2025-12-15 216.73.216.3
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YD/T 5024-2005
YD/T 5024-2005   Design Specification for SDH Local Network Optical Fiber Cable Transmission Project (English Version)
Standard No.: YD/T 5024-2005 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:2006-6-1 Delivery: via email in 1 business day

→ → →

,2014-7-1,2006-6-1,14113746953234FB5840703E65C81
Standard No.: YD/T 5024-2005
English Name: Design Specification for SDH Local Network Optical Fiber Cable Transmission Project
Chinese Name: SDH本地网光缆传输工程设计规范
Chinese Classification: P76    Communication engineering
Professional Classification: YD    Professional Standard - Telecommunication
ICS Classification: 33 33    Telecommunications. Audio and video engineering 33
Source Content Issued by: Ministry of Information Industry
Issued on: 2006-2-28
Implemented on: 2006-6-1
Status: superseded
Superseded by:YD 5095-2014 Design Specification for Synchronous Digital Hierarchy (SDH) Optical Fiber Transmission System Project
Superseded on:2014-7-1
Superseding:YD 5024-1996 SDH Optical Fiber Cable Trunk Transmission Project Designing Standard for Local Telephone Network
YD 5075-1998 Digital Cross-connect Equipment Engineering Designing Standard for Local Telephone Network
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This specification is applicable to the design of reconstructed or extended local transmission network SDH optical fiber cable transmission project, and the private communication network synchronous digital transmission equipment project may be implemented with reference to this specification. 1.0.2 The project design must comply with the principles and policies of the state or the relevant authorities and follow the scientificity, rationality and fairness of the design. 1.0.3 The design shall be of practicality, advanced technology and economic rationality. Multi-scheme technical and economic comparison shall be carried out to reduce the construction costs and improve the social benefits and economic benefits. 1.0.4 The design shall be appropriate to the integral development planning of the local communication, based on the short-term requirements, and in consideration of the long-term development, for the convenience of dilatation. 1.0.5 The telecommunication equipments adopted in project design shall have the telecommunication equipment network access licenses issued by the Ministry of Information Industry. The equipments without telecommunication equipment network access licenses issued by the Ministry of Information Industry shall not be used in the project. The major equipment used in the public telecommunication network of the areas with the seismic fortification intensity of 7 or above in our country, shall have telecommunication equipment seismic performance testing quality certificates issued by the Ministry of Information Industry, and the telecommunication equipments without telecommunication equipment seismic performance testing quality certificates issued by the Ministry of Information Industry shall not be used in the project. 1.0.6 Under the premise of ensuring the communication quality, the convenience of the construction and maintenance, the tidiness and esthetic appearance of the machine room as well as the communication security under the natural disaster and emergencies shall be taken into consideration in the project design. 1.0.7 The parts not involved in this specification may refer to the design specifications of the current relevant projects. 1.0.8 When this specification conflicts with the national requirements, the national requirements shall be applied. Where it is difficult to implement some provision of this specification, sufficient reasons shall be stated in the design and shall be examined and approved by competent department. 2 Terms and Symbols English abbreviation English full name Chinese name ADM Add and Drop Multiplexer 分插复用器 BA Booster Amplifier 功率放大器,简称功放 BBER Background Block Error Ratio 背景误块比,背景差错块比 BER Bit Error Ratio 误码率,误比特率,比特差错比 BITS Building Integrated Timing Supply 大楼综合定时供给系统 BISPO Bring Into Service Performance Objective 投入业务性能指标 CMI Coded Mark Inversion 编码传号反转码 DDF Digital Distribution Frame 数字分配架 DXC Digital cross connect equipment 数字交叉连接设备 EMS Element Management System 网元级管理系统 ES Errored Second 误码秒,误块秒 ESR Errored Second Ratio 误码秒比,误块秒比 HRDS Hypothetical Reference Digital Section 假设参考数字段 HRP Hypothetical Reference Path 假设参考通道 LA Line Amplifier 线路放大器 LAN Local Area Network 局域网 LCF Local craft terminal 本地维护终端 MLM Multi-longitudinal Mode Laser 多纵模激光器 MPI Main Path Interface 主通道接口 NE Network Element 网元 NMS Network Management System 网络级管理系统 OA Optical Amplifier 光放大器 ODF Optical Distribution Frame 光纤分配架 OTU Optical Transponder Unit 光转换器单元 PA Pre-amplifier 前置放大器,简称前放 PC Plane Connection 平面连接 PDC Passive Dispersion Compensator 无源色散补偿器 PDH