Position: Chinese Standard in English/GB/T 21707-2025
GB/T 21707-2025   Insulation specification for frequency conversion machine (English Version)
Standard No.: GB/T 21707-2025 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 17000 words Translation Price(USD):510.0 remind me the price change

Email:

Implemented on:2025-12-1 Delivery: via email in 1~3 business day

→ → →

,,2025-12-1,9F0C410D6A6D34A31749469384714
Standard No.: GB/T 21707-2025
English Name: Insulation specification for frequency conversion machine
Chinese Name: 变频调速电机绝缘规范
Chinese Classification: K20    Electric rotating machinery in general
Professional Classification: GB    National Standard
ICS Classification: 29.160.01 29.160.01    Rotating machinery in general 29.160.01
Source Content Issued by: SAMR; SAC
Issued on: 2025-05-30
Implemented on: 2025-12-1
Status: valid
Superseding:GB/T 21707-2018 Insulation specification for variable frequency adjustable speed definite purpose converter-fed three-phase induction motors
Target Language: English
File Format: PDF
Word Count: 17000 words
Translation Price(USD): 510.0
Delivery: via email in 1~3 business day
GB/T 21707-2025 Insulation specification for frequency conversion machine 1 Scope This document specifies the technical requirements, test methods, test equipment, and inspection rules for the insulation of frequency conversion machine. This document is applicable to frequency conversion machine with a rated voltage of 1,140V or below. It may serve as a reference for high-voltage frequency conversion motors with rated voltages above 1,140 V. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 4074.7-2024 Test methods of winding wires - Part 7: Test procedure for the determination of the temperature index of enamelled winding wires GB/T 5591.3-2018 Combined flexible materials for electrical insulation - Part 3: Specifications for individual materials GB/T 6109.1 Enamelled round winding wire - Part 1: General requirements GB/T 7095.1 Enamelled rectangular copper winding wires - Part 1: General requirements GB/T 11026.4-2012 Electrical insulating materials - Thermal endurance properties - Part 4: Ageing ovens - Single-chamber ovens GB/T 17948.1-2018 Rotating electrical machines - Functional evaluation of insulation systems - Test procedures for wire-wound windings - Thermal evaluation and classification GB/T 17948.3-2017 Rotating electrical machines - Functional evaluation of insulation systems - Test procedures for form-wound windings - Thermal evaluation and classification of insulation systems used in rotating machines GB/T 20629.3-2019 Non-cellulosic papers for electrical purposes - Part 3: Unfilled aramid (aromatic polyamide) papers GB/T 22720.1-2017 Rotating electrical machines - Qualification and quality control tests of partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters GB/T 22720.2-2019 Rotating electrical machines - Qualification tests for the partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters JB/T 10508-2020 Slot wedges used in small and middle size electric machines - Specification 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 22720.1-2017 and the following apply. 3.1 type I insulation systems insulation systems that do not bear partial discharge during its life for inverter-powered motors 3.2 type II insulation systems insulation systems in which any part may bear partial discharge during its life for inverter-powered motors Note: Generally, Type II insulation systems are used for motors with rated voltage greater than or equal to 700V. 3.3 impulse voltage insulation class; IVIC safe peak to peak voltage specified by the manufacturer and related to the rated voltage for inverter-powered motors, as indicated in the manual and on the nameplate [Source: GB/T 22720.1-2017, 3.19, modified] 3.4 partial discharge; PD electrical discharge that only partially bridges the insulation between conductors Note: PD may occur within the insulation or near conductors. [Source: GB/T 22720.1-2017, 3.1] 3.5 partial discharge inception voltage; PDIV minimum voltage at which partial discharge is first detected in the test circuit when the voltage applied to the test object is gradually increased from a lower value where no PD is observed Note: For sinusoidal voltage, PDIV is defined as the RMS voltage. For impulse voltage, PDIV is defined as the peak