2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5413.37-2010
GB 5413.37-2010   National food safety standard Determination of aflatoxin M1 in milk and milk products (English Version)
Standard No.: GB 5413.37-2010 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8000 words Translation Price(USD):200.0 remind me the price change

Email:

Implemented on:2010-6-1 Delivery: via email in 1 business day

→ → →

,2017-6-2,2010-6-1,14113818189422FC29FFFA12A9ADD
Standard No.: GB 5413.37-2010
English Name: National food safety standard Determination of aflatoxin M1 in milk and milk products
Chinese Name: 食品安全国家标准 乳和乳制品中黄曲霉毒素M1的测定
Chinese Classification: X09    Hygiene, safety and labor protection
Professional Classification: GB    National Standard
Source Content Issued by: MOH
Issued on: 2010-3-26
Implemented on: 2010-6-1
Status: superseded
Superseded by:GB 5009.24-2016 National Food Safety Standard — Determination of M Aflatoxins in Foods
Superseded on:2017-6-2
Superseding:GB/T 18980-2003 Determination of aflatoxin M1 content in milk and milk powder-Cleanup by immunoaffinity chromatogaphy and determination by high-performance liquid chromatigraphy and fluorometer
Target Language: English
File Format: PDF
Word Count: 8000 words
Translation Price(USD): 200.0
Delivery: via email in 1 business day
1 Scope This standard specifies the method for determination of aflatoxin M1 in milk and milk products. Method I in this standard is applicable to the determination of aflatoxin M1 in milk and milk products; Method II is applicable to the determination of aflatoxin M1 in milk, milk powder and low fat milk, skimmed milk, low fat milk powder and skimmed milk powder; Method III is applicable to the determination of aflatoxin M1 in milk and milk powder; Method IV is applicable to the determination of aflatoxin M1 in liquid milk and milk powder. 2 Normative References The documents referenced in this standard are indispensable for the application of this standard. For dated references, only the dated edition of the document is applicable to this standard. For undated references, the latest edition (including all amendments) of the document is applicable to this standard. Method I Clean-up by Immunoaffinity Chromatography and Determination by Liquid Chromatography-Tandem Mass Spectrometry 3 Principle The sample liquid or solid-sample extracting liquid shall pass through homogeneity, ultrasonic extracting and centrifugation; then the obtained supernatant shall be purified through the immunoaffinity column; then the eluent shall be dried with nitrogen gas and subsequently be volumetrically scaled to be filtered via the microporous filtering film, separated with liquid chromatography, and ionized via electrospray ionization (ESI), and finally be tested with multiple reaction monitoring (MRM) approach. The matrix shall be quantified via standard addition method and external standard method. 4 Reagents and Materials Unless otherwise specified, reagents used in this method are all analytically pure, and water is the Grade 1 water as specified in GB/T 6682. 4.1 Formic acid (HCOOH). 4.2 Acetonitrile (CH3CN): chromatographically pure. 4.3 Petroleum ether (CnH2n+2): boiling range is 30℃~60℃. 4.4 Trichloromethane (CHCl3). 4.5 Nitrogen: purity ≥99.9%. 4.6 Aflatoxin M1 standard sample: purity ≥98%. 4.7 Acetonitrile-water solution(1+4): add 100mL acetonitrile into 400mL water. 4.8 Acetonitrile-water solution(1+9): add 50mL acetonitrile into 450mL water. 4.9 0.1% formic acid water solution: pipet 1mL formic acid (4.1) and dilute with water to 1,000mL. 4.10 Acetonitrile-methanol solution(50+50): add 500mL methanol into 500mL acetonitrile. 4.11 Sodium hydroxide solution (0.5mol/L): weigh 2g sodium hydroxide and dissolve it into 100mL water. 4.12 Blank matrix solution Weigh 8 negative samples respectively that have the same matrix with the to-be-tested sample and are free of aflatoxin into the 100mL beaker. Conduct the following operations according to the test solutions extraction (6.1) and purification procedure (6.2). Combine the eight pieces of purification liquid and filter with disposable filtration head (5.23) of 0.22μm microporous filtering film. Discard the first 0.5mL filter liquor and take a small amount of filter liquor for the test of liquid chromatographmass spectrometer. After obtaining the chromatograph-mass spectrogram, contrast with the diagram A.2 of the Appendix A, the corresponding retention time position shall be free of aflatoxin M1. Transfer the residual filter liquor into the brown bottle and preserve it in th refrigerator at -20℃ for the preparation of standard series solution. 4.13 The stock standard solution of aflatoxin M1: weigh 0.10mg (to the accuracy of 0.01mg) standard aflatoxin M1 respectively, dissolve with trichloromethane (4.4) and volumetrically scale to 10mL. The concentration of this standard solution is 0.01mg/mL. Transfer the solution into a brown bottle and preserve it in the refrigerator at -20℃ for standby. 4.14 Standard series solution of aflatoxin M1: pipet 10μL aflatoxin M1 stock standard solution (4.13) into 10mL volumetric flask and blow the trichloromethane with nitrogen gas until it is closely dry. Volumetrically scale the blank matrix solution (4.12) to scale and obtain the M1 standard intermediate of 10ng concentration. And then, use the blank matrix solution (4.12) to dilute the aflatoxin M1 standard intermediate to such series standard working solutions of 0.5ng/mL, 0.8ng/mL, 1.0ng/mL, 2.0ng/mL, 4.0ng/mL, 6.0ng/mL, and 8.0ng/mL.
