2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 4789.18-2024
GB 4789.18-2024   National food safety standard-Food microbiological examination-Sampling and sample treatment of milk and dairy products (English Version)
Standard No.: GB 4789.18-2024 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):90.0 remind me the price change

Email:

Implemented on:2024-8-8 Delivery: via email in 1~3 business day

→ → →

,,2024-8-8,0596A9D1BD2898311710313585642
Standard No.: GB 4789.18-2024
English Name: National food safety standard-Food microbiological examination-Sampling and sample treatment of milk and dairy products
Chinese Name: 食品安全国家标准食品 微生物学检验 乳与乳制品采样和检样处理
Chinese Classification: X09    Hygiene, safety and labor protection
Professional Classification: GB    National Standard
Source Content Issued by: NHC; SAMR
Issued on: 2024-2-8
Implemented on: 2024-8-8
Status: valid
Superseding:GB 4789.18-2010 Food microbiological examination: Milk and milk products
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 90.0
Delivery: via email in 1~3 business day
GB 4789.18-2024 National food safety standard Food microbiological examination - Sampling and sample processing of milk and dairy products 1 Scope This standard specifies the sampling and sample processing methods of milk and dairy products. This standard is applicable to the sampling and sample processing of milk and dairy products. 2 Equipment and materials 2.1 Sampling tools The sampling tools shall be made of stainless steel or other materials with appropriate strength, and they shall have smooth surfaces, and rounded corners, but not joints. The sampling tools shall be cleaned and sterilized and kept dry before use. Sampling tools include stirring appliances, sampling scoops and spoons, cutting wires, scissors, cutting tools (knives or spatulas), sampling drills, etc. 2.2 Sample containers The material (such as glass, stainless steel, and plastic) and structure of the sample containers shall be able to fully make the samples the original state. The containers and their lids shall be clean, sterile, and dry. The sample containers shall have sufficient volume to allow the samples to be thoroughly mixed prior to inspection. The sample containers also include sampling bags, sampling tubes, sampling bottles, and the like. 2.3 Other supplies They may include the alcohol lamp, thermometer, aluminum foil, sealing film, marker, and sampling registration form. 3 Sampling 3.1 Sampling principles and plans The sampling principles and plans shall be implemented in accordance with the requirements of GB 4789.1. The number (n) of the specimens to be sampled shall meet the requirements of relevant food safety standards. The sampling volume for each sample shall not be less than the volume of the sample for 5 × inspection units, or shall be determined according to the inspection purpose. The requirements for the sampling of food samples are specified as follows: 3.2 Fresh milk 3.2.1 The sample shall be mixed as thoroughly as possible, and sampling shall be done immediately after mixing. The sterile sampling tool shall be used to collect samples from the same batch (specifically referring to individual milk storage tanks or milk tankers). 3.2.2 For milk storage devices with partitioned areas, a proportionate amount of well-mixed representative samples shall be collected from each partitioned area based on the different quantities of milk stored in each area. Sampling after mixing is not allowed. 3.3 Liquid dairy products (pasteurized milk, high-temperature sterilized milk, modified milk, etc.) 3.3.1 Individually packaged liquid dairy products of less than or equal to 1,000g (mL): individually packaged liquid dairy products from the same batch shall be sampled. 3.3.2 Individually packaged liquid dairy products of more than 1,000g (mL): individually packaged liquid dairy products from the same batch shall be sampled; or sampling shall be conducted after shaking and mixing evenly. 3.4 Semi-solid dairy products 3.4.1 Concentrated dairy products, fermented milk, and flavored fermented milk 3.4.1.1 Individually packaged products of less than or equal to 1,000g (mL): individually packaged products from the same batch shall be sampled. 3.4.1.2 Individually packaged products of more than 1,000g (mL): the sample shall be shaken or stirred with an agitator before sampling to achieve uniformity, and then sampled. If the sample cannot be mixed uniformly, representative samples shall be taken from different parts of the sample container. 3.4.2 Single cream, cream, and anhydrous cream 3.4.2.1 Individually packaged products of less than or equal to 1,000g (mL): individually packaged products from the same batch shall be sampled. 3.4.2.2 Individually packaged products of more than 1,000g (mL): the sample shall be shaken or stirred with an agitator before sampling to achieve uniformity, and then sampled. For solid cream and its products, a sterile spatula shall be used to remove the surface product, with a thickness of not less than 5 mm. The clean and dry sampling drill shall be inserted downwards along the cutting direction of the packaging container, at a constant speed, into the bottom. When the sampling drill reaches the bottom of the container, the sampling drill shall be rotated 180° and then withdrawn, and the collected sample shall be transferred into the sample container. 