Plesiochronous Digital Hierarchy 准同步数字系列 PMD Polarization Mode Dispersion 极化模色散 PEG Regenerator 再生器 RMS Radical Mean Square 均方根 Rx Receiver 接收机 SDH Synchronous Digital Hierarchy 同步数字系列 SES Severely Errored Second 严重误码秒,严重误块秒 SESR Severely Errored Second Ratio 严重误码秒比,严重误块秒比 SLM Single-longitudinal Mode Laser 单纵模激光器 SMS Sub Network Management System 子网级管理系统 SNCP Subnetwork Connection Protection 子网连接保护 SPM Self-phrase Modulation 自相位调制 STM Synchronous Transport Module 同步传送模块 TM Termination Multiplexer 终端复用器 Tx Transmitter 发送机 VC Virtual Container 虚容器 WDM Wavelength Division Multiplexing 波分复用 3 System Rate and Multiplex Structure 3.0.1 Bit ratio grade of SDH signal at the network node shall be in accordance with those specified in Table 3.0.1. Table 3.0.1 Bit ratio grade of SDH signal at the network node SDH Bit ratio (kbit/s) STM-1 155520 STM-4 622080 STM-16 2488320 STM-64 9953280 3.0.2 The basic multiplex structure shall meet the requirements of Figure 3.0.2. Note: 44 736 kbit/s interface is mainly used for transmitting IP service and image service Figure 3.0.2 Basic multiplex mapping structure 4 Network Structure 4.0.1 Local SDH transmission network should be constructed by the layered structure including core layer, convergence layer and access layer and shall meet the requirements of Figure 4.0.1. Figure 4.0.1 Schematic diagram of local transmission network layered structure 4.0.2 The network layer classification shall be determined according to the size of local transmission network. The local network of small size may be properly reduced with the transmission network layers. 4.0.3 The core layer network size should not be oversized; the convergence layer should be constructed by region and the node quantity in different convergence regions should be relative equilibrium; the access layer network should be constructed according to the service attribute. 4.0.4 The transmission nodes may be divided into the core node, convergence node and access node. The transmission nodes shall be set according to the general development plan of telecommunication network, in consideration of various factors. 5 Network Organization 5.1 Determination of Size and Capacity 5.1.1 The transmission rate and system capacity of the transmission system shall be selected and configured according to the requirements of project satisfaction period, service volume and network redundancy in the satisfaction period. 5.1.2 The requirements of miscellaneous services to the transmission network and the requirements of network redundancy shall be taken into comprehensive consideration in the service prediction. 5.1.3 Configuration of transmission system shall meet the following requirements: 1. The security requirements of the bearer services shall be taken into consideration in the system configuration. 2. When more than two low-rate transmission systems are configured, the possibility of selecting high-rate transmission systems shall be demonstrated. 3. The system mode and system rate shall be taken into comprehensive consideration in combination with the optical fiber resources and optical fiber technology conditions. 4. The then commercial level of the equipment shall be taken into consideration for the determination of transmission system mode and capacity. 5.2 SDH Network Organization Mode
Contents 1 General Provisions 2 Terms and Symbols 3 System Rate and Multiplex Structure 4 Network Structure 5 Network Organization 5.1 Determination of Size and Capacity 5.2 SDH Network Organization Mode 5.3 Network Security and Protection 6 Transmission System Design 6.1 Interface Design 6.2 Repeater Section Design 6.3 Optical Fiber Type and Operating Wavelength Selection 7 Channel Organization and Path Arrangement 8 Auxiliary System 8.1 Network Management System 8.2 Network Synchronization Design 8.3 Official Business Contact System 9 Interconnection and Intercommunication 9.1 Intercommunication between PDH and SDH Systems 9.2 Intercommunication between the Equipment Made by Different Manufacturers 10 Equipment Selection and Configuration 10.1 Equipment Selection 10.2 Equipment Configuration 11 Equipment Installation Design 11.1 Machine Room Plane Layout and Equipment Arrangement 11.2 Equipment Installation 11.3 Wiring Requirements and Wire Cable Selection 11.4 Power Supply System 11.5 Environmental Conditions of Machine Room 12 Transmission System Design Index 12.1 Hypothetical Reference Path and Digital Section 12.2 Error Index 12.3 Jitter and Wander 12.4 Usability Objective 13 Maintenance Tools and Instrument Configuration
Code of China
Standard
YD/T 5024-2005  Design Specification for SDH Local Network Optical Fiber Cable Transmission Project (English Version)
Standard No.YD/T 5024-2005
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on2006-6-1
Deliveryvia email in 1 business day
Detail of YD/T 5024-2005
Standard No.
