2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY 0118-2005
YY 0118-2005   Hip joint prostheses (English Version)
Standard No.: YY 0118-2005 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):100.0 remind me the price change

Email:

Implemented on:2006-12-1 Delivery: via email in 1 business day

→ → →

,2018-1-1,2006-12-1,141137478116054FD8DEC4BC02584
Standard No.: YY 0118-2005
English Name: Hip joint prostheses
Chinese Name: 髋关节假体
Chinese Classification: C35    Orthopedic devices
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.40 11.040.40    Implants for surgery, prosthetics and orthotics 11.040.40
Source Content Issued by: China Food and Drug Administration
Issued on: 2005-12-7
Implemented on: 2006-12-1
Status: superseded
Superseded by:YY 0118-2016 Joint replacement implants - Hip joint prostheses
Superseded on:2018-1-1
Superseding:YY 0118-1993 Hip joint prosthesis
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 100.0
Delivery: via email in 1 business day
1 Scope This standard specifies the definitions, classification, requirements, test methods, inspection rules, marking, packaging, instructions for use, transportation, storage and the like of total and partial hip joint replacements. This standard is applicable to the joint prostheses used for the total and partial hip joint replacement of human body. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding corrections to), or revisions of, any of these publications do not apply. However, the parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 2828.1 Sampling Procedures for Inspection by Attributes - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection (GB/T 2828.1-2003, ISO 2859-1, IDT) GB/T 2829 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB/T 14233.1 Test Methods for Infusion, Transfusion, Injection Equipments for Medical Use - Part 1: Chemical Analysis Methods GB/T 14233.2 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 2: Biological Test Methods GB/T 16886.7 Biological Evaluation of Medical Devices - Part 7: Ethylene Oxide Sterilization Residuals (GB/T 16886.7-2001, idt ISO 10993-7: 1995) GB/T 19701.2 Implants for Surgery Ultra-high Molecular Weight Polyethylene - Part 2: Moulded Forms (GB/T 19701.2-2005, ISO 5834-2: 1998, IDT) YY 0117 (All the parts) Implants for Surgery - Forgings, Castings for Bone Joint Prostheses YY 0341 General Technological Requirements for Non-active Metallic Surgery Implants of Osteosynthesis YY/T 0343 Liquid Penetrant Inspection of Metallic Surgical Implants (YY/T 0343-2002, ISO 9583: 1993, NEQ) ISO 6474 Implants for Surgery - Ceramic Materials Based on High Purity Alumina ISO 7206-1 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 1: Classification and Designation of Dimensions ISO 7206-2 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 2: Articulating Surfaces Made of Metallic, Ceramic and Plastics Materials ISO 7206-4 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 4: Determination of Endurance Properties and Performance of Stemmed Femoral Components ISO 7206-6 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 6: Endurance Properties Testing and Performance Requirements of Neck Region of Stemmed Femoral Components ISO 7206-8 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 8: Endurance Performance of Stemmed Femoral Components with Application of Torsion ISO 13356 Implants for Surgery - Ceramic Materials Based on Yttria-stabilized Tetragonal Zirconia (Y-TZP) ISO 13779-2 Implants for Surgery - Hydroxyapatite - Part 2: Coatings of Hydroxyapatite ISO 14242-1 Implants for Surgery - Wear of Total Hip-joint Prostheses - Part 1: Loading and Displacement Parameters for Wear-testing Machines and Corresponding Environmental Conditions for Test ISO 14242-2 Implants for Surgery - Wear of Total Hip-joint Prostheses - Part 2: Methods of Measurement ISO 21534 Non-active Surgical Implants - Joint Replacement Implants - Particular Requirements 3 Terms, Definitions and Classification 3.1 Terms and definitions For the purposes of this standard, the terms and definitions established in ISO 21534 and ISO 7206-1 and the following ones apply. 3.1.1 Hip joint replacement Implant used to replace one or both of the articulating surfaces of the hip joint. 3.1.2 Total hip joint replacement Implant comprising a femoral component and an acetabulum component intended to replace both of the articulating surfaces of the hip joints. 3.1.3 Partial hip joint replacement Implant comprising a femoral component intended to replace the femoral articulating surface of the hip joint. Note: partial hip joint replacement implants incorporate either a bipolar or a unipolar head. 3.1.4 Acetabulum replacement Implant comprising an acetabulum component intended to replace acetabulum articulating surface of the hip joint. 3.1.5 Femoral component Part of a total or partial hip joint replacement which is intended to be attached to the femur. 3.1.6 Acetabulum component Implant of monobloc or modular construction intended to be fixed to the prepared biological acetabulum. 3.1.7 Bipolar head Part of a femoral component with a concave (inner) surface intended to articulate with the spherical head of the femoral component and a convex (outer) spherical surface intended to articulate with the biological acetabulum. 3.1.8 Unipolar head Head of a femoral component intended to articulate with the biological acetabulum. 3.1.9 Module component Femoral or acetabulum component which is assembled by the user from a number of sub-components. 3.1.10 Monobloc component Femoral or acetabulum component which is supplied as a single unit. 3.2 Classification 3.2.1 Product classification The classification of hip joint prostheses according to product use and form is detailed in Table 1.