to peak voltage. [Source: GB/T 22720.1-2017, 3.2] 3.6 peak (impulse) voltage Up difference between the initial voltage level and the maximum voltage reached during a voltage impulse (as shown by Uₚ in Figure 1) [Source: GB/T 22720.1-2017, 3.4, modified] 3.7 voltage overshoot Ub portion of peak voltage that exceeds the steady-state impulse voltage (see Figure 1) [Source: GB/T 22720.1-2017, 3.6] Key U——voltage; t——time; Up——peak voltage; Ub——voltage overshoot; Ua——steady-state impulse voltage; Upk/pk——peak to peak voltage Figure 1 Schematic diagram of the bipolar symmetric square wave 3.8 peak to peak impulse voltage U'pk/pk peak to peak voltage under impulse repetition conditions (see Figure 2) [Source: GB/T 22720.1-2017, 3.7] Figure 2 Five-phase interphase voltage at motor terminal supplied by three-level inverter 3.9 peak to peak voltage U'pk/pk peak to peak voltage at the fundamental frequency (see Figure 2) [Source: GB/T 22720.1-2017, 3.8] 3.10 impulse rise time tr time required for the peak voltage to rise from the negative level to 100% (see Figure 1) Note: Unless otherwise specified, the impulse rise time is 1.25 times the duration from 10% to 90% of the peak voltage [Source: GB/T 22720.1-2017, 3.13] 3.11 dc bus voltage Udc intermediate circuit voltage (dc link voltage) in a voltage-source inverter [Source: GB/T 22720.1-2017, 3.23] 3.12 rated voltage UN voltage value of the motor under the power-frequency operating condition, which is specified by the manufacturer and marked on the nameplate Note 1: The rated voltage refers to the line-to-line rated voltage (RMS value). Note 2: For electric vehicle drive motors, the rated voltage is the nominal dc bus voltage declared by the manufacturer, where UN = Udc. [Source: GB/T 22720.1-2017, 3.18] 3.13 overshoot factor; OF ratio of the motor terminal voltage to the inverter output voltage [Source: GB/T 22720.1-2017, 3.24]
Contents Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Technical requirements 5 Test methods and test equipment 6 Inspection relus Annex A (Normative) Guidelines for measuring waveform parameters of high-frequency impulse test equipment Annex B (Informative) High-frequency impulse test system and influence factors Annex C (Informative) Measurement of volatile content in impregnating resins Annex D (Informative) Thermal endurance evaluation procedure for insulation systems under special operating conditions - Example of thermal endurance evaluation for insulation systems of new energy vehicle drive motors Annex E (Informative) Evaluation procedure for insulation systems of variable-frequency motors Bibliography Figure 1 Schematic diagram of the bipolar symmetric square wave Figure 2 Five-phase interphase voltage at motor terminal supplied by three-level inverter Figure A.1 Schematic diagram of comparison between "distorted" waveform and standard waveform Figure A.2 Wiring diagram Figure D.1 Temperature cycling curve in diagnostic test Figure E.1 Type I insulation system qualification test flow Figure E.2 Type II insulation system qualification test flow Table 1 General requirements for magnet wires Table 2 Life of enamelled round copper winding wires under high-frequency impulse power supply Table 3 Life of enamelled rectangular copper winding wires under high-frequency impulse power supply Table 4 Life of insulation systems under high-frequency impulse power supply Table 5 Waveform parameters for high-frequency impulse resistance test of magnet wires Table 6 Waveform parameters for high-frequency impulse resistance test of insulation systems Table D.1 Power frequency withstand voltage limits for drive motor windings to ground Table D.2 Turn-to-turn impulse test voltage limits Table D.3 Recommended aging temperatures and exposure times for aging sub-cycles Table D.4 Test voltages Table E.1 Test voltage for various parts of the insulation system of a motor powered by two-level converter (peak to peak value) Table E.2 Relationship between stress types and VC
Referred in GB/T 21707-2025:
*GB/T 4074.7-2024 Test methods of winding wires—Part 7: Test procedure for the determination of the temperature index of enamelled winding wires
*GB/T 5591.3-2018 Combined flexible materials for electrical insulation—Part 3:Specifications for individual materials
*GB/T 6109.1-2008/XG1-2012 Enamelled round winding wire—Part 1:General requirements, includes Amendment 1
