YY/T 0506.2-2016   Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment- Part 2:Performance requirements and test methods (English Version)
Standard No.: YY/T 0506.2-2016 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):130.0 remind me the price change

Email:

Implemented on:2017-1-1 Delivery: via email in 1 business day

→ → →

,2024-1-15,2017-1-1,5423138B9255612F1469083493781
Standard No.: YY/T 0506.2-2016
English Name: Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment- Part 2:Performance requirements and test methods
Chinese Name: 病人、医护人员和器械用手术单、手术衣和洁净服 第2部分:性能要求和试验方法
Professional Classification: YY    Professional Standard - Pharmaceutics
Source Content Issued by: China Food and Drug Adminstration
Issued on: 2016-01-26
Implemented on: 2017-1-1
Status: superseded
Superseded by:YY/T 0506.1-2023 Surgical drapes,gowns and clean air suits for medical use-Part 1:General requirements
Superseded on:2024-1-15
Superseding:YY/T 0506.2-2009 Surgical drapes,gowns and clean air suits for patients,clinical staff and equipment—Part 2:Performance requirements and performance levels
YY/T 0506.3-2005 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment-Part 3: test methods
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 130.0
Delivery: via email in 1 business day
Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment— Part 2: Performance requirements and test methods 1 Scope This part of YY/T 0506 specifies the performance requirements and test methods for surgical drapes, gowns and clean air suits. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 4744 Textile fabrics—Determination of resistance to water penetration—Hydro static pressure test GB/T 6529 Textiles—Standard atmospheres for conditioning and testing GB/T 7742.1 Textiles—Bursting properties of fabrics—Part 1: Hydraulic method for determination of bursting strength and bursting distension GB/T 24218.3 Textiles—Test methods for nonwovens—Part 3: Determination of tensile strength and elongation (strip method) YY/T 0506.1 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 2: Performance requirements and test methods YY/T 0506.4 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 4: Test method for linting in the dry state YY/T 0506.5 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 5: Test method for resistance to dry microbial penetration YY/T 0506.6 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 6: Test method to determine the resistance to wet bacterial penetration YY/T 0506.7 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 7: Test methods for determination of cleanliness-microbial 3 Terms and definitions For the purposes of this standard, the terms and definitions specified in YY/T 0506.1 as well as the followings apply. 3.1 cfu (colony forming unit) unit by which the culturable number of microorganisms is expressed Note: The culturable number is the number of microorganisms, single cells or aggregates, able to form colonies on solid nutrient medium. 3.2 less critical product area product area with less likely to be involved in the transfer of infective agents to or from the wound, e.g. back of surgical gowns Note 1: See YY/T 0506.1 for the definition of critical product area. Note 2: If the manufacturer distinguishes between critical product area and less critical product area, the manufacturer is required by YY/T 0506.1 to identify these areas and provide explanatory information on the difference upon request. For additional information, see YY/T 0506.1. 3.3 performance level discrete standard defined to classify products according to the performance requirements of this part Note: Within the introduction of two performance levels, YY/T 0506 series standards acknowledge the fact that products are challenged to differing extents during surgical procedures, dependent upon the duration, mechanical stress and liquid challenge.
Foreword i Introduction iii 1 Scope 2 Normative references 3 Terms and definitions 4 Performance requirements Annex A (Normative) Test methods Annex B (Informative) Optional test methods Bibliography
YY/T 0506.2-2016 is referred in:
*YY/T 0506.8-2019 Surgical drapes,gowns and clean air suits for patients, clinical staff and equipment—Part 8:Special requirements for products
Code of China
Standard
YY/T 0506.2-2016  Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment- Part 2:Performance requirements and test methods (English Version)
Standard No.YY/T 0506.2-2016
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)130.0
Implemented on2017-1-1
Deliveryvia email in 1 business day
Detail of YY/T 0506.2-2016
Standard No.
YY/T 0506.2-2016
English Name
Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment- Part 2:Performance requirements and test methods
Chinese Name
病人、医护人员和器械用手术单、手术衣和洁净服 第2部分:性能要求和试验方法
Chinese Classification
Professional Classification
YY
ICS Classification
Issued by
China Food and Drug Adminstration
Issued on
2016-01-26
Implemented on
2017-1-1
Status
superseded
Superseded by
YY/T 0506.1-2023 Surgical drapes,gowns and clean air suits for medical use-Part 1:General requirements
Superseded on
2024-1-15
Abolished on
Superseding
YY/T 0506.2-2009 Surgical drapes,gowns and clean air suits for patients,clinical staff and equipment—Part 2:Performance requirements and performance levels
YY/T 0506.3-2005 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment-Part 3: test methods
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
130.0
Keywords
YY/T 0506.2-2016, YY 0506.2-2016, YYT 0506.2-2016, YY/T0506.2-2016, YY/T 0506.2, YY/T0506.2, YY0506.2-2016, YY 0506.2, YY0506.2, YYT0506.2-2016, YYT 0506.2, YYT0506.2
Introduction of YY/T 0506.2-2016
Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment— Part 2: Performance requirements and test methods 1 Scope This part of YY/T 0506 specifies the performance requirements and test methods for surgical drapes, gowns and clean air suits. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 4744 Textile fabrics—Determination of resistance to water penetration—Hydro static pressure test GB/T 6529 Textiles—Standard atmospheres for conditioning and testing GB/T 7742.1 Textiles—Bursting properties of fabrics—Part 1: Hydraulic method for determination of bursting strength and bursting distension GB/T 24218.3 Textiles—Test methods for nonwovens—Part 3: Determination of tensile strength and elongation (strip method) YY/T 0506.1 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 2: Performance requirements and test methods YY/T 0506.4 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 4: Test method for linting in the dry state YY/T 0506.5 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 5: Test method for resistance to dry microbial penetration YY/T 0506.6 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 6: Test method to determine the resistance to wet bacterial penetration YY/T 0506.7 Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment—Part 7: Test methods for determination of cleanliness-microbial 3 Terms and definitions For the purposes of this standard, the terms and definitions specified in YY/T 0506.1 as well as the followings apply. 3.1 cfu (colony forming unit) unit by which the culturable number of microorganisms is expressed Note: The culturable number is the number of microorganisms, single cells or aggregates, able to form colonies on solid nutrient medium. 3.2 less critical product area product area with less likely to be involved in the transfer of infective agents to or from the wound, e.g. back of surgical gowns Note 1: See YY/T 0506.1 for the definition of critical product area. Note 2: If the manufacturer distinguishes between critical product area and less critical product area, the manufacturer is required by YY/T 0506.1 to identify these areas and provide explanatory information on the difference upon request. For additional information, see YY/T 0506.1. 3.3 performance level discrete standard defined to classify products according to the performance requirements of this part Note: Within the introduction of two performance levels, YY/T 0506 series standards acknowledge the fact that products are challenged to differing extents during surgical procedures, dependent upon the duration, mechanical stress and liquid challenge.
Contents of YY/T 0506.2-2016
Foreword i Introduction iii 1 Scope 2 Normative references 3 Terms and definitions 4 Performance requirements Annex A (Normative) Test methods Annex B (Informative) Optional test methods Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0506.2-2016, YY 0506.2-2016, YYT 0506.2-2016, YY/T0506.2-2016, YY/T 0506.2, YY/T0506.2, YY0506.2-2016, YY 0506.2, YY0506.2, YYT0506.2-2016, YYT 0506.2, YYT0506.2