Foreword II 1 Scope 2 Normative References 3 Terms, Definitions and Classification 4 Requirements 5 Test Methods 6 Inspection Rules 7 Instructions for Use 8 Marking 9 Packaging 10 Transportation and Storage Appendix A (Normative) List of Material Standards Found Acceptable for the Manufacture of Hip Joint Prostheses Appendix B (Normative) List of Materials Found Acceptable or not Acceptable for the Manufacture of Articulating Surfaces of Hip Joint Prostheses Appendix C (Normative) List of Materials Found Acceptable or Non-acceptable for Metallic Combinations for Non-articulating Contacting Surfaces of Hip Joint Prostheses Bibliography
Referred in YY 0118-2005:
*GB/T 2828.1-2012 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability)
*GB/T 14233.1-2008 Test methods for infusion transfusion injection equipments for medical use - Part 1: Chemical analysis methods
*GB/T 14233.2-2005 Test methods for infusion, transfusion, injection equipment for medical use-Part 2: Biological test methods
*GB/T 16886.7-2015 Biological evaluation of medical devices—Part 7: Ethylene oxide sterilization residuals
*GB/T 19701.2-2016 Implants for surgery-Ultra-high-molecular-weight polyethylene- Part 2:Moulded forms
*YY0117-2005
*YY 0341-2009 General technological requirements for non-active metallic surgical implants for osteosynthesis
*YY/T 0343-2002 Liquid penetrant inspection of metallic surgical implants
Code of China
Standard
YY 0118-2005  Hip joint prostheses (English Version)
Standard No.YY 0118-2005
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)100.0
Implemented on2006-12-1
Deliveryvia email in 1 business day
Detail of YY 0118-2005
Standard No.
YY 0118-2005
English Name
Hip joint prostheses
Chinese Name
髋关节假体
Chinese Classification
C35
Professional Classification
YY
ICS Classification
Issued by
China Food and Drug Administration
Issued on
2005-12-7
Implemented on
2006-12-1
Status
superseded
Superseded by
YY 0118-2016 Joint replacement implants - Hip joint prostheses
Superseded on
2018-1-1
Abolished on
Superseding
YY 0118-1993 Hip joint prosthesis
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
100.0
Keywords
YY 0118-2005, YY/T 0118-2005, YYT 0118-2005, YY0118-2005, YY 0118, YY0118, YY/T0118-2005, YY/T 0118, YY/T0118, YYT0118-2005, YYT 0118, YYT0118
Introduction of YY 0118-2005
1 Scope This standard specifies the definitions, classification, requirements, test methods, inspection rules, marking, packaging, instructions for use, transportation, storage and the like of total and partial hip joint replacements. This standard is applicable to the joint prostheses used for the total and partial hip joint replacement of human body. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding corrections to), or revisions of, any of these publications do not apply. However, the parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 2828.1 Sampling Procedures for Inspection by Attributes - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection (GB/T 2828.1-2003, ISO 2859-1, IDT) GB/T 2829 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB/T 14233.1 Test Methods for Infusion, Transfusion, Injection Equipments for Medical Use - Part 1: Chemical Analysis Methods GB/T 14233.2 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 2: Biological Test Methods GB/T 16886.7 Biological Evaluation of Medical Devices - Part 7: Ethylene Oxide Sterilization Residuals (GB/T 16886.7-2001, idt ISO 10993-7: 1995) GB/T 19701.2 Implants for Surgery Ultra-high Molecular Weight Polyethylene - Part 2: Moulded Forms (GB/T 19701.2-2005, ISO 5834-2: 1998, IDT) YY 0117 (All the parts) Implants for Surgery - Forgings, Castings for Bone Joint Prostheses YY 0341 General Technological Requirements for Non-active Metallic Surgery Implants of Osteosynthesis YY/T 0343 Liquid Penetrant Inspection of Metallic Surgical Implants (YY/T 0343-2002, ISO 9583: 1993, NEQ) ISO 6474 Implants for Surgery - Ceramic Materials Based on High Purity Alumina ISO 