*GB/T 7095.1-2008 Enamelled rectangular copper winding wires - Part 1: General requirements
*GB/T 11026.4-2012 Electrical insulating materials—Thermal endurance properties—Part 4:Ageing ovens—Single-chamber ovens
*GB/T 17948.1-2018 Rotating electrical machines—Functional evaluation of insulation systems—Test procedures for wire-wound windings—Thermal evaluation and classification
*GB/T 17948.3-2017 Rotating electrical machines-Functional evaluation of insulation systems- Test procedures for form-wound windings-Thermal evaluation and classification of insulation systems used in rotating machines
*GB/T 20629.3-2019 Non-cellulosic papers for electrical purposes—Part 3: Unfilled aramid (aromatic polyamide) papers
*GB/T 22720.1-2017 Rotating electrical machines-Qualification and quality control tests of partial discharge free electrical insulation systems(Type j)used in rotating electrical machines fed from voltage converters
*GB/T 22720.2-2019 Rotating electrical machines—Qualification tests for the partial discharge resistant electrical insulation systems(Type Ⅱ) used in rotating electrical machines fed from voltage converters
*JB/T 10508-2020 Specifications for slot wedges used in small and middle size electric machines
GB/T 21707-2025 is referred in:
*GB/T 14711-2025 General requirements for safety of small and medium size rotating electrical machines
Code of China
Standard
GB/T 21707-2025  Insulation specification for frequency conversion machine (English Version)
Standard No.GB/T 21707-2025
Statusvalid
LanguageEnglish
File FormatPDF
Word Count17000 words
Price(USD)510.0
Implemented on2025-12-1
Deliveryvia email in 1~3 business day
Detail of GB/T 21707-2025
Standard No.
GB/T 21707-2025
English Name
Insulation specification for frequency conversion machine
Chinese Name
变频调速电机绝缘规范
Chinese Classification
K20
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2025-05-30
Implemented on
2025-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 21707-2018 Insulation specification for variable frequency adjustable speed definite purpose converter-fed three-phase induction motors
Language
English
File Format
PDF
Word Count
17000 words
Price(USD)
510.0
Keywords
GB/T 21707-2025, GB 21707-2025, GBT 21707-2025, GB/T21707-2025, GB/T 21707, GB/T21707, GB21707-2025, GB 21707, GB21707, GBT21707-2025, GBT 21707, GBT21707
Introduction of GB/T 21707-2025
GB/T 21707-2025 Insulation specification for frequency conversion machine 1 Scope This document specifies the technical requirements, test methods, test equipment, and inspection rules for the insulation of frequency conversion machine. This document is applicable to frequency conversion machine with a rated voltage of 1,140V or below. It may serve as a reference for high-voltage frequency conversion motors with rated voltages above 1,140 V. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 4074.7-2024 Test methods of winding wires - Part 7: Test procedure for the determination of the temperature index of enamelled winding wires GB/T 5591.3-2018 Combined flexible materials for electrical insulation - Part 3: Specifications for individual materials GB/T 6109.1 Enamelled round winding wire - Part 1: General requirements GB/T 7095.1 Enamelled rectangular copper winding wires - Part 1: General requirements GB/T 11026.4-2012 Electrical insulating materials - Thermal endurance properties - Part 4: Ageing ovens - Single-chamber ovens GB/T 17948.1-2018 Rotating electrical machines - Functional evaluation of insulation systems - Test procedures for wire-wound windings - Thermal evaluation and classification GB/T 17948.3-2017 Rotating electrical machines - Functional evaluation of insulation systems - Test procedures for form-wound windings - Thermal evaluation and classification of insulation systems used in rotating machines GB/T 20629.3-2019 Non-cellulosic papers for electrical purposes - Part 3: Unfilled aramid (aromatic polyamide) papers GB/T 22720.1-2017 Rotating electrical machines - Qualification and quality control tests of partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters GB/T 22720.2-2019 Rotating electrical machines - Qualification tests for the partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters JB/T 10508-2020 Slot wedges used in small and middle size electric machines - Specification 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 22720.1-2017 and the following apply. 