2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YD/T 751-1995
YD/T 751-1995   Test Method for Networking of Digital Office Telephone Exchange Equipment in Public Telephone Network (English Version)
Standard No.: YD/T 751-1995 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 40000 words Translation Price(USD):400.0 remind me the price change

Email:

Implemented on:1995-11-1 Delivery: via email in 1 business day

→ → →

,,1995-11-1,141137308984205CA9A76B9D88747
Standard No.: YD/T 751-1995
English Name: Test Method for Networking of Digital Office Telephone Exchange Equipment in Public Telephone Network
Chinese Name: 公用电话网局用数字电话交换设备进网检测方法
Chinese Classification: M15    Communication network performance index and testing
Professional Classification: YD    Professional Standard - Telecommunication
Source Content Issued by: Ministry of Posts and Telecommunications
Issued on: 1995-06-02
Implemented on: 1995-11-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 40000 words
Translation Price(USD): 400.0
Delivery: via email in 1 business day
1 Subject Contents and Application Scope 1.1 Subject content This standard specifies public testing conditions, testing instruments and equipment requirements, testing environment and sampling measures, various technical index and function testing method, subscriber signalling, interoffice signaling and synchronization testing method with regards to the digital office telephone switching equipment in public telephone network. Moreover, it specifies treatment and evaluation principle of original testing data. 1.2 Application scope This standard is applicable to network access testing and on-line quality supervision inspection of switching equipment for digital computerized telephone terminal office, tandem office, tollcall-local call office, tollcall-local call-rural call office, toll office and international export office as well as production and authentication testing of digital computerized telephone switching equipment. 2 Normative References GB 3376 "Inband Pulsing Single Frequency line Signalling System for Telephone Automatic Switching Network" GB 3377 "Multi Frequency Register Signalling System for Telephone Automatic Switching Network" GB 3378 "Subscriber Line Signalling System for Telephone Automatic Switching Network" GB 3379 "Interoffice Direct Signalling System for Telephone Automatic Switching Network" GB 3380 "Ringing and Tone for Telephone Automatic Switching Network" GB 3971.2 "Interoffice Junction Digital Line Signalling System for Telephone Automatic Switching Network" GB/T 3971.3 "The Test Methods for the Technical Specifications of Multi-frequency Register Signaling for Telephone Automatic Switching Network" GB/T 5442 "The Test Methods for the Technical Specifications of Inband Pulsing Single Frequency Line Signalling System for Automatic Telephone Switching Network" GB/T 5444 "The Test Methods for the Technical Specifications of Subscriber Line Signalling for Automatic Telephone Switching Network" GB 6879 "Technical Requirements of the 30 Channels Pulse Code Modulation Multiplex Equipment at 2048 kbit/s" GB 12048 "Requirements for Clock and Synchronization Equipment Used in the Digital Network" GF 002-9002.1 "General Technical Specification for Telephone Switching Equipment of Ministry of Posts and Telecommunications" "The Technical System for Telephone Automatic Switching Network (Trail)" "Technical System of Digital and Analog Hybrid Network in Large- and Middle-sized Cities (Interim Provisions)" Red Book of CCITT-related suggestion Q.501-507 Q.511-517 Blue Book of CCITT-related suggestion Q.500 Q.511-513 Q.521-522 Q.541-544 Q.551-554 3 Public Testing Conditions 3.1 The equipment and apparatus like code pattern converter, digital echo suppressor, canceller, digital speech interpolation devices and full-zero suppressor shall not be connected in the connecting circuit under the testing. 3.2 Half connection testing method and index are adopted for the transmission index in principle. If the half connection testing conditions are not available, the full-connection testing method may be adopted.
1 Subject Contents and Application Scope 2 Normative References 3 Public Testing Conditions 4 Requirements for Testing Instruments and Equipment 5 Random Inspection Method and Original Testing Data Treatment Principle 6 Testing of Electrical Performance of Interfaces 7 Testing of Transmission Characteristics Index 8 Transmission Characteristics Testing and Interface Parameter between Digital Trunk Interfaces 9 Subscriber Signaling and Subscriber Line Condition 10 Interoffice Signaling System Test 11 Signal Tone and Ringing Current 12 Synchronous Performance Test 13 Basic Function Testing Additional Information:
Referred in YD/T 751-1995:
* GB 3376-1982 Inband pulsing single frequency line signalling system for telephone automatic switching network
* GB 3377-1982 Multi frequency register signalling system for telephone antomatic switching network
* GB 3378-1982 Subscriber line signalling system for telephone automatic switching network
* GB 3379-
* GB 3380-1982 Ringing and tone for telephone automatic switching network
* GB 3971.2-1983 Interoffice junction digital line signalling system for telephone automatic switching network
* GB/T 3971.3-1983 The test methods for the technical specifications of multi-frequency register signaling for telephone automatic switching network