3.5 Solid dairy products (cheese, processed cheese, cheese products, milk powder, modified milk powder, whey powder and whey protein powder, casein and caseinates, etc.) 3.5.1 Individually packaged products of less than or equal to 1,000g: individually packaged products from the same batch shall be sampled. 3.5.2 For individually packaged cheese, processed cheese, and cheese products weighing more than 1000g, the following methods of sampling may be used based on the shape and type of the product: (1) At a distance of not less than 10 cm from the edge, insert the sampler diagonally towards the center of the product to a flat surface, and take one or more samples; or (2) insert the sampler perpendicularly into one side and through the center of the product to the opposite side for sampling; or (3) insert the sampler horizontally between two planes into the vertical surface of the product, directing it towards the center for sampling; or (4) if the product is packaged in barrels, boxes, or other large containers, or if the product is formed into compacted large blocks, insert the sampler diagonally from the top of the container to the bottom for sampling. 3.5.3 For individually packaged products such as milk powder, modified milk powder, whey powder and whey protein powder, casein and caseinates, etc., weighing more than 1,000g, the sterile and dry sampling drill shall be inserted at a constant speed along the cutting direction of the packaging container with the face down. When the sampling drill reaches the bottom of the container, the sampling drill shall be withdrawn and the collected sample shall be transferred into the sample container. 3.6 Sample storage and transportation The requirements of GB 4789.1 shall apply. 4 Preparation of samples 4.1 Opening of packages The sterile sampling container in which the sample is packaged or placed shall be opened aseptically. Products packaged in plastic or paper boxes (bags): sterilize the box lid or bag mouth with 75% alcohol cotton ball, and cut it open with aseptic scissors; products packaged in bottles (barrels): sterilize the package with 75% alcohol cotton ball or flame, remove the bottle (barrel) cap aseptically, and sterilize the bottle (barrel) mouth by flame.
Contents Foreword i 1 Scope 2 Equipment and materials 3 Sampling 4 Preparation of samples 5 Inspection
Code of China
Standard
GB 4789.18-2024  National food safety standard-Food microbiological examination-Sampling and sample treatment of milk and dairy products (English Version)
Standard No.GB 4789.18-2024
Statusvalid
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)90.0
Implemented on2024-8-8
Deliveryvia email in 1~3 business day
Detail of GB 4789.18-2024
Standard No.
GB 4789.18-2024
English Name
National food safety standard-Food microbiological examination-Sampling and sample treatment of milk and dairy products
Chinese Name
食品安全国家标准食品 微生物学检验 乳与乳制品采样和检样处理
Chinese Classification
X09
Professional Classification
GB
ICS Classification
Issued by
NHC; SAMR
Issued on
2024-2-8
Implemented on
2024-8-8
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 4789.18-2010 Food microbiological examination: Milk and milk products
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
90.0
Keywords
GB 4789.18-2024, GB/T 4789.18-2024, GBT 4789.18-2024, GB4789.18-2024, GB 4789.18, GB4789.18, GB/T4789.18-2024, GB/T 4789.18, GB/T4789.18, GBT4789.18-2024, GBT 4789.18, GBT4789.18
Introduction of GB 4789.18-2024
GB 4789.18-2024 National food safety standard Food microbiological examination - Sampling and sample processing of milk and dairy products 1 Scope This standard specifies the sampling and sample processing methods of milk and dairy products. This standard is applicable to the sampling and sample processing of milk and dairy products. 2 Equipment and materials 2.1 Sampling tools The sampling tools shall be made of stainless steel or other materials with appropriate strength, and they shall have smooth surfaces, and rounded corners, but not joints. The sampling tools shall be cleaned and sterilized and kept dry before use. Sampling tools include stirring appliances, sampling scoops and spoons, cutting wires, scissors, cutting tools (knives or spatulas), sampling drills, etc. 2.2 Sample containers The material (such as glass, stainless steel, and plastic) and structure of the sample containers shall be able to fully make the samples the original state. The containers and their lids shall be clean, sterile, and dry. The sample containers shall have sufficient volume to allow the samples to be thoroughly mixed prior to inspection. The sample containers also include sampling bags, sampling tubes, sampling bottles, and the like. 2.3 Other supplies They may include the alcohol lamp, thermometer, aluminum foil, sealing film, marker, and sampling registration form. 3 Sampling 3.1 Sampling principles and plans The sampling principles and plans shall be implemented in accordance with the requirements of GB 4789.1. The number (n) of the specimens to be sampled shall meet the requirements of relevant food safety standards. The sampling volume for each sample shall not be less than the volume of the sample for 5 × inspection units, or shall be determined according to the inspection purpose. The requirements for the sampling of food samples are specified as follows: 3.2 Fresh milk 3.2.1 The sample shall be mixed as thoroughly as possible, and sampling shall be done immediately after mixing. The sterile sampling tool shall be used to collect samples from the same batch (specifically referring to individual milk storage tanks or milk tankers). 