me the price change

Email:

Implemented on:2015-3-1 Delivery: via email in 1 business day

→ → →

,,2015-3-1,C952A1C32FD2B31B1457802685676
Standard No.: QX/T 248-2014
English Name: Technical requirements of monitoring systems for stationary hydrogen production plant with water electrolysis
Chinese Name: 固定式水电解制氢设备监测系统技术要求
Professional Classification: QX    Professional Standard - Meteorology
Source Content Issued by: China Meteorological Administration
Issued on: 2014-10-24
Implemented on: 2015-3-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 170.0
Delivery: via email in 1 business day
Technical requirements of monitoring systems for stationary hydrogen production plant with water electrolysis 1 Scope This standard specifies the technical requirements and check and verification of the monitoring system for stationary hydrogen production plant with water electrolysis (hereinafter referred to as the “monitoring system”). This standard is applicable to the design, production, installation, and inspection of monitoring system. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies GB 3836.1-2010 Explosive atmospheres - Part 1: Equipment - General requirements GB/T 19774-2005 Specification of water electrolyte system for producing hydrogen 3 Technical requirements 3.1 Composition The monitoring system consists of transmitter, data acquisition and processing unit, alarm device, communication network and data processing center. See Figure 1. Figure 1 Schematic diagram for monitoring system composition 3.2 Function The monitoring system shall be able to monitor the following parameters and realize on-site and remote alarm: a) working pressure, temperature, voltage, current, separator liquid level and hydrogen purity of hydrogen generator; b) hydrogen storage pressure of the hydrogen storage tank; c) hydrogen leakage concentration in hydrogen production chamber and hydrogen storage chamber; d) mains power supply status.
Foreword i 1 Scope 2 Normative references 3 Technical requirements 3.1 Composition 3.2 Function 3.3 Transmitter 3.4 Data acquisition and processing unit 3.5 Alarm device 3.6 Communication network 3.7 Data processing center 3.8 Installation 4 Check and verification 4.1 Data consistency check 4.2 Data storage function check 4.3 Real-time alarm check 4.4 Airtightness test 4.5 Equipotential bonding check 4.6 Cable insulation check
Code of China
Standard
QX/T 248-2014  Technical requirements of monitoring systems for stationary hydrogen production plant with water electrolysis (English Version)
Standard No.QX/T 248-2014
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)170.0
Implemented on2015-3-1
Deliveryvia email in 1 business day
Detail of QX/T 248-2014
Standard No.
QX/T 248-2014
English Name
Technical requirements of monitoring systems for stationary hydrogen production plant with water electrolysis
Chinese Name
固定式水电解制氢设备监测系统技术要求
Chinese Classification
Professional Classification
QX
ICS Classification
Issued by
China Meteorological Administration
Issued on
2014-10-24
Implemented on
2015-3-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
170.0
Keywords
QX/T 248-2014, QX 248-2014, QXT 248-2014, QX/T248-2014, QX/T 248, QX/T248, QX248-2014, QX 248, QX248, QXT248-2014, QXT 248, QXT248
Introduction of QX/T 248-2014
Technical requirements of monitoring systems for stationary hydrogen production plant with water electrolysis 1 Scope This standard specifies the technical requirements and check and verification of the monitoring system for stationary hydrogen production plant with water electrolysis (hereinafter referred to as the “monitoring system”). This standard is applicable to the design, production, installation, and inspection of monitoring system. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies GB 3836.1-2010 Explosive atmospheres - Part 1: Equipment - General requirements GB/T 19774-2005 Specification of water electrolyte system for producing hydrogen 3 Technical requirements 3.1 Composition The monitoring system consists of transmitter, data acquisition and processing unit, alarm device, communication network and data processing center. See Figure 1. Figure 1 Schematic diagram for monitoring system composition 3.2 Function The monitoring system shall be able to monitor the following parameters and realize on-site and remote alarm: a) working pressure, temperature, voltage, current, separator liquid level and hydrogen purity of hydrogen generator; b) hydrogen storage pressure of the hydrogen storage tank; c) hydrogen leakage concentration in hydrogen production chamber and hydrogen storage chamber; d) mains power supply status.
Contents of QX/T 248-2014
Foreword i 1 Scope 2 Normative references 3 Technical requirements 3.1 Composition 3.2 Function 3.3 Transmitter 3.4 Data acquisition and processing unit 3.5 Alarm device 3.6 Communication network 3.7 Data processing center 3.8 Installation 4 Check and verification 4.1 Data consistency check 4.2 Data storage function check 4.3 Real-time alarm check 4.4 Airtightness test 4.5 Equipotential bonding check 4.6 Cable insulation check
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
QX/T 248-2014, QX 248-2014, QXT 248-2014, QX/T248-2014, QX/T 248, QX/T248, QX248-2014, QX 248, QX248, QXT248-2014, QXT 248, QXT248