* GB/T 5442-1985 The test methods for the technical specifications of inband pulsing single frequency line signalling system for automatic telephone switching network
* GB/T 5444-1985 The test methods for the technical specifications of subscriber line signalling for automatic telephone switching network
* GB 6879-1986 GB 6880-1986
* GB 12048-1989 Requirements for clock and synchronization equipment used in the digital network
* GF 002-9002.1
YD/T 751-1995 is referred in:
* YD/T 954-1998 Technical Requirements and Test Method of Digital Stored Program C
* YD/T 954-1998 Technical Requirements and Test Method of Digital Stored Program C
Code of China
Standard
YD/T 751-1995  Test Method for Networking of Digital Office Telephone Exchange Equipment in Public Telephone Network (English Version)
Standard No.YD/T 751-1995
Statusvalid
LanguageEnglish
File FormatPDF
Word Count40000 words
Price(USD)400.0
Implemented on1995-11-1
Deliveryvia email in 1 business day
Detail of YD/T 751-1995
Standard No.
YD/T 751-1995
English Name
Test Method for Networking of Digital Office Telephone Exchange Equipment in Public Telephone Network
Chinese Name
公用电话网局用数字电话交换设备进网检测方法
Chinese Classification
M15
Professional Classification
YD
ICS Classification
Issued by
Ministry of Posts and Telecommunications
Issued on
1995-06-02
Implemented on
1995-11-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
40000 words
Price(USD)
400.0
Keywords
YD/T 751-1995, YD 751-1995, YDT 751-1995, YD/T751-1995, YD/T 751, YD/T751, YD751-1995, YD 751, YD751, YDT751-1995, YDT 751, YDT751
Introduction of YD/T 751-1995
1 Subject Contents and Application Scope 1.1 Subject content This standard specifies public testing conditions, testing instruments and equipment requirements, testing environment and sampling measures, various technical index and function testing method, subscriber signalling, interoffice signaling and synchronization testing method with regards to the digital office telephone switching equipment in public telephone network. Moreover, it specifies treatment and evaluation principle of original testing data. 1.2 Application scope This standard is applicable to network access testing and on-line quality supervision inspection of switching equipment for digital computerized telephone terminal office, tandem office, tollcall-local call office, tollcall-local call-rural call office, toll office and international export office as well as production and authentication testing of digital computerized telephone switching equipment. 2 Normative References GB 3376 "Inband Pulsing Single Frequency line Signalling System for Telephone Automatic Switching Network" GB 3377 "Multi Frequency Register Signalling System for Telephone Automatic Switching Network" GB 3378 "Subscriber Line Signalling System for Telephone Automatic Switching Network" GB 3379 "Interoffice Direct Signalling System for Telephone Automatic Switching Network" GB 3380 "Ringing and Tone for Telephone Automatic Switching Network" GB 3971.2 "Interoffice Junction Digital Line Signalling System for Telephone Automatic Switching Network" GB/T 3971.3 "The Test Methods for the Technical Specifications of Multi-frequency Register Signaling for Telephone Automatic Switching Network" GB/T 5442 "The Test Methods for the Technical Specifications of Inband Pulsing Single Frequency Line Signalling System for Automatic Telephone Switching Network" GB/T 5444 "The Test Methods for the Technical Specifications of Subscriber Line Signalling for Automatic Telephone Switching Network" GB 6879 "Technical Requirements of the 30 Channels Pulse Code Modulation Multiplex Equipment at 2048 kbit/s" GB 12048 "Requirements for Clock and Synchronization Equipment Used in the Digital Network" GF 002-9002.1 "General Technical Specification for Telephone Switching Equipment of Ministry of Posts and Telecommunications" "The Technical System for Telephone Automatic Switching Network (Trail)" "Technical System of Digital and Analog Hybrid Network in Large- and Middle-sized Cities (Interim Provisions)" Red Book of CCITT-related suggestion Q.501-507 Q.511-517 Blue Book of CCITT-related suggestion Q.500 Q.511-513 Q.521-522 Q.541-544 Q.551-554 3 Public Testing Conditions 3.1 The equipment and apparatus like code pattern converter, digital echo suppressor, canceller, digital speech interpolation devices and full-zero suppressor shall not be connected in the connecting circuit under the testing. 3.2 Half connection testing method and index are adopted for the transmission index in principle. If the half connection testing conditions are not available, the full-connection testing method may be adopted.
Contents of YD/T 751-1995
1 Subject Contents and Application Scope 2 Normative References 3 Public Testing Conditions 4 Requirements for Testing Instruments and Equipment 5 Random Inspection Method and Original Testing Data Treatment Principle 6 Testing of Electrical Performance of Interfaces 7 Testing of Transmission Characteristics Index 8 Transmission Characteristics Testing and Interface Parameter between Digital Trunk Interfaces 9 Subscriber Signaling and Subscriber Line Condition 10 Interoffice Signaling System Test 11 Signal Tone and Ringing Current 12 Synchronous Performance Test 13 Basic Function Testing Additional Information:
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YD/T 751-1995, YD 751-1995, YDT 751-1995, YD/T751-1995, YD/T 751, YD/T751, YD751-1995, YD 751, YD751, YDT751-1995, YDT 751, YDT751