3.2.2 For milk storage devices with partitioned areas, a proportionate amount of well-mixed representative samples shall be collected from each partitioned area based on the different quantities of milk stored in each area. Sampling after mixing is not allowed. 3.3 Liquid dairy products (pasteurized milk, high-temperature sterilized milk, modified milk, etc.) 3.3.1 Individually packaged liquid dairy products of less than or equal to 1,000g (mL): individually packaged liquid dairy products from the same batch shall be sampled. 3.3.2 Individually packaged liquid dairy products of more than 1,000g (mL): individually packaged liquid dairy products from the same batch shall be sampled; or sampling shall be conducted after shaking and mixing evenly. 3.4 Semi-solid dairy products 3.4.1 Concentrated dairy products, fermented milk, and flavored fermented milk 3.4.1.1 Individually packaged products of less than or equal to 1,000g (mL): individually packaged products from the same batch shall be sampled. 3.4.1.2 Individually packaged products of more than 1,000g (mL): the sample shall be shaken or stirred with an agitator before sampling to achieve uniformity, and then sampled. If the sample cannot be mixed uniformly, representative samples shall be taken from different parts of the sample container. 3.4.2 Single cream, cream, and anhydrous cream 3.4.2.1 Individually packaged products of less than or equal to 1,000g (mL): individually packaged products from the same batch shall be sampled. 3.4.2.2 Individually packaged products of more than 1,000g (mL): the sample shall be shaken or stirred with an agitator before sampling to achieve uniformity, and then sampled. For solid cream and its products, a sterile spatula shall be used to remove the surface product, with a thickness of not less than 5 mm. The clean and dry sampling drill shall be inserted downwards along the cutting direction of the packaging container, at a constant speed, into the bottom. When the sampling drill reaches the bottom of the container, the sampling drill shall be rotated 180° and then withdrawn, and the collected sample shall be transferred into the sample container. 3.5 Solid dairy products (cheese, processed cheese, cheese products, milk powder, modified milk powder, whey powder and whey protein powder, casein and caseinates, etc.) 3.5.1 Individually packaged products of less than or equal to 1,000g: individually packaged products from the same batch shall be sampled. 3.5.2 For individually packaged cheese, processed cheese, and cheese products weighing more than 1000g, the following methods of sampling may be used based on the shape and type of the product: (1) At a distance of not less than 10 cm from the edge, insert the sampler diagonally towards the center of the product to a flat surface, and take one or more samples; or (2) insert the sampler perpendicularly into one side and through the center of the product to the opposite side for sampling; or (3) insert the sampler horizontally between two planes into the vertical surface of the product, directing it towards the center for sampling; or (4) if the product is packaged in barrels, boxes, or other large containers, or if the product is formed into compacted large blocks, insert the sampler diagonally from the top of the container to the bottom for sampling. 3.5.3 For individually packaged products such as milk powder, modified milk powder, whey powder and whey protein powder, casein and caseinates, etc., weighing more than 1,000g, the sterile and dry sampling drill shall be inserted at a constant speed along the cutting direction of the packaging container with the face down. When the sampling drill reaches the bottom of the container, the sampling drill shall be withdrawn and the collected sample shall be transferred into the sample container. 3.6 Sample storage and transportation The requirements of GB 4789.1 shall apply. 4 Preparation of samples 4.1 Opening of packages The sterile sampling container in which the sample is packaged or placed shall be opened aseptically. Products packaged in plastic or paper boxes (bags): sterilize the box lid or bag mouth with 75% alcohol cotton ball, and cut it open with aseptic scissors; products packaged in bottles (barrels): sterilize the package with 75% alcohol cotton ball or flame, remove the bottle (barrel) cap aseptically, and sterilize the bottle (barrel) mouth by flame.
Contents of GB 4789.18-2024
Contents Foreword i 1 Scope 2 Equipment and materials 3 Sampling 4 Preparation of samples 5 Inspection
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 4789.18-2024, GB/T 4789.18-2024, GBT 4789.18-2024, GB4789.18-2024, GB 4789.18, GB4789.18, GB/T4789.18-2024, GB/T 4789.18, GB/T4789.18, GBT4789.18-2024, GBT 4789.18, GBT4789.18