Foreword I 1 Scope 2 Normative References Method I Clean-up by Immunoaffinity Chromatography and Determination by Liquid Chromatography-Tandem Mass Spectrometry 3 Principle 4 Reagents and Materials 5 Apparatus and Equipments 6 Analytical Procedures 7 Expression of Analytical Results 8 Precision Method II Clean-up by Immunoaffinity Chromatography and Determination by High-performance Liquid Chromatography 9 Principle 10 Reagents and Materials 11 Apparatus and Equipments 12 Analytical Procedures 13 Expression of Analysis Results 14 Precision Method III Clean-up by Immunoaffinity Chromatography, Fluorescence Spectrophotometry 15 Principle 16 Reagents and Materials 17 Apparatus and Equipments 18 Analytical Procedures 19 Expression of Analytical Result Method IV Double Flow Enzyme-linked Immunosorbent Assay 20 Principle 21 Reagents and Materials 22 Apparatus and Equipments 23 Analytical Procedures 24 Expression of Analysis Results 25 Other Appendix A (Informative) Chromatogram and Reference Condition for Aflatoxin M1 - Clean-up by Immunoaffinity Chromatography and Determination by Liquid Chromatography-Tandem Mass Spectrometry Appendix B (Informative) Test Results from Many Different Laboratories
Code of China
Standard
GB 5413.37-2010  National food safety standard Determination of aflatoxin M1 in milk and milk products (English Version)
Standard No.GB 5413.37-2010
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count8000 words
Price(USD)200.0
Implemented on2010-6-1
Deliveryvia email in 1 business day
Detail of GB 5413.37-2010
Standard No.
GB 5413.37-2010
English Name
National food safety standard Determination of aflatoxin M1 in milk and milk products
Chinese Name
食品安全国家标准 乳和乳制品中黄曲霉毒素M1的测定
Chinese Classification
X09
Professional Classification
GB
ICS Classification
Issued by
MOH
Issued on
2010-3-26
Implemented on
2010-6-1
Status
superseded
Superseded by
GB 5009.24-2016 National Food Safety Standard — Determination of M Aflatoxins in Foods
Superseded on
2017-6-2
Abolished on
Superseding
GB/T 18980-2003 Determination of aflatoxin M1 content in milk and milk powder-Cleanup by immunoaffinity chromatogaphy and determination by high-performance liquid chromatigraphy and fluorometer
Language
English
File Format
PDF
Word Count
8000 words
Price(USD)
200.0
Keywords
GB 5413.37-2010, GB/T 5413.37-2010, GBT 5413.37-2010, GB5413.37-2010, GB 5413.37, GB5413.37, GB/T5413.37-2010, GB/T 5413.37, GB/T5413.37, GBT5413.37-2010, GBT 5413.37, GBT5413.37
Introduction of GB 5413.37-2010
1 Scope This standard specifies the method for determination of aflatoxin M1 in milk and milk products. Method I in this standard is applicable to the determination of aflatoxin M1 in milk and milk products; Method II is applicable to the determination of aflatoxin M1 in milk, milk powder and low fat milk, skimmed milk, low fat milk powder and skimmed milk powder; Method III is applicable to the determination of aflatoxin M1 in milk and milk powder; Method IV is applicable to the determination of aflatoxin M1 in liquid milk and milk powder. 2 Normative References The documents referenced in this standard are indispensable for the application of this standard. For dated references, only the dated edition of the document is applicable to this standard. For undated references, the latest edition (including all amendments) of the document is applicable to this standard. Method I Clean-up by Immunoaffinity Chromatography and Determination by Liquid Chromatography-Tandem Mass Spectrometry 3 Principle The sample liquid or solid-sample extracting liquid shall pass through homogeneity, ultrasonic extracting and centrifugation; then the obtained supernatant shall be purified through the immunoaffinity column; then the eluent shall be dried with nitrogen gas and subsequently be volumetrically scaled to be filtered via the microporous filtering film, separated with liquid chromatography, and ionized via electrospray ionization (ESI), and finally be tested with multiple reaction monitoring (MRM) approach. The matrix shall be quantified via standard addition method and external standard method. 