2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 1711-2020
YY/T 1711-2020   Gating interface used in radiation therapy (English Version)
Standard No.: YY/T 1711-2020 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):165.0 remind me the price change

Email:

Implemented on:2022-6-1 Delivery: via email in 1 business day

→ → →

,,2022-6-1,B518CC21469B55A51594817234849
Standard No.: YY/T 1711-2020
English Name: Gating interface used in radiation therapy
Chinese Name: 放射治疗用门控接口
Chinese Classification: C43    Medical radiographic equipment
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.50 11.040.50    Radiographic equipment 11.040.50
Source Content Issued by: National Medical Products Adminstration
Issued on: 2020-06-30
Implemented on: 2022-6-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 165.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This standard was proposed by the National Medical Products Administration of the People’s Republic of China. This standard is under the jurisdiction of Subcommittee on Radiation Therapy, Nuclear Medicine and Radiodosimetry Equipment of National Technical Committee on Medical Electrical Equipment of Standardization Administration of China (SAC/TC 10/SC 3). Gating interface used in radiation therapy 1 Scope This standard specifies the technical requirements and test methods for gating interface used in radiation therapy. This standard is applicable to gating interface used in radiation therapy. Each manufacturer may provide other safety design and functional design schemes. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB 9706.5-2008 Medical electrical equipment — Part 2: Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV GB 9706.17-2009 Medical electrical equipment — Part 2: Particular requirements for the safety of gamma beam therapy equipment 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB 9706.5-2008 and GB 9706.17-2009 and the following apply. 3.1 beam hold condition in which a system is ready to quickly recover the beam on but has not been in the beam on state Note 1: Beam hold is different from the interrupt irradiation (equipment is shifted into beam off). Note 2: Beam hold, a sub-state of the irradiation state, is intended to quickly change into the expected irradiation therapy state. Note 3: It is usually used for gating, IMRT, etc. 3.2 beam off condition in which the radiation source(s) is fully shielded, and is also in a position in which it can be secured [Definition 2.101, GB 9706.17-2009]   3.3 beam termination/terminate irradiation signal to stop to start or immediately terminate irradiation from the Patient Position Monitoring System (PPMS) to the Treatment Delivery Device (TDD) Note: TDD described in this standard mainly includes medical electron accelerator, light ion therapy system, gamma beam stereotactic radiotherapy system, Co-60 remote machine and other equipment; PPMS mainly includes optical surface, X-ray transmission, abdominal pressure, magnetic field signal, ultrasound imaging, magnetic resonance imaging and other position monitoring systems. 3.4 gating interface gating interface is designed to enable TDD and PPMS to provide the following capabilities: a) Perform the beam hold or beam termination/terminate irradiation based on movement of the target area in the patient body or the position of the patient without operator's intervention. b) Turn off the beam in case of error or the patient state exceeding the deviation limit. Note: PPMS can change the beam generation state of TDD by two control ways. Both need to be implemented by hard wire between PPMS and TDD. The first way is beam gating connection, that is, beam hold, which allows PPMS to temporarily hold the beam without causing beam off. The second is gating interlock, which allows PPMS to require beam termination (i.e. "beam turn-off" described in GB 9706.5-2008) or prohibit beam on when an error is detected. 3.5 interlock setting preventing the start or the continued operation of equipment unless certain predetermined conditions prevail Note: It is a signal that enables the gating equipment to stop the beam. Please note that when the interlock occurs, the operator is required to take action to confirm it, and then resume treatment after it is cleared. [IEC/TR 60788: 2004] 3.6 interrupt irradiation interrupt irradiation signal sent by PPMS to TDD, which requires user's intervention to restart irradiation Note: There can only be one interface for interruption, and the TDD manufacturer should determine (and describe in random files) the impact of this interface. 3.7 fail-safe emergency response for minimizing the harm or mechanism to prevent an unsafe state in the event of a failure Example: Providing a redundant safety design.   