YD/T 5024-2005
English Name
Design Specification for SDH Local Network Optical Fiber Cable Transmission Project
Chinese Name
SDH本地网光缆传输工程设计规范
Chinese Classification
P76
Professional Classification
YD
ICS Classification
Issued by
Ministry of Information Industry
Issued on
2006-2-28
Implemented on
2006-6-1
Status
superseded
Superseded by
YD 5095-2014 Design Specification for Synchronous Digital Hierarchy (SDH) Optical Fiber Transmission System Project
Superseded on
2014-7-1
Abolished on
Superseding
YD 5024-1996 SDH Optical Fiber Cable Trunk Transmission Project Designing Standard for Local Telephone Network
YD 5075-1998 Digital Cross-connect Equipment Engineering Designing Standard for Local Telephone Network
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
YD/T 5024-2005, YD 5024-2005, YDT 5024-2005, YD/T5024-2005, YD/T 5024, YD/T5024, YD5024-2005, YD 5024, YD5024, YDT5024-2005, YDT 5024, YDT5024
Introduction of YD/T 5024-2005
1 General Provisions 1.0.1 This specification is applicable to the design of reconstructed or extended local transmission network SDH optical fiber cable transmission project, and the private communication network synchronous digital transmission equipment project may be implemented with reference to this specification. 1.0.2 The project design must comply with the principles and policies of the state or the relevant authorities and follow the scientificity, rationality and fairness of the design. 1.0.3 The design shall be of practicality, advanced technology and economic rationality. Multi-scheme technical and economic comparison shall be carried out to reduce the construction costs and improve the social benefits and economic benefits. 1.0.4 The design shall be appropriate to the integral development planning of the local communication, based on the short-term requirements, and in consideration of the long-term development, for the convenience of dilatation. 1.0.5 The telecommunication equipments adopted in project design shall have the telecommunication equipment network access licenses issued by the Ministry of Information Industry. The equipments without telecommunication equipment network access licenses issued by the Ministry of Information Industry shall not be used in the project. The major equipment used in the public telecommunication network of the areas with the seismic fortification intensity of 7 or above in our country, shall have telecommunication equipment seismic performance testing quality certificates issued by the Ministry of Information Industry, and the telecommunication equipments without telecommunication equipment seismic performance testing quality certificates issued by the Ministry of Information Industry shall not be used in the project. 1.0.6 Under the premise of ensuring the communication quality, the convenience of the construction and maintenance, the tidiness and esthetic appearance of the machine room as well as the communication security under the natural disaster and emergencies shall be taken into consideration in the project design. 1.0.7 The parts not involved in this specification may refer to the design specifications of the current relevant projects. 1.0.8 When this specification conflicts with the national requirements, the national requirements shall be applied. Where it is difficult to implement some provision of this specification, sufficient reasons shall be stated in the design and shall be examined and approved by competent department. 2 Terms and Symbols English abbreviation English full name Chinese name ADM Add and Drop Multiplexer 分插复用器 BA Booster Amplifier 功率放大器,简称功放 BBER Background Block Error Ratio 背景误块比,背景差错块比 BER Bit Error Ratio 误码率,误比特率,比特差错比 BITS Building Integrated Timing Supply 大楼综合定时供给系统 BISPO Bring Into Service Performance Objective 投入业务性能指标 CMI Coded Mark Inversion 编码传号反转码 DDF Digital Distribution Frame 数字分配架 DXC Digital cross connect equipment 数字交叉连接设备 EMS Element Management System 网元级管理系统 ES Errored Second 误码秒,误块秒 ESR Errored Second Ratio 误码秒比,误块秒比 HRDS Hypothetical Reference Digital Section 假设参考数字段 HRP Hypothetical Reference Path 假设参考通道 LA Line Amplifier 线路放大器 LAN Local Area Network 局域网 LCF Local craft terminal 本地维护终端 MLM Multi-longitudinal Mode Laser 多纵模激光器 MPI Main Path Interface 主通道接口 NE Network Element 网元 NMS Network Management System 网络级管理系统 OA Optical Amplifier 光放大器 ODF Optical Distribution Frame 光纤分配架 OTU Optical Transponder Unit 光转换器单元 PA Pre-amplifier 前置放大器,简称前放 PC Plane Connection 平面连接 PDC Passive Dispersion Compensator 无源色散补偿器 PDH Plesiochronous Digital Hierarchy 准同步数字系列 PMD Polarization Mode Dispersion 极化模色散 PEG Regenerator 再生器 RMS Radical Mean Square 均方根 Rx