2025-12-13 216.73.216.3
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/SH 3095-2000
SH 3095-2000   Design code for wastewater treatment in petrochemical industry (English Version)
Standard No.: SH 3095-2000 Status:abolished remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 23500 words Translation Price(USD):700.0 remind me the price change

Email:

Implemented on:2000-10-1 Delivery: via email in 1 business day

→ → →

2017-05-12 ,,2000-10-1,141137367771138CA919BE0B917AA
Standard No.: SH 3095-2000
English Name: Design code for wastewater treatment in petrochemical industry
Chinese Name: 石油化工污水处理设计规范
Chinese Classification: Z23    Analysis methods for industrial wastewater and pollutants
Professional Classification: SH    Professional Standard - Petrochemical
Source Content Issued by: the State Bureau of Petroleum and Chemical Industry
Issued on: 2000-06-30
Implemented on: 2000-10-1
Status: abolished
Abolished on:2017-05-12
Target Language: English
File Format: PDF
Word Count: 23500 words
Translation Price(USD): 700.0
Delivery: via email in 1 business day
Design code for wastewater treatment in petrochemical industry 1 General provisions 1.0.1 This code is specially formulated to implement relevant national guidelines, policies and decrees and achieve the purpose of preventing and controlling pollution, improving and protecting the environment. 1.0.2 This code is applicable to the design of constructed, extended and renovated wastewater treatment engineering in petrochemical industry. 1.0.3 The design of wastewater treatment engineering in petrochemical industry must be based on the approved feasibility study report and environmental impact report, and shall be combined with comprehensive planning, particular treatment and centralized treatment to ensure advanced technology, reasonable economy, reliable operation and environmental protection. 1.0.4 The design of wastewater treatment engineering in petrochemical industry shall meet those specified in both this code and the current relevant mandatory standards. 2 Terms 2.0.1 wastewater pretreatment treatment with regard to certain specific pollutants before discharging the wastewater into centralized wastewater treatment plant for meeting the inflow water quality of centralized wastewater treatment plant 2.0.2 wastewater particular treatment local treatment of wastewater separately without discharging the wastewater into centralized wastewater treatment plant. The wastewater after particular treatment may be reused, recycled or directly discharged 2.0.3 non-polluted wastewater wastewater that is not polluted or slightly polluted and the water temperature rises slightly and meets the discharge standard without treatment 2.0.4 polluted rainwater initial rainwater on the ground of contaminated areas that may be contaminated by materials 3 Water quality, quantity and system division 3.1 Water quality 3.1.1 The quality of the wastewater discharged from installations (units) as well as that flowing into the wastewater treatment plant shall meet the relevant requirements of SH 3099 Water quality standard of water supply and drainage in petrochemical industry and those in environmental impact report. 3.1.2 The total inflow water quality of wastewater treatment plant shall be determined by calculation according to the drainage water quality and quantity of each installation (unit). In case of lack of data, it may be determined by referring to the actual operation data of similar factories. 3.1.3 The quality of discharged water after wastewater treatment shall conform to relevant national and local standards. 3.2 Water quantity 3.2.1 The maximum allowable discharge quantity of petrochemical industry shall meet the requirements of the current national standard GB 8978 Integrated wastewater discharge standard. 3.2.2 The design wastewater quantity shall be calculated according to the wastewater quantity of each installation (unit) based on different systems. 3.2.3 The design wastewater quantity shall include production wastewater quantity, domestic wastewater quantity, polluted rainwater quantity and unforeseen wastewater quantity. Various wastewater quantities shall be determined according to the following requirements:
Foreword iv 1 General provisions 2 Terms 3 Water quality, quantity and system division 3.1 Water quality 3.2 Water quantity 3.3 Division of wastewater treatment system 4 Wastewater pretreatment and particular treatment 4.1 General requirements 4.2 Wastewater from refining industry 4.3 Wastewater from petrochemical industry 4.4 Wastewater from chemical fiber industry 4.5 Wastewater from chemical fertilizer industry 5 Wastewater treatment 5.1 Bar screen 5.2 Regulation and equalization 5.3 Neutralization 5.4 Oil separation 5.5 Air flotation 5.6 Dosage and mixing 5.7 Condensation reaction 5.8 Biomembrane process 5.9 Activated sludge process 5.10 Sedimentation 5.11 Anaerobic process 5.12 Filtration 5.13 Monitoring pool 6 Sludge treatment and sump oil recovery 6.1 Calculation of sludge quantity 6.2 Sludge transportation 6.3 Sludge thickening 6.4 Sludge dewatering 6.5 Sludge disposal 6.6 Sump oil recovery 7 Overall design of wastewater treatment 7.1 Site selection of wastewater treatment plant 7.2 Wastewater treatment process 7.3 General layout 7.4 Elevation layout 7.5 Instruments and automatic control 7.6 Laboratory analysis 7.7 Production and auxiliary buildings Explanation of wording in this code
Code of China
Standard
