2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 0314-2021
YY/T 0314-2021   Single-use containers for human venous blood specimen collection (English Version)
Standard No.: YY/T 0314-2021 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9500 words Translation Price(USD):315.0 remind me the price change

Email:

Implemented on:2022-9-1 Delivery: via email in 1 business day

→ → →

,,2022-9-1,8F0D8B177D412AEC1631257985516
Standard No.: YY/T 0314-2021
English Name: Single-use containers for human venous blood specimen collection
Chinese Name: 一次性使用人体静脉血样采集容器
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.120.20 11.120.20    Wound dressings and compresses 11.120.20
Source Content Issued by: National Medical Products Adminstration
Issued on: 2021-09-06
Implemented on: 2022-9-1
Status: valid
Superseding:YY/T 0314-2007
YY/T 0314-2007/XG1-2013 Single-use containers for human venous blood specimen collection, includes Amendment 1
Target Language: English
File Format: PDF
Word Count: 9500 words
Translation Price(USD): 315.0
Delivery: via email in 1 business day
Single-use containers for human venous blood specimen collection 1 Scope This standard specifies requirements and test methods for evacuated and non-evacuated single-use containers for human venous blood specimen collection (hereinafter referred to as “container”). This standard is applicable to evacuated and non-evacuated single-use containers for human venous blood specimen collection. It does not specify requirements for blood collection needles and needle holders, and it is not applicable to blood culture receptacles or “arterial” blood gas collection devices that can be used for venous blood. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition (including any amendment) applies. GB/T 6682 Water for analytical laboratory use - Specification and test methods (GB/T 6682-2008, ISO 3696:1987, MOD) YY/T 0466.1 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements (YY/T 0466.1-2016, ISO 15223-1:2012, IDT) 3 Terms and definitions For the purpose of this document, the following terms and definitions apply. 3.1 accessory component inside the container which is intended by the manufacturer to assist in the collection, or mixing, or separation of the specimen Note: Examples of accessories are small plastic inert balls or a separate gel found in a serum or plasma container designed to separate the serum or plasma from the cells after centrifugation.   3.2 additive substance (other than inside surface treatments designed to be irremovable) that is placed in the container in order to facilitate the creation of the desired sample 3.3 closure component by which the container is sealed, which may consist of several parts 3.4 container vessel, whether evacuated or not, intended to contain a specimen, together with any container accessory and additive, with closure in place 3.5 container interior inner surface of the container exposed to the specimen 3.6 draw volume volume of whole blood that will be collected in the container 3.7 evacuated container container intended for blood collection by means of evacuation either already induced by the manufacturer (i.e. pre-evacuated containers) or induced by the user before or during blood collection 3.8 expiry date date after which the product shall not be used 3.9 fill indicator line marked on a tube or its label to indicate the correct filling 3.10 free space space above the drawn sample 3.11 nominal liquid capacity draw volume plus volume of additive not including any accessories 3.12 primary colour dominant colour of closure component most representative of the additive in the container Note: Dominant is the colour of the closure that covers the majority of the surface. 3.13 primary pack smallest package of containers 3.14 relative centrifugal force; RCF force that is generated during the sample centrifugation process, which is specified by the manufacturer for adequate separation 3.15 specimen venous blood collected in a container 3.16 tube part of the container, without the closure, that contains the specimen 3.17 visual inspection inspection by an observer with normal or corrected-to-normal vision without magnification under a uniform illuminance between 500 lx and 1,000 lx 4 Materials 4.1 The tube shall be made of material which allows a clear view of the contents when subjected to visual inspection, unless exposure to ultraviolet light or visible light would degrade the contents. 4.2 If a container is intended specifically for the determination of a certain element/substance, the maximum level of the element/substance in the container interior and the analytical method employed shall be stated by the manufacturer in supporting literature or on the label or packaging (see also 10.4). For the determination of specified metals and other specified substances, the formulation of the closure material shall be such as not to interfere with the determination thereby affecting the results. For highly sensitive determinations (for example those using fluorimetry) or little-used tests, limits of interference may not have been agreed on. In such cases, the laboratory should establish a blank value and consult the manufacturer. 4.3 The container shall be free from foreign matter when subjected to visual inspection.
Foreword i Introduction iv 1 Scope 2 Normative references 3 Terms and definitions 4 Materials 5 Draw volume 6 Design 7 Construction 8 Sterility and special microbiological states 9 Additives 10 Marking and labeling 11 Container identification Annex A (Normative) Draw volume test for non-evacuated containers Annex B (Normative) Draw volume test for evacuated container Annex C (Normative) Test for leakage of container Annex D (Normative) Test for robustness of the container Annex E (Informative) Concentrations of additives and volume of liquid additives Annex F (Informative) Recommended colour codes for identifying additives and accessories Annex G (Informative) Recommended method for calibrating ambient pressure Annex H (Informative) Test method for draw volume of pre-evacuated containers used in high altitude areas Bibliography
Referred in YY/T 0314-2021:
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
*YY/T 0466.1-2016 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