4 Requirements and test methods 4.1 Electrical interface Details of the electrical signal specification and interface protocol specification for the gating interface shall be described in the TDD and PPMS random files, where applicable, and the verification function shall be included in the interface protocol. 4.2 Conditions for normal operation of beam termination function PPMS and TDD manufacturers shall ensure that the following functions (if provided) are normal: a) Gating interlock works normally. b) Dose interlock works normally. c) Beam termination works normally in using fail-safe and redundancy. 4.3 Delay time of beam hold and switch action The PPMS and TDD manufacturers shall have their respective system detection and action delay time provided in a random document: a) The TDD manufacturer shall provide the delay time from the receipt of the beam hold request to the beam hold state. b) The TDD manufacturer shall provide the delay time from the receipt of release beam hold request to the beam output state. c) The PPMS manufacturer shall provide the delay time from the availability of the beam hold condition to the issuance of the beam hold request. 4.4 Gating time The TDD manufacturer shall give the minimum limit of beam hold time and other limitations, and the PPMS manufacturer shall provide the corresponding configuration.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Requirements and test methods 4.1 Electrical interface 4.2 Conditions for normal operation of beam termination function 4.3 Delay time of beam hold and switch action 4.4 Gating time 4.5 Error handling and recovery 4.6 Basic operations and basic performance Bibliography
Referred in YY/T 1711-2020:
*GB 9706.5-2008 Medical electrical equipment - Part 2-1: Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV
*GB 9706.17-2009 Medical electrical equipment—Part 2:Particular requirements for the safety of gamma beam therapy equipment
*GB/T 95-2002 Plain washers - Product grade C
*GB/T 2664-2009 Mens suits and coats
*GB 4706.1-2005 Household and Similar Electrical Appliances – Safety - Part 1: General Requirements
*GB 17625.1-2022 Electromagnetic compatibility—Limits—Part 1: Limits for harmonic current emissions (equipment input current ≤ 16A per phase)
*GB/T 14048.5-2017 Low-voltage switchgear and controlgear-Part 5-1:Control circuit devices and switching element-Electromechanical control circuit devices
*GB 17625.1-2022 Electromagnetic compatibility—Limits—Part 1: Limits for harmonic current emissions (equipment input current ≤ 16A per phase)
*QB/T 1333-2018 Handbag and Knapsack
*GB 2762-2022 National Food Safety Standard - Maximum Levels of Contaminants in Foods
*GB/T 22849-2014 Knitted T-shirt
*GB 5749-2022 Standards for drinking water quality
*GB 14748-2006 Safety Requirements for Wheeled Child Conveyances
*GB/T 1591-2018 High strength low alloy structural steels
*GB 4943.1-2011 Information technology equipment -Safety - Part 1: General requirements
*GB 2763-2021 National Food Safety Standard-Maximum Residue Limits for Pesticides in Food
Code of China
Standard
YY/T 1711-2020  Gating interface used in radiation therapy (English Version)
Standard No.YY/T 1711-2020
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)165.0
Implemented on2022-6-1
Deliveryvia email in 1 business day
Detail of YY/T 1711-2020
Standard No.
YY/T 1711-2020
English Name
Gating interface used in radiation therapy
Chinese Name
放射治疗用门控接口
Chinese Classification
C43
Professional Classification
YY
ICS Classification
Issued by
National Medical Products Adminstration
Issued on
2020-06-30
Implemented on
2022-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
165.0
Keywords
YY/T 1711-2020, YY 1711-2020, YYT 1711-2020, YY/T1711-2020, YY/T 1711, YY/T1711, YY1711-2020, YY 1711, YY1711, YYT1711-2020, YYT 1711, YYT1711
Introduction of YY/T 1711-2020
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This standard was proposed by the National Medical Products Administration of the People’s Republic of China. This standard is under the jurisdiction of Subcommittee on Radiation Therapy, Nuclear Medicine and Radiodosimetry Equipment of National Technical Committee on Medical Electrical Equipment of Standardization Administration of China (SAC/TC 10/SC 3). Gating interface used in radiation therapy 1 Scope This standard specifies the technical requirements and test methods for gating interface used in radiation therapy. This standard is applicable to gating interface used in radiation therapy. Each manufacturer may provide other safety design and functional design schemes. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition (including any amendments) applies. GB 9706.5-2008 Medical electrical equipment — Part 2: Particular requirements for the safety of electron accelerators in the range 1 MeV to 50 MeV GB 9706.17-2009 Medical electrical equipment — Part 2: Particular requirements for the safety of gamma beam therapy equipment 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB 9706.5-2008 and GB 9706.17-2009 and the following apply. 