Receiver 接收机 SDH Synchronous Digital Hierarchy 同步数字系列 SES Severely Errored Second 严重误码秒,严重误块秒 SESR Severely Errored Second Ratio 严重误码秒比,严重误块秒比 SLM Single-longitudinal Mode Laser 单纵模激光器 SMS Sub Network Management System 子网级管理系统 SNCP Subnetwork Connection Protection 子网连接保护 SPM Self-phrase Modulation 自相位调制 STM Synchronous Transport Module 同步传送模块 TM Termination Multiplexer 终端复用器 Tx Transmitter 发送机 VC Virtual Container 虚容器 WDM Wavelength Division Multiplexing 波分复用 3 System Rate and Multiplex Structure 3.0.1 Bit ratio grade of SDH signal at the network node shall be in accordance with those specified in Table 3.0.1. Table 3.0.1 Bit ratio grade of SDH signal at the network node SDH Bit ratio (kbit/s) STM-1 155520 STM-4 622080 STM-16 2488320 STM-64 9953280 3.0.2 The basic multiplex structure shall meet the requirements of Figure 3.0.2. Note: 44 736 kbit/s interface is mainly used for transmitting IP service and image service Figure 3.0.2 Basic multiplex mapping structure 4 Network Structure 4.0.1 Local SDH transmission network should be constructed by the layered structure including core layer, convergence layer and access layer and shall meet the requirements of Figure 4.0.1. Figure 4.0.1 Schematic diagram of local transmission network layered structure 4.0.2 The network layer classification shall be determined according to the size of local transmission network. The local network of small size may be properly reduced with the transmission network layers. 4.0.3 The core layer network size should not be oversized; the convergence layer should be constructed by region and the node quantity in different convergence regions should be relative equilibrium; the access layer network should be constructed according to the service attribute. 4.0.4 The transmission nodes may be divided into the core node, convergence node and access node. The transmission nodes shall be set according to the general development plan of telecommunication network, in consideration of various factors. 5 Network Organization 5.1 Determination of Size and Capacity 5.1.1 The transmission rate and system capacity of the transmission system shall be selected and configured according to the requirements of project satisfaction period, service volume and network redundancy in the satisfaction period. 5.1.2 The requirements of miscellaneous services to the transmission network and the requirements of network redundancy shall be taken into comprehensive consideration in the service prediction. 5.1.3 Configuration of transmission system shall meet the following requirements: 1. The security requirements of the bearer services shall be taken into consideration in the system configuration. 2. When more than two low-rate transmission systems are configured, the possibility of selecting high-rate transmission systems shall be demonstrated. 3. The system mode and system rate shall be taken into comprehensive consideration in combination with the optical fiber resources and optical fiber technology conditions. 4. The then commercial level of the equipment shall be taken into consideration for the determination of transmission system mode and capacity. 5.2 SDH Network Organization Mode
Contents of YD/T 5024-2005
Contents 1 General Provisions 2 Terms and Symbols 3 System Rate and Multiplex Structure 4 Network Structure 5 Network Organization 5.1 Determination of Size and Capacity 5.2 SDH Network Organization Mode 5.3 Network Security and Protection 6 Transmission System Design 6.1 Interface Design 6.2 Repeater Section Design 6.3 Optical Fiber Type and Operating Wavelength Selection 7 Channel Organization and Path Arrangement 8 Auxiliary System 8.1 Network Management System 8.2 Network Synchronization Design 8.3 Official Business Contact System 9 Interconnection and Intercommunication 9.1 Intercommunication between PDH and SDH Systems 9.2 Intercommunication between the Equipment Made by Different Manufacturers 10 Equipment Selection and Configuration 10.1 Equipment Selection 10.2 Equipment Configuration 11 Equipment Installation Design 11.1 Machine Room Plane Layout and Equipment Arrangement 11.2 Equipment Installation 11.3 Wiring Requirements and Wire Cable Selection 11.4 Power Supply System 11.5 Environmental Conditions of Machine Room 12 Transmission System Design Index 12.1 Hypothetical Reference Path and Digital Section 12.2 Error Index 12.3 Jitter and Wander 12.4 Usability Objective 13 Maintenance Tools and Instrument Configuration
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YD/T 5024-2005, YD 5024-2005, YDT 5024-2005, YD/T5024-2005, YD/T 5024, YD/T5024, YD5024-2005, YD 5024, YD5024, YDT5024-2005, YDT 5024, YDT5024