2025-12-15 216.73.216.89
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5009.205-2013
GB 5009.205-2013   National Food Safety Standard-TEQ Determination of dioxin and its analogues (English Version)
Standard No.: GB 5009.205-2013 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 19000 words Translation Price(USD):470.0 remind me the price change

Email:

Implemented on:2014-6-1 Delivery: via email in 1 business day

→ → →

,2024-8-8,2014-6-1,14113818301896CC133C1254A255B
Standard No.: GB 5009.205-2013
English Name: National Food Safety Standard-TEQ Determination of dioxin and its analogues
Chinese Name: 食品安全国家标准 食品中二噁英及其类似物毒性当量的测定
Chinese Classification: X09    Hygiene, safety and labor protection
Professional Classification: GB    National Standard
Source Content Issued by: Health and Family Planning Commission
Issued on: 2013-11-29
Implemented on: 2014-6-1
Status: superseded
Superseded by:GB 5009.205-2024 National food safety standard-Determination of toxic equivalent of dioxins and their analogues in food
Superseded on:2024-8-8
Superseding:GB/T 5009.205-2007 Determination of toxic equivalencies of dioxin and dioxin-like compounds in foods
Target Language: English
File Format: PDF
Word Count: 19000 words
Translation Price(USD): 470.0
Delivery: via email in 1 business day
1. Scope This standard specifies the determination methods of contents and toxic equivalent quantities (TEQ) of 17 species of 2, 3, 7, 8-substituted polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and 12 species of dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) in foods. This standard is applicable to determine the content and TEQ of 17 species of 2, 3, 7, 8-substituted polychlorinated dibenzodioxins, polychlorinated dibenzofurans (PCDD/Fs) and 12 species of DL-PCBs specified in Table A.1 in Appendix A. 2. Principle Monitor two ions of the target compound through accurately mass measurement with high-resolution gas chromatography-mass spectrometry, under resolution rate of mass spectrum greater than 10,000; obtain the specific response of target compound; exactly determine the content of 2, 3, 7, 8 chlorine substituted PCDD/Fs and DL-PCBs in foods with the isotope labeled compound of target compound as quantitative internal standard through stable isotope dilution; multiply the toxic equivalency factor (TEF)of each target compound with the measured content, accumulate the results, and then obtain the toxic equivalent quantity (TEQ) of the dioxin and dioxin-like compounds in the sample. 3. Reagents and Materials 3.1 Organic solvents Note: the following organic solvents are pesticide residues, in which, dioxin and dioxin-like compounds shall not be detected after being concentrated by 10,000 times. 3.1.1 Acetone (C3H6O). 3.1.2 N-hexane (C6H14). 3.1.3 Toluene (C7H8). 3.1.4 Cyclohexane (C6H12). 3.1.5 Dichloromethane (CH2Cl2). 3.1.6 Ethyl ether (C4H10O). 3.1.7 Methanol (CH3OH). 3.1.8 N-nonane (C9H20). 3.1.9 Isooctane (C8H18). 3.1.10 Ethyl acetate (CH3COOCH2CH3). 3.1.11 Ethanol (CH3CH2OH). 3.2 Standard solutions 3.2.1 PCDD/Fs standard solution Note: standard solution specified in EPA 1613-1997 is recommended in this standard, and equivalent standard product may be selected for each laboratory according to specific conditions. The preparation of stock solution, where required, shall be carried out in ventilating cabinet; gas mask shall be provided. 3.2.1.1 Standard solution (CS3WT solution) for calibration and time window determination: solution prepared with nonane and containing natural and isotope labeled PCDD/Fs (quantitative internal standard, purification standard and internal recovery standard); it is used for calibration and corroboration of method, determination of DB5MS capillary column (or equivalent column) time window, and inspection for separation degree of 2, 3, 7, 8-TCDD (see Table B.1 in Appendix B). 3.2.1.2 Standard purification solution: 37C14-2, 3, 7, 8-TCDD solution (with concentration of 40±2μg/L) prepared with nonane.
Foreword I 1. Scope 2. Principle 3. Reagents and Materials 4. Instruments and Equipment 5. Sample Preparation and Purification 6. PCDD/Fs Chromaticness Analysis 7. DL-PCBs Chromaticness Analysis 8. Expression of Analysis Result 9. Quality Assurance and Quality Control 10. Others Appendix A Toxic Equivalency Factors of Polychlorinated Dibenzodioxins (PCDDs), Furans and Dioxin-like Polychlorinated Biphenyls (DL-PCBs) Appendix B Standard Solutions Appendix C Technical Requirements of Measurement Method Appendix D Soxhlet Extractor and Analysis Process Figure Appendix E Precision
Code of China
Standard
GB 5009.205-2013  National Food Safety Standard-TEQ Determination of dioxin and its analogues (English Version)