3.1 beam hold condition in which a system is ready to quickly recover the beam on but has not been in the beam on state Note 1: Beam hold is different from the interrupt irradiation (equipment is shifted into beam off). Note 2: Beam hold, a sub-state of the irradiation state, is intended to quickly change into the expected irradiation therapy state. Note 3: It is usually used for gating, IMRT, etc. 3.2 beam off condition in which the radiation source(s) is fully shielded, and is also in a position in which it can be secured [Definition 2.101, GB 9706.17-2009]   3.3 beam termination/terminate irradiation signal to stop to start or immediately terminate irradiation from the Patient Position Monitoring System (PPMS) to the Treatment Delivery Device (TDD) Note: TDD described in this standard mainly includes medical electron accelerator, light ion therapy system, gamma beam stereotactic radiotherapy system, Co-60 remote machine and other equipment; PPMS mainly includes optical surface, X-ray transmission, abdominal pressure, magnetic field signal, ultrasound imaging, magnetic resonance imaging and other position monitoring systems. 3.4 gating interface gating interface is designed to enable TDD and PPMS to provide the following capabilities: a) Perform the beam hold or beam termination/terminate irradiation based on movement of the target area in the patient body or the position of the patient without operator's intervention. b) Turn off the beam in case of error or the patient state exceeding the deviation limit. Note: PPMS can change the beam generation state of TDD by two control ways. Both need to be implemented by hard wire between PPMS and TDD. The first way is beam gating connection, that is, beam hold, which allows PPMS to temporarily hold the beam without causing beam off. The second is gating interlock, which allows PPMS to require beam termination (i.e. "beam turn-off" described in GB 9706.5-2008) or prohibit beam on when an error is detected. 3.5 interlock setting preventing the start or the continued operation of equipment unless certain predetermined conditions prevail Note: It is a signal that enables the gating equipment to stop the beam. Please note that when the interlock occurs, the operator is required to take action to confirm it, and then resume treatment after it is cleared. [IEC/TR 60788: 2004] 3.6 interrupt irradiation interrupt irradiation signal sent by PPMS to TDD, which requires user's intervention to restart irradiation Note: There can only be one interface for interruption, and the TDD manufacturer should determine (and describe in random files) the impact of this interface. 3.7 fail-safe emergency response for minimizing the harm or mechanism to prevent an unsafe state in the event of a failure Example: Providing a redundant safety design.   4 Requirements and test methods 4.1 Electrical interface Details of the electrical signal specification and interface protocol specification for the gating interface shall be described in the TDD and PPMS random files, where applicable, and the verification function shall be included in the interface protocol. 4.2 Conditions for normal operation of beam termination function PPMS and TDD manufacturers shall ensure that the following functions (if provided) are normal: a) Gating interlock works normally. b) Dose interlock works normally. c) Beam termination works normally in using fail-safe and redundancy. 4.3 Delay time of beam hold and switch action The PPMS and TDD manufacturers shall have their respective system detection and action delay time provided in a random document: a) The TDD manufacturer shall provide the delay time from the receipt of the beam hold request to the beam hold state. b) The TDD manufacturer shall provide the delay time from the receipt of release beam hold request to the beam output state. c) The PPMS manufacturer shall provide the delay time from the availability of the beam hold condition to the issuance of the beam hold request. 4.4 Gating time The TDD manufacturer shall give the minimum limit of beam hold time and other limitations, and the PPMS manufacturer shall provide the corresponding configuration.
Contents of YY/T 1711-2020
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Requirements and test methods 4.1 Electrical interface 4.2 Conditions for normal operation of beam termination function 4.3 Delay time of beam hold and switch action 4.4 Gating time 4.5 Error handling and recovery 4.6 Basic operations and basic performance Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 1711-2020, YY 1711-2020, YYT 1711-2020, YY/T1711-2020, YY/T 1711, YY/T1711, YY1711-2020, YY 1711, YY1711, YYT1711-2020, YYT 1711, YYT1711