7206-1 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 1: Classification and Designation of Dimensions ISO 7206-2 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 2: Articulating Surfaces Made of Metallic, Ceramic and Plastics Materials ISO 7206-4 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 4: Determination of Endurance Properties and Performance of Stemmed Femoral Components ISO 7206-6 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 6: Endurance Properties Testing and Performance Requirements of Neck Region of Stemmed Femoral Components ISO 7206-8 Implants for Surgery - Partial and Total Hip Joint Prostheses - Part 8: Endurance Performance of Stemmed Femoral Components with Application of Torsion ISO 13356 Implants for Surgery - Ceramic Materials Based on Yttria-stabilized Tetragonal Zirconia (Y-TZP) ISO 13779-2 Implants for Surgery - Hydroxyapatite - Part 2: Coatings of Hydroxyapatite ISO 14242-1 Implants for Surgery - Wear of Total Hip-joint Prostheses - Part 1: Loading and Displacement Parameters for Wear-testing Machines and Corresponding Environmental Conditions for Test ISO 14242-2 Implants for Surgery - Wear of Total Hip-joint Prostheses - Part 2: Methods of Measurement ISO 21534 Non-active Surgical Implants - Joint Replacement Implants - Particular Requirements 3 Terms, Definitions and Classification 3.1 Terms and definitions For the purposes of this standard, the terms and definitions established in ISO 21534 and ISO 7206-1 and the following ones apply. 3.1.1 Hip joint replacement Implant used to replace one or both of the articulating surfaces of the hip joint. 3.1.2 Total hip joint replacement Implant comprising a femoral component and an acetabulum component intended to replace both of the articulating surfaces of the hip joints. 3.1.3 Partial hip joint replacement Implant comprising a femoral component intended to replace the femoral articulating surface of the hip joint. Note: partial hip joint replacement implants incorporate either a bipolar or a unipolar head. 3.1.4 Acetabulum replacement Implant comprising an acetabulum component intended to replace acetabulum articulating surface of the hip joint. 3.1.5 Femoral component Part of a total or partial hip joint replacement which is intended to be attached to the femur. 3.1.6 Acetabulum component Implant of monobloc or modular construction intended to be fixed to the prepared biological acetabulum. 3.1.7 Bipolar head Part of a femoral component with a concave (inner) surface intended to articulate with the spherical head of the femoral component and a convex (outer) spherical surface intended to articulate with the biological acetabulum. 3.1.8 Unipolar head Head of a femoral component intended to articulate with the biological acetabulum. 3.1.9 Module component Femoral or acetabulum component which is assembled by the user from a number of sub-components. 3.1.10 Monobloc component Femoral or acetabulum component which is supplied as a single unit. 3.2 Classification 3.2.1 Product classification The classification of hip joint prostheses according to product use and form is detailed in Table 1.
Contents of YY 0118-2005
Foreword II 1 Scope 2 Normative References 3 Terms, Definitions and Classification 4 Requirements 5 Test Methods 6 Inspection Rules 7 Instructions for Use 8 Marking 9 Packaging 10 Transportation and Storage Appendix A (Normative) List of Material Standards Found Acceptable for the Manufacture of Hip Joint Prostheses Appendix B (Normative) List of Materials Found Acceptable or not Acceptable for the Manufacture of Articulating Surfaces of Hip Joint Prostheses Appendix C (Normative) List of Materials Found Acceptable or Non-acceptable for Metallic Combinations for Non-articulating Contacting Surfaces of Hip Joint Prostheses Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY 0118-2005, YY/T 0118-2005, YYT 0118-2005, YY0118-2005, YY 0118, YY0118, YY/T0118-2005, YY/T 0118, YY/T0118, YYT0118-2005, YYT 0118, YYT0118