SH 3095-2000  Design code for wastewater treatment in petrochemical industry (English Version)
Standard No.SH 3095-2000
Statusabolished
LanguageEnglish
File FormatPDF
Word Count23500 words
Price(USD)700.0
Implemented on2000-10-1
Deliveryvia email in 1 business day
Detail of SH 3095-2000
Standard No.
SH 3095-2000
English Name
Design code for wastewater treatment in petrochemical industry
Chinese Name
石油化工污水处理设计规范
Chinese Classification
Z23
Professional Classification
SH
ICS Classification
Issued by
the State Bureau of Petroleum and Chemical Industry
Issued on
2000-06-30
Implemented on
2000-10-1
Status
abolished
Superseded by
Superseded on
Abolished on
2017-05-12
Superseding
Language
English
File Format
PDF
Word Count
23500 words
Price(USD)
700.0
Keywords
SH 3095-2000, SH/T 3095-2000, SHT 3095-2000, SH3095-2000, SH 3095, SH3095, SH/T3095-2000, SH/T 3095, SH/T3095, SHT3095-2000, SHT 3095, SHT3095
Introduction of SH 3095-2000
Design code for wastewater treatment in petrochemical industry 1 General provisions 1.0.1 This code is specially formulated to implement relevant national guidelines, policies and decrees and achieve the purpose of preventing and controlling pollution, improving and protecting the environment. 1.0.2 This code is applicable to the design of constructed, extended and renovated wastewater treatment engineering in petrochemical industry. 1.0.3 The design of wastewater treatment engineering in petrochemical industry must be based on the approved feasibility study report and environmental impact report, and shall be combined with comprehensive planning, particular treatment and centralized treatment to ensure advanced technology, reasonable economy, reliable operation and environmental protection. 1.0.4 The design of wastewater treatment engineering in petrochemical industry shall meet those specified in both this code and the current relevant mandatory standards. 2 Terms 2.0.1 wastewater pretreatment treatment with regard to certain specific pollutants before discharging the wastewater into centralized wastewater treatment plant for meeting the inflow water quality of centralized wastewater treatment plant 2.0.2 wastewater particular treatment local treatment of wastewater separately without discharging the wastewater into centralized wastewater treatment plant. The wastewater after particular treatment may be reused, recycled or directly discharged 2.0.3 non-polluted wastewater wastewater that is not polluted or slightly polluted and the water temperature rises slightly and meets the discharge standard without treatment 2.0.4 polluted rainwater initial rainwater on the ground of contaminated areas that may be contaminated by materials 3 Water quality, quantity and system division 3.1 Water quality 3.1.1 The quality of the wastewater discharged from installations (units) as well as that flowing into the wastewater treatment plant shall meet the relevant requirements of SH 3099 Water quality standard of water supply and drainage in petrochemical industry and those in environmental impact report. 3.1.2 The total inflow water quality of wastewater treatment plant shall be determined by calculation according to the drainage water quality and quantity of each installation (unit). In case of lack of data, it may be determined by referring to the actual operation data of similar factories. 3.1.3 The quality of discharged water after wastewater treatment shall conform to relevant national and local standards. 3.2 Water quantity 3.2.1 The maximum allowable discharge quantity of petrochemical industry shall meet the requirements of the current national standard GB 8978 Integrated wastewater discharge standard. 3.2.2 The design wastewater quantity shall be calculated according to the wastewater quantity of each installation (unit) based on different systems. 3.2.3 The design wastewater quantity shall include production wastewater quantity, domestic wastewater quantity, polluted rainwater quantity and unforeseen wastewater quantity. Various wastewater quantities shall be determined according to the following requirements:
Contents of SH 3095-2000
Foreword iv 1 General provisions 2 Terms 3 Water quality, quantity and system division 3.1 Water quality 3.2 Water quantity 3.3 Division of wastewater treatment system 4 Wastewater pretreatment and particular treatment 4.1 General requirements 4.2 Wastewater from refining industry 4.3 Wastewater from petrochemical industry 4.4 Wastewater from chemical fiber industry 4.5 Wastewater from chemical fertilizer industry 5 Wastewater treatment 5.1 Bar screen 5.2 Regulation and equalization 5.3 Neutralization 5.4 Oil separation 5.5 Air flotation 5.6 Dosage and mixing 5.7 Condensation reaction 5.8 Biomembrane process 5.9 Activated sludge process 5.10 Sedimentation 5.11 Anaerobic process 5.12 Filtration 5.13 Monitoring pool 6 Sludge treatment and sump oil recovery 6.1 Calculation of sludge quantity 6.2 Sludge transportation 6.3 Sludge thickening 6.4 Sludge dewatering 6.5 Sludge disposal 6.6 Sump oil recovery 7 Overall design of wastewater treatment 7.1 Site selection of wastewater treatment plant 7.2 Wastewater treatment process 7.3 General layout 7.4 Elevation layout 7.5 Instruments and automatic control 7.6 Laboratory analysis 7.7 Production and auxiliary buildings Explanation of wording in this code
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
SH 3095-2000, SH/T 3095-2000, SHT 3095-2000, SH3095-2000, SH 3095, SH3095, SH/T3095-2000, SH/T 3095, SH/T3095, SHT3095-2000, SHT 3095, SHT3095