2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 0908-2013
YY/T 0908-2013   Single-use filter for syringe (English Version)
Standard No.: YY/T 0908-2013 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):100.0 remind me the price change

Email:

Implemented on:2014-10-1 Delivery: via email in 1 business day

→ → →

,,2014-10-1,14113792985390F00EED0E1E9EB89
Standard No.: YY/T 0908-2013
English Name: Single-use filter for syringe
Chinese Name: 一次性使用注射用过滤器
Chinese Classification: C31    General and microsurgical devices
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.20 11.040.20    Transfusion, infusion and injection equipment 11.040.20
Source Content Issued by: SDA
Issued on: 2013-10-21
Implemented on: 2014-10-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 100.0
Delivery: via email in 1 business day
1 Scope This standard specifies classification and marking, materials, physical, chemical and biological requirements, marking and packaging of single-use filter for syringe. This standard is applicable to single-use filter for syringe (hereinafter referred to as filter); the filter, used together with syringe, is applied to muscle injection and intravenous injection of medicine in clinical treatment, addition of medicine to liquid bottle, and filtration of insoluble particles in chemical liquid. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. GB/T 1962.1 The Conical Fittings with a 6% (Luer) Taper for Syringes, Needles and Certain Other Medical Equipment - Part 1: General Requirement GB/T 1962.2 The Conical Fittings with a 6% (Luer) Taper For Syringes, Needles and Certain Other Medical Equipment - Part 2: Lock Fittings GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods GB 8368 Infusion Sets for Single Use - Gravity Feed GB/T 14233.1-2008 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 1: Chemical Analysis Methods GB/T 14233.2 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 2: Biological Test Methods GB 15810 Sterile Hypodermic Syringes for Single Use GB/T 16886.1 Biological Evaluation of Medical Devices - Part 1: Evaluation and Testing within a Risk Management Process YY 0321.3 Single-use Filter for Anesthesia YY/T 0466.1 Medical Devices - Symbols to be Used with Medical Device Labels Labelling and Information to be Supplied - Part 1: General Requirements YY 0770.1 Filter Material for Medical Infusion Equipment - Part 1: Fluid Filter Material 3 Classification and Marking
Foreword I 1 Scope 2 Normative References 3 Classification and Marking 4 Materials 5 Physical Requirements 6 Chemical Requirements 7 Biological Requirements 8 Marking 9 Package Appendix A (Normative Appendix) Physical Test Appendix B (Normative Appendix) Rules for Inspection Test
Referred in YY/T 0908-2013:
* GB/T 1962.1-2001 Conical fittings with a 6%(Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement
* GB/T 1962.2-2001 Conical fittings with a 6%(Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings
* GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
* GB 8368-2005 Infusion sets for single use, gravity feed
* GB/T 14233.1-2008 Test methods for infusion transfusion injection equipments for medical use - Part 1: Chemical analysis methods
* GB/T 14233.2-2005 Test methods for infusion, transfusion, injection equipment for medical use-Part 2: Biological test methods
* GB 15810-2001 Sterile hypodermic syringes for single use
* GB/T 16886.1-2011 Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
* YY 0321.3-2009 Single-use filter for anaesthesia
* YY/T 0466.1-2009 devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
* YY 0770.1-2009 Filter material for medical infusion equipments.Part 1:Fluid filter material
Code of China
Standard
YY/T 0908-2013  Single-use filter for syringe (English Version)
Standard No.YY/T 0908-2013
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)100.0
Implemented on2014-10-1
Deliveryvia email in 1 business day
Detail of YY/T 0908-2013
Standard No.
YY/T 0908-2013
English Name
Single-use filter for syringe
Chinese Name
一次性使用注射用过滤器
Chinese Classification
C31
Professional Classification
YY
ICS Classification
Issued by
SDA
Issued on
2013-10-21
Implemented on
2014-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
100.0
Keywords
YY/T 0908-2013, YY 0908-2013, YYT 0908-2013, YY/T0908-2013, YY/T 0908, YY/T0908, YY0908-2013, YY 0908, YY0908, YYT0908-2013, YYT 0908, YYT0908
Introduction of YY/T 0908-2013
1 Scope This standard specifies classification and marking, materials, physical, chemical and biological requirements, marking and packaging of single-use filter for syringe. This standard is applicable to single-use filter for syringe (hereinafter referred to as filter); the filter, used together with syringe, is applied to muscle injection and intravenous injection of medicine in clinical treatment, addition of medicine to liquid bottle, and filtration of insoluble particles in chemical liquid. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendments) applies. GB/T 1962.1 The Conical Fittings with a 6% (Luer) Taper for Syringes, Needles and Certain Other Medical Equipment - Part 1: General Requirement GB/T 1962.2 The Conical Fittings with a 6% (Luer) Taper For Syringes, Needles and Certain Other Medical Equipment - Part 2: Lock Fittings GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods GB 8368 Infusion Sets for Single Use - Gravity Feed GB/T 14233.1-2008 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 1: Chemical Analysis Methods GB/T 14233.2 Test Methods for Infusion, Transfusion, Injection Equipment for Medical Use - Part 2: Biological Test Methods GB 15810 Sterile Hypodermic Syringes for Single Use GB/T 16886.1 Biological Evaluation of Medical Devices - Part 1: Evaluation and Testing within a Risk Management Process YY 0321.3 Single-use Filter for Anesthesia YY/T 0466.1 Medical Devices - Symbols to be Used with Medical Device Labels Labelling and Information to be Supplied - Part 1: General Requirements YY 0770.1 Filter Material for Medical Infusion Equipment - Part 1: Fluid Filter Material 3 Classification and Marking
Contents of YY/T 0908-2013
Foreword I 1 Scope 2 Normative References 3 Classification and Marking 4 Materials 5 Physical Requirements 6 Chemical Requirements 7 Biological Requirements 8 Marking 9 Package Appendix A (Normative Appendix) Physical Test Appendix B (Normative Appendix) Rules for Inspection Test
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0908-2013, YY 0908-2013, YYT 0908-2013, YY/T0908-2013, YY/T 0908, YY/T0908, YY0908-2013, YY 0908, YY0908, YYT0908-2013, YYT 0908, YYT0908