2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY 0592-2005
YY 0592-2005   High intensity focused ultrasound therapy system (English Version)
Standard No.: YY 0592-2005 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:2006-12-1 Delivery: via email in 1 business day

→ → →

,2018-1-1,2006-12-1,14113747830361ABAF183F6FAE9CF
Standard No.: YY 0592-2005
English Name: High intensity focused ultrasound therapy system
Chinese Name: 高强度聚焦超声(HIFU)治疗系统
Chinese Classification: C41    Medical ultrasound, laser, high-frequency instrument and equipment
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.50 11.040.50    Radiographic equipment 11.040.50
Source Content Issued by: China Food and Drug Administration
Issued on: 2005-12-7
Implemented on: 2006-12-1
Status: superseded
Superseded by:YY 0592-2016 High intensity focused ultrasound therapy system
Superseded on:2018-1-1
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
1 Scope This standard specifies terms and definitions, classification, requirements, test methods, inspection rules as well as marking, packaging, transportation and storage of high intensity focused ultrasound therapy system. This standard is applicable to high intensity focused (extracorporeal) ultrasound therapy system (hereafter referred to as HIFU therapy system) with sound working frequency range of 0.5 MHz~2.0 MHz. 2 Normative References The following documents contain provisions which, by reference into this document, constitute the provisions of this document. For dated references, subsequent amendments to (excluding correction contents), or revisions of, any of these publications do not apply. However, it is encouraged that the Parties that reach an agreement according to this standard should research whether the latest edition of these documents can be used. For undated references, the latest edition referred to applies. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods GB/T 3947-1996 Acoustical Terminology GB 9706.1-1995 Medical Electrical Equipment - Part 1: General Requirements for Safety (idt IEC 60601:1988) GB 9706.15-1999 Medical Electrical Equipment - Part 1: General Requirements for Safety - 1. Collateral Standard: Safety Requirements for Medical Electrical Systems GB 10152-1997 B Mode Ultrasonic Diagnostic Equipment GB/T 14710-1993 The Environmental Requirements and Test Methods for Medical Electrical Equipment GB/T 16540-1996 Acoustics-Measurement and Characterisation of Ultrasonic Fields in the Frequency Range 0.5 MHz to 15MHz-Hydrophone Method GB/T 19890-2005 Acoustics-High Intensity Focused Ultrasound(HIFU)-Measurements of Acoustic Power and Field Characteristics 3 Terms and Definitions For the purposes of this standard, the terms and definitions specified in GB/T 3947-1996, GB/T 16540-1996 and GB/T 19890-2005 as well as those listed below apply. 3.1 high intensity focused ultrasound therapy system the therapy system (hereinafter referred to as HIFU therapy system), in which the ultrasound sent out by the focusing ultrasound sound source composed of single-element or multi-element transducer array penetrates through patients' body surface at the sound (acoustic) intensity acceptable for human's normal structure after passing through acoustic transmission medium, gathers energy on target tissue to cause its coagulative necrosis (or instant inactivation).
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification 5 Requirements 6 Test Method 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Annex A (Normative) Safety
Code of China
Standard
YY 0592-2005  High intensity focused ultrasound therapy system (English Version)
Standard No.YY 0592-2005
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on2006-12-1
Deliveryvia email in 1 business day
Detail of YY 0592-2005
Standard No.
YY 0592-2005
English Name
High intensity focused ultrasound therapy system
Chinese Name
高强度聚焦超声(HIFU)治疗系统
Chinese Classification
C41
Professional Classification
YY
ICS Classification
Issued by
China Food and Drug Administration
Issued on
2005-12-7
Implemented on
2006-12-1
Status
superseded
Superseded by
YY 0592-2016 High intensity focused ultrasound therapy system
Superseded on
2018-1-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
YY 0592-2005, YY/T 0592-2005, YYT 0592-2005, YY0592-2005, YY 0592, YY0592, YY/T0592-2005, YY/T 0592, YY/T0592, YYT0592-2005, YYT 0592, YYT0592
Introduction of YY 0592-2005
1 Scope This standard specifies terms and definitions, classification, requirements, test methods, inspection rules as well as marking, packaging, transportation and storage of high intensity focused ultrasound therapy system. This standard is applicable to high intensity focused (extracorporeal) ultrasound therapy system (hereafter referred to as HIFU therapy system) with sound working frequency range of 0.5 MHz~2.0 MHz. 2 Normative References The following documents contain provisions which, by reference into this document, constitute the provisions of this document. For dated references, subsequent amendments to (excluding correction contents), or revisions of, any of these publications do not apply. However, it is encouraged that the Parties that reach an agreement according to this standard should research whether the latest edition of these documents can be used. For undated references, the latest edition referred to applies. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods GB/T 3947-1996 Acoustical Terminology GB 9706.1-1995 Medical Electrical Equipment - Part 1: General Requirements for Safety (idt IEC 60601:1988) GB 9706.15-1999 Medical Electrical Equipment - Part 1: General Requirements for Safety - 1. Collateral Standard: Safety Requirements for Medical Electrical Systems GB 10152-1997 B Mode Ultrasonic Diagnostic Equipment GB/T 14710-1993 The Environmental Requirements and Test Methods for Medical Electrical Equipment GB/T 16540-1996 Acoustics-Measurement and Characterisation of Ultrasonic Fields in the Frequency Range 0.5 MHz to 15MHz-Hydrophone Method GB/T 19890-2005 Acoustics-High Intensity Focused Ultrasound(HIFU)-Measurements of Acoustic Power and Field Characteristics 3 Terms and Definitions For the purposes of this standard, the terms and definitions specified in GB/T 3947-1996, GB/T 16540-1996 and GB/T 19890-2005 as well as those listed below apply. 3.1 high intensity focused ultrasound therapy system the therapy system (hereinafter referred to as HIFU therapy system), in which the ultrasound sent out by the focusing ultrasound sound source composed of single-element or multi-element transducer array penetrates through patients' body surface at the sound (acoustic) intensity acceptable for human's normal structure after passing through acoustic transmission medium, gathers energy on target tissue to cause its coagulative necrosis (or instant inactivation).
Contents of YY 0592-2005
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification 5 Requirements 6 Test Method 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Annex A (Normative) Safety
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY 0592-2005, YY/T 0592-2005, YYT 0592-2005, YY0592-2005, YY 0592, YY0592, YY/T0592-2005, YY/T 0592, YY/T0592, YYT0592-2005, YYT 0592, YYT0592