3.1 type I insulation systems insulation systems that do not bear partial discharge during its life for inverter-powered motors 3.2 type II insulation systems insulation systems in which any part may bear partial discharge during its life for inverter-powered motors Note: Generally, Type II insulation systems are used for motors with rated voltage greater than or equal to 700V. 3.3 impulse voltage insulation class; IVIC safe peak to peak voltage specified by the manufacturer and related to the rated voltage for inverter-powered motors, as indicated in the manual and on the nameplate [Source: GB/T 22720.1-2017, 3.19, modified] 3.4 partial discharge; PD electrical discharge that only partially bridges the insulation between conductors Note: PD may occur within the insulation or near conductors. [Source: GB/T 22720.1-2017, 3.1] 3.5 partial discharge inception voltage; PDIV minimum voltage at which partial discharge is first detected in the test circuit when the voltage applied to the test object is gradually increased from a lower value where no PD is observed Note: For sinusoidal voltage, PDIV is defined as the RMS voltage. For impulse voltage, PDIV is defined as the peak to peak voltage. [Source: GB/T 22720.1-2017, 3.2] 3.6 peak (impulse) voltage Up difference between the initial voltage level and the maximum voltage reached during a voltage impulse (as shown by Uₚ in Figure 1) [Source: GB/T 22720.1-2017, 3.4, modified] 3.7 voltage overshoot Ub portion of peak voltage that exceeds the steady-state impulse voltage (see Figure 1) [Source: GB/T 22720.1-2017, 3.6] Key U——voltage; t——time; Up——peak voltage; Ub——voltage overshoot; Ua——steady-state impulse voltage; Upk/pk——peak to peak voltage Figure 1 Schematic diagram of the bipolar symmetric square wave 3.8 peak to peak impulse voltage U'pk/pk peak to peak voltage under impulse repetition conditions (see Figure 2) [Source: GB/T 22720.1-2017, 3.7] Figure 2 Five-phase interphase voltage at motor terminal supplied by three-level inverter 3.9 peak to peak voltage U'pk/pk peak to peak voltage at the fundamental frequency (see Figure 2) [Source: GB/T 22720.1-2017, 3.8] 3.10 impulse rise time tr time required for the peak voltage to rise from the negative level to 100% (see Figure 1) Note: Unless otherwise specified, the impulse rise time is 1.25 times the duration from 10% to 90% of the peak voltage [Source: GB/T 22720.1-2017, 3.13] 3.11 dc bus voltage Udc intermediate circuit voltage (dc link voltage) in a voltage-source inverter [Source: GB/T 22720.1-2017, 3.23] 3.12 rated voltage UN voltage value of the motor under the power-frequency operating condition, which is specified by the manufacturer and marked on the nameplate Note 1: The rated voltage refers to the line-to-line rated voltage (RMS value). Note 2: For electric vehicle drive motors, the rated voltage is the nominal dc bus voltage declared by the manufacturer, where UN = Udc. [Source: GB/T 22720.1-2017, 3.18] 3.13 overshoot factor; OF ratio of the motor terminal voltage to the inverter output voltage [Source: GB/T 22720.1-2017, 3.24]
Contents of GB/T 21707-2025
Contents Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Technical requirements 5 Test methods and test equipment 6 Inspection relus Annex A (Normative) Guidelines for measuring waveform parameters of high-frequency impulse test equipment Annex B (Informative) High-frequency impulse test system and influence factors Annex C (Informative) Measurement of volatile content in impregnating resins Annex D (Informative) Thermal endurance evaluation procedure for insulation systems under special operating conditions - Example of thermal endurance evaluation for insulation systems of new energy vehicle drive motors Annex E (Informative) Evaluation procedure for insulation systems of variable-frequency motors Bibliography Figure 1 Schematic diagram of the bipolar symmetric square wave Figure 2 Five-phase interphase voltage at motor terminal supplied by three-level inverter Figure A.1 Schematic diagram of comparison between "distorted" waveform and standard waveform Figure A.2 Wiring diagram Figure D.1 Temperature cycling curve in diagnostic test Figure E.1 Type I insulation system qualification test flow Figure E.2 Type II insulation system qualification test flow Table