4 Reagents and Materials Unless otherwise specified, reagents used in this method are all analytically pure, and water is the Grade 1 water as specified in GB/T 6682. 4.1 Formic acid (HCOOH). 4.2 Acetonitrile (CH3CN): chromatographically pure. 4.3 Petroleum ether (CnH2n+2): boiling range is 30℃~60℃. 4.4 Trichloromethane (CHCl3). 4.5 Nitrogen: purity ≥99.9%. 4.6 Aflatoxin M1 standard sample: purity ≥98%. 4.7 Acetonitrile-water solution(1+4): add 100mL acetonitrile into 400mL water. 4.8 Acetonitrile-water solution(1+9): add 50mL acetonitrile into 450mL water. 4.9 0.1% formic acid water solution: pipet 1mL formic acid (4.1) and dilute with water to 1,000mL. 4.10 Acetonitrile-methanol solution(50+50): add 500mL methanol into 500mL acetonitrile. 4.11 Sodium hydroxide solution (0.5mol/L): weigh 2g sodium hydroxide and dissolve it into 100mL water. 4.12 Blank matrix solution Weigh 8 negative samples respectively that have the same matrix with the to-be-tested sample and are free of aflatoxin into the 100mL beaker. Conduct the following operations according to the test solutions extraction (6.1) and purification procedure (6.2). Combine the eight pieces of purification liquid and filter with disposable filtration head (5.23) of 0.22μm microporous filtering film. Discard the first 0.5mL filter liquor and take a small amount of filter liquor for the test of liquid chromatographmass spectrometer. After obtaining the chromatograph-mass spectrogram, contrast with the diagram A.2 of the Appendix A, the corresponding retention time position shall be free of aflatoxin M1. Transfer the residual filter liquor into the brown bottle and preserve it in th refrigerator at -20℃ for the preparation of standard series solution. 4.13 The stock standard solution of aflatoxin M1: weigh 0.10mg (to the accuracy of 0.01mg) standard aflatoxin M1 respectively, dissolve with trichloromethane (4.4) and volumetrically scale to 10mL. The concentration of this standard solution is 0.01mg/mL. Transfer the solution into a brown bottle and preserve it in the refrigerator at -20℃ for standby. 4.14 Standard series solution of aflatoxin M1: pipet 10μL aflatoxin M1 stock standard solution (4.13) into 10mL volumetric flask and blow the trichloromethane with nitrogen gas until it is closely dry. Volumetrically scale the blank matrix solution (4.12) to scale and obtain the M1 standard intermediate of 10ng concentration. And then, use the blank matrix solution (4.12) to dilute the aflatoxin M1 standard intermediate to such series standard working solutions of 0.5ng/mL, 0.8ng/mL, 1.0ng/mL, 2.0ng/mL, 4.0ng/mL, 6.0ng/mL, and 8.0ng/mL.
Contents of GB 5413.37-2010
Foreword I 1 Scope 2 Normative References Method I Clean-up by Immunoaffinity Chromatography and Determination by Liquid Chromatography-Tandem Mass Spectrometry 3 Principle 4 Reagents and Materials 5 Apparatus and Equipments 6 Analytical Procedures 7 Expression of Analytical Results 8 Precision Method II Clean-up by Immunoaffinity Chromatography and Determination by High-performance Liquid Chromatography 9 Principle 10 Reagents and Materials 11 Apparatus and Equipments 12 Analytical Procedures 13 Expression of Analysis Results 14 Precision Method III Clean-up by Immunoaffinity Chromatography, Fluorescence Spectrophotometry 15 Principle 16 Reagents and Materials 17 Apparatus and Equipments 18 Analytical Procedures 19 Expression of Analytical Result Method IV Double Flow Enzyme-linked Immunosorbent Assay 20 Principle 21 Reagents and Materials 22 Apparatus and Equipments 23 Analytical Procedures 24 Expression of Analysis Results 25 Other Appendix A (Informative) Chromatogram and Reference Condition for Aflatoxin M1 - Clean-up by Immunoaffinity Chromatography and Determination by Liquid Chromatography-Tandem Mass Spectrometry Appendix B (Informative) Test Results from Many Different Laboratories
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5413.37-2010, GB/T 5413.37-2010, GBT 5413.37-2010, GB5413.37-2010, GB 5413.37, GB5413.37, GB/T5413.37-2010, GB/T 5413.37, GB/T5413.37, GBT5413.37-2010, GBT 5413.37, GBT5413.37