Determination methods for all solid-state battery
1 Scope
This document specifies the determination requirements for all solid-state battery and describes the test method for liquid content.
This document is applicable to the determination of all solid-state battery and the testing of liquid content inside the battery.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
solid-state electrolyte
solid material containing mobile ions and possessing ionic conductivity
3.2
all solid-state battery
battery in which ions are transferred between the positive and negative electrodes by the solid-state electrolyte (3.1)
4 Symbols
For the purposes of this document, the following symbols apply.
I1: 1h rate discharge current, in amperes (A), numerically equal to the rated capacity value.
I3: 3h rate discharge current, in amperes (A), numerically equal to one third of the rated capacity value.
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Determination requirements for all solid-state battery
6 Test method for liquid content
Standard
T/CSAE 434-2025 Determination methods for all solid-state battery (English Version)
Determination methods for all solid-state battery
1 Scope
This document specifies the determination requirements for all solid-state battery and describes the test method for liquid content.
This document is applicable to the determination of all solid-state battery and the testing of liquid content inside the battery.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
solid-state electrolyte
solid material containing mobile ions and possessing ionic conductivity
3.2
all solid-state battery
battery in which ions are transferred between the positive and negative electrodes by the solid-state electrolyte (3.1)
4 Symbols
For the purposes of this document, the following symbols apply.
I1: 1h rate discharge current, in amperes (A), numerically equal to the rated capacity value.
I3: 3h rate discharge current, in amperes (A), numerically equal to one third of the rated capacity value.
Contents of T/CSAE 434-2025
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Determination requirements for all solid-state battery
6 Test method for liquid content