2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/SH/T 3164-2012
SH/T 3164-2012   Specification for design of instrument system lightning surge protection in petrochemical engineering (English Version)
Standard No.: SH/T 3164-2012 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):300.0 remind me the price change

Email:

Implemented on:2013-3-1 Delivery: via email in 1 business day

→ → →

,2022-2-1,2013-3-1,14113782000137580044382D64BEC
Standard No.: SH/T 3164-2012
English Name: Specification for design of instrument system lightning surge protection in petrochemical engineering
Chinese Name: 石油化工仪表系统防雷工程设计规范
Professional Classification: SH    Professional Standard - Petrochemical
ICS Classification: 91.120.40 91.120.40    Lightning protection 91.120.40
Source Content Issued by: MIIT
Issued on: 2012-11-7
Implemented on: 2013-3-1
Status: superseded
Superseded by:SH/T 3164-2021 Design specification for instrument system lightning surge protection in petrochemical industry
Superseded on:2022-2-1
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 300.0
Delivery: via email in 1 business day
This Specification specifies the design contents for the instrument system lightning protection engineering, including design method, lightning protection level, lightning protection for field instrumentation in explosive environment, equipotential bonding and earthing system, selection of surge protective device, laying and shielding of cables, and lightning protection for field-bus system. This Specification is applicable to the lightning protection engineering design for the instrument and automatic control system in the flammable and explosive environment or non-flammable and non-explosive environment of constructed, renovated and extended projects in petrochemical industry. This Specification is not applicable to the lightning protection for the industrial television monitoring system and fire alarm system in the petrochemical enterprises.
Foreword i 1 Scope 2 Terms and Definitions 2.1 Integrated Lightning Protection Engineering 2.2 Lightning Electromagnetic Induction 2.3 Equipotential Bonding System 2.4 Surge Protective Device 3 Lightning Protection Level 3.1 Lightning Active Area 3.2 Lightning Protection Level 3.3 Important Grade Class of System 4 Lightning Protection Design for Control Room Structure 4.1 Direct Lightning Flash Protection Design for Control Room Structure 4.2 Correlative Design in Control Room 5 Lightning Protection Engineering Method for Instrumentation System 5.1 Design Principle 5.2 Integrated Lightning Protection 5.3 Lightning Protection Basic Method for Instrumentation System 5.4 Equipotential Bonding and Earthing 6 Design for Equipotential Bonding and Earthing System 6.1 Structure of Earthing System 6.2 Specification for Design of Earthing System 6.3 Design of Equipotential Bonding System 6.4 Earthing Mode for Instrumentation Power Distributing 6.5 Bonding for Surge Protective Device in Control Room 6.6 Bonding Conductor and Wire 6.7 Earthing Sign 7 Lightning Protection for Instrumentation System in Control Room 7.1 Shielding for Instrumentation System in Control Room 7.2 Cabinet Earthing 7.3 Entry Method of Cables to Control Room 7.4 Surge Protective Device in Control Room 7.5 Bounding of Non Intrinsic Safety System 7.6 Bounding of Intrinsic Safety System 7.7 Wires in Bonding and Earthing System 8 Surge Protective Device Setup 8.1 General 8.2 Surge Protective Device Usage Principle 8.3 Type of Surge Protective Devices 8.4 Parameters of Surge Protective Device of Signal Loop 8.5 Surge Protective Device for Field Instrumentation 8.6 Surge Protection in AC Power Line 8.7 Surge Protective Device for Communication Device 9 Lightning Protection for Field Instrumentation 9.1 Protection for Field Instrumentation 9.2 Field Instrumentation Earthing 9.3 Surge Protective Device Mode 10 Lightning Protection for Intrinsic Safety System 10.1 Surge Protective Device for Intrinsic Safety System 10.2 Surge Protective Device Setup in Intrinsic Safety System 10.3 Bounding In Intrinsic Safety System 11 Laying and Shielding of Cables 11.1 Laying of Cable 11.2 Shielding of Cables 11.3 Earthing of Cable Shielding 11.4 Spare Cable and Spare Core of Cable 11.5 Signal Cable Form 11.6 Other Notes for Laying of Cables 12 Lightning Protection for Field-Bus System 12.1 Lightning Protection for Field-Bus System 12.2 Protection for Field-Bus System in Explosive Area 12.3 Surge Protective Device for Field-Bus System 12.4 Signal Cable for Field-Bus System Bibliography Explanation of Wording in This Specification
SH/T 3164-2012 is referred in:
* HG/T 20573-2012 Code for Distributed Control System Engineering Design
* HG/T 20573-2012 Code for Distributed Control System Engineering Design
*SH/T 3092-2013 Code for the design of distributed control system for petrochemical industry