Code of China
Standard
YY/T 0314-2021  Single-use containers for human venous blood specimen collection (English Version)
Standard No.YY/T 0314-2021
Statusvalid
LanguageEnglish
File FormatPDF
Word Count9500 words
Price(USD)315.0
Implemented on2022-9-1
Deliveryvia email in 1 business day
Detail of YY/T 0314-2021
Standard No.
YY/T 0314-2021
English Name
Single-use containers for human venous blood specimen collection
Chinese Name
一次性使用人体静脉血样采集容器
Chinese Classification
Professional Classification
YY
ICS Classification
Issued by
National Medical Products Adminstration
Issued on
2021-09-06
Implemented on
2022-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
YY/T 0314-2007
YY/T 0314-2007/XG1-2013 Single-use containers for human venous blood specimen collection, includes Amendment 1
Language
English
File Format
PDF
Word Count
9500 words
Price(USD)
315.0
Keywords
YY/T 0314-2021, YY 0314-2021, YYT 0314-2021, YY/T0314-2021, YY/T 0314, YY/T0314, YY0314-2021, YY 0314, YY0314, YYT0314-2021, YYT 0314, YYT0314
Introduction of YY/T 0314-2021
Single-use containers for human venous blood specimen collection 1 Scope This standard specifies requirements and test methods for evacuated and non-evacuated single-use containers for human venous blood specimen collection (hereinafter referred to as “container”). This standard is applicable to evacuated and non-evacuated single-use containers for human venous blood specimen collection. It does not specify requirements for blood collection needles and needle holders, and it is not applicable to blood culture receptacles or “arterial” blood gas collection devices that can be used for venous blood. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition (including any amendment) applies. GB/T 6682 Water for analytical laboratory use - Specification and test methods (GB/T 6682-2008, ISO 3696:1987, MOD) YY/T 0466.1 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements (YY/T 0466.1-2016, ISO 15223-1:2012, IDT) 3 Terms and definitions For the purpose of this document, the following terms and definitions apply. 3.1 accessory component inside the container which is intended by the manufacturer to assist in the collection, or mixing, or separation of the specimen Note: Examples of accessories are small plastic inert balls or a separate gel found in a serum or plasma container designed to separate the serum or plasma from the cells after centrifugation.   3.2 additive substance (other than inside surface treatments designed to be irremovable) that is placed in the container in order to facilitate the creation of the desired sample 3.3 closure component by which the container is sealed, which may consist of several parts 3.4 container vessel, whether evacuated or not, intended to contain a specimen, together with any container accessory and additive, with closure in place 3.5 container interior inner surface of the container exposed to the specimen 3.6 draw volume volume of whole blood that will be collected in the container 3.7 evacuated container container intended for blood collection by means of evacuation either already induced by the manufacturer (i.e. pre-evacuated containers) or induced by the user before or during blood collection 3.8 expiry date date after which the product shall not be used 3.9 fill indicator line marked on a tube or its label to indicate the correct filling 3.10 free space space above the drawn sample 3.11 nominal liquid capacity draw volume plus volume of additive not including any accessories 3.12 primary colour dominant colour of closure component most representative of the additive in the container Note: Dominant is the colour of the closure that covers the majority of the surface. 3.13 primary pack smallest package of containers 3.14 relative centrifugal force; RCF force that is generated during the sample centrifugation process, which is specified by the manufacturer for adequate separation 3.15 specimen venous blood collected in a container 3.16 tube part of the container, without the closure, that contains the specimen 3.17 visual inspection inspection by an observer with normal or corrected-to-normal vision without magnification under a uniform illuminance between 500 lx and 1,000 lx 4 Materials 4.1 The tube shall be made of material which allows a clear view of the contents when subjected to visual inspection, unless exposure to ultraviolet light or visible light would degrade the contents. 4.2 If a container is intended specifically for the determination of a certain element/substance, the maximum level of the element/substance in the container interior and the analytical method employed shall be stated by the manufacturer in supporting literature or on the label or packaging (see also 10.4). For the determination of specified metals and other specified substances, the formulation of the closure material shall be such as not to interfere with the determination thereby affecting the results. For highly sensitive determinations (for example those using fluorimetry) or little-used tests, limits of interference may not have been agreed on. In such cases, the laboratory should establish a blank value and consult the manufacturer. 4.3 The container shall be free from foreign matter when subjected to visual inspection.
Contents of YY/T 0314-2021
Foreword i Introduction iv 1 Scope 2 Normative references 3 Terms and definitions 4 Materials 5 Draw volume 6 Design 7 Construction 8 Sterility and special microbiological states 9 Additives 10 Marking and labeling 11 Container identification Annex A (Normative) Draw volume test for non-evacuated containers Annex B (Normative) Draw volume test for evacuated container Annex C (Normative) Test for leakage of container Annex D (Normative) Test for robustness of the container Annex E (Informative) Concentrations of additives and volume of liquid additives Annex F (Informative) Recommended colour codes for identifying additives and accessories Annex G (Informative) Recommended method for calibrating ambient pressure Annex H (Informative) Test method for draw volume of pre-evacuated containers used in high altitude areas Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0314-2021, YY 0314-2021, YYT 0314-2021, YY/T0314-2021, YY/T 0314, YY/T0314, YY0314-2021, YY 0314, YY0314, YYT0314-2021, YYT 0314, YYT0314