Standard No.GB 5009.205-2013
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count19000 words
Price(USD)470.0
Implemented on2014-6-1
Deliveryvia email in 1 business day
Detail of GB 5009.205-2013
Standard No.
GB 5009.205-2013
English Name
National Food Safety Standard-TEQ Determination of dioxin and its analogues
Chinese Name
食品安全国家标准 食品中二噁英及其类似物毒性当量的测定
Chinese Classification
X09
Professional Classification
GB
ICS Classification
Issued by
Health and Family Planning Commission
Issued on
2013-11-29
Implemented on
2014-6-1
Status
superseded
Superseded by
GB 5009.205-2024 National food safety standard-Determination of toxic equivalent of dioxins and their analogues in food
Superseded on
2024-8-8
Abolished on
Superseding
GB/T 5009.205-2007 Determination of toxic equivalencies of dioxin and dioxin-like compounds in foods
Language
English
File Format
PDF
Word Count
19000 words
Price(USD)
470.0
Keywords
GB 5009.205-2013, GB/T 5009.205-2013, GBT 5009.205-2013, GB5009.205-2013, GB 5009.205, GB5009.205, GB/T5009.205-2013, GB/T 5009.205, GB/T5009.205, GBT5009.205-2013, GBT 5009.205, GBT5009.205
Introduction of GB 5009.205-2013
1. Scope This standard specifies the determination methods of contents and toxic equivalent quantities (TEQ) of 17 species of 2, 3, 7, 8-substituted polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and 12 species of dioxins and dioxin-like polychlorinated biphenyls (DL-PCBs) in foods. This standard is applicable to determine the content and TEQ of 17 species of 2, 3, 7, 8-substituted polychlorinated dibenzodioxins, polychlorinated dibenzofurans (PCDD/Fs) and 12 species of DL-PCBs specified in Table A.1 in Appendix A. 2. Principle Monitor two ions of the target compound through accurately mass measurement with high-resolution gas chromatography-mass spectrometry, under resolution rate of mass spectrum greater than 10,000; obtain the specific response of target compound; exactly determine the content of 2, 3, 7, 8 chlorine substituted PCDD/Fs and DL-PCBs in foods with the isotope labeled compound of target compound as quantitative internal standard through stable isotope dilution; multiply the toxic equivalency factor (TEF)of each target compound with the measured content, accumulate the results, and then obtain the toxic equivalent quantity (TEQ) of the dioxin and dioxin-like compounds in the sample. 3. Reagents and Materials 3.1 Organic solvents Note: the following organic solvents are pesticide residues, in which, dioxin and dioxin-like compounds shall not be detected after being concentrated by 10,000 times. 3.1.1 Acetone (C3H6O). 3.1.2 N-hexane (C6H14). 3.1.3 Toluene (C7H8). 3.1.4 Cyclohexane (C6H12). 3.1.5 Dichloromethane (CH2Cl2). 3.1.6 Ethyl ether (C4H10O). 3.1.7 Methanol (CH3OH). 3.1.8 N-nonane (C9H20). 3.1.9 Isooctane (C8H18). 3.1.10 Ethyl acetate (CH3COOCH2CH3). 3.1.11 Ethanol (CH3CH2OH). 3.2 Standard solutions 3.2.1 PCDD/Fs standard solution Note: standard solution specified in EPA 1613-1997 is recommended in this standard, and equivalent standard product may be selected for each laboratory according to specific conditions. The preparation of stock solution, where required, shall be carried out in ventilating cabinet; gas mask shall be provided. 3.2.1.1 Standard solution (CS3WT solution) for calibration and time window determination: solution prepared with nonane and containing natural and isotope labeled PCDD/Fs (quantitative internal standard, purification standard and internal recovery standard); it is used for calibration and corroboration of method, determination of DB5MS capillary column (or equivalent column) time window, and inspection for separation degree of 2, 3, 7, 8-TCDD (see Table B.1 in Appendix B). 3.2.1.2 Standard purification solution: 37C14-2, 3, 7, 8-TCDD solution (with concentration of 40±2μg/L) prepared with nonane.
Contents of GB 5009.205-2013
Foreword I 1. Scope 2. Principle 3. Reagents and Materials 4. Instruments and Equipment 5. Sample Preparation and Purification 6. PCDD/Fs Chromaticness Analysis 7. DL-PCBs Chromaticness Analysis 8. Expression of Analysis Result 9. Quality Assurance and Quality Control 10. Others Appendix A Toxic Equivalency Factors of Polychlorinated Dibenzodioxins (PCDDs), Furans and Dioxin-like Polychlorinated Biphenyls (DL-PCBs) Appendix B Standard Solutions Appendix C Technical Requirements of Measurement Method Appendix D Soxhlet Extractor and Analysis Process Figure Appendix E Precision
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5009.205-2013, GB/T 5009.205-2013, GBT 5009.205-2013, GB5009.205-2013, GB 5009.205, GB5009.205, GB/T5009.205-2013, GB/T 5009.205, GB/T5009.205, GBT5009.205-2013, GBT 5009.205, GBT5009.205