*SH/T 3082-2019 Design code for instrument power supply in petrochemical industry
*GB 51156-2015 Code for design of liquefied natural gas receiving terminal
Code of China
Standard
SH/T 3164-2012  Specification for design of instrument system lightning surge protection in petrochemical engineering (English Version)
Standard No.SH/T 3164-2012
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)300.0
Implemented on2013-3-1
Deliveryvia email in 1 business day
Detail of SH/T 3164-2012
Standard No.
SH/T 3164-2012
English Name
Specification for design of instrument system lightning surge protection in petrochemical engineering
Chinese Name
石油化工仪表系统防雷工程设计规范
Chinese Classification
Professional Classification
SH
ICS Classification
Issued by
MIIT
Issued on
2012-11-7
Implemented on
2013-3-1
Status
superseded
Superseded by
SH/T 3164-2021 Design specification for instrument system lightning surge protection in petrochemical industry
Superseded on
2022-2-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
300.0
Keywords
SH/T 3164-2012, SH 3164-2012, SHT 3164-2012, SH/T3164-2012, SH/T 3164, SH/T3164, SH3164-2012, SH 3164, SH3164, SHT3164-2012, SHT 3164, SHT3164
Introduction of SH/T 3164-2012
This Specification specifies the design contents for the instrument system lightning protection engineering, including design method, lightning protection level, lightning protection for field instrumentation in explosive environment, equipotential bonding and earthing system, selection of surge protective device, laying and shielding of cables, and lightning protection for field-bus system. This Specification is applicable to the lightning protection engineering design for the instrument and automatic control system in the flammable and explosive environment or non-flammable and non-explosive environment of constructed, renovated and extended projects in petrochemical industry. This Specification is not applicable to the lightning protection for the industrial television monitoring system and fire alarm system in the petrochemical enterprises.
Contents of SH/T 3164-2012
Foreword i 1 Scope 2 Terms and Definitions 2.1 Integrated Lightning Protection Engineering 2.2 Lightning Electromagnetic Induction 2.3 Equipotential Bonding System 2.4 Surge Protective Device 3 Lightning Protection Level 3.1 Lightning Active Area 3.2 Lightning Protection Level 3.3 Important Grade Class of System 4 Lightning Protection Design for Control Room Structure 4.1 Direct Lightning Flash Protection Design for Control Room Structure 4.2 Correlative Design in Control Room 5 Lightning Protection Engineering Method for Instrumentation System 5.1 Design Principle 5.2 Integrated Lightning Protection 5.3 Lightning Protection Basic Method for Instrumentation System 5.4 Equipotential Bonding and Earthing 6 Design for Equipotential Bonding and Earthing System 6.1 Structure of Earthing System 6.2 Specification for Design of Earthing System 6.3 Design of Equipotential Bonding System 6.4 Earthing Mode for Instrumentation Power Distributing 6.5 Bonding for Surge Protective Device in Control Room 6.6 Bonding Conductor and Wire 6.7 Earthing Sign 7 Lightning Protection for Instrumentation System in Control Room 7.1 Shielding for Instrumentation System in Control Room 7.2 Cabinet Earthing 7.3 Entry Method of Cables to Control Room 7.4 Surge Protective Device in Control Room 7.5 Bounding of Non Intrinsic Safety System 7.6 Bounding of Intrinsic Safety System 7.7 Wires in Bonding and Earthing System 8 Surge Protective Device Setup 8.1 General 8.2 Surge Protective Device Usage Principle 8.3 Type of Surge Protective Devices 8.4 Parameters of Surge Protective Device of Signal Loop 8.5 Surge Protective Device for Field Instrumentation 8.6 Surge Protection in AC Power Line 8.7 Surge Protective Device for Communication Device 9 Lightning Protection for Field Instrumentation 9.1 Protection for Field Instrumentation 9.2 Field Instrumentation Earthing 9.3 Surge Protective Device Mode 10 Lightning Protection for Intrinsic Safety System 10.1 Surge Protective Device for Intrinsic Safety System 10.2 Surge Protective Device Setup in Intrinsic Safety System 10.3 Bounding In Intrinsic Safety System 11 Laying and Shielding of Cables 11.1 Laying of Cable 11.2 Shielding of Cables 11.3 Earthing of Cable Shielding 11.4 Spare Cable and Spare Core of Cable 11.5 Signal Cable Form 11.6 Other Notes for Laying of Cables 12 Lightning Protection for Field-Bus System 12.1 Lightning Protection for Field-Bus System 12.2 Protection for Field-Bus System in Explosive Area 12.3 Surge Protective Device for Field-Bus System 12.4 Signal Cable for Field-Bus System Bibliography Explanation of Wording in This Specification
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
SH/T 3164-2012, SH 3164-2012, SHT 3164-2012, SH/T3164-2012, SH/T 3164, SH/T3164, SH3164-2012, SH 3164, SH3164, SHT3164-2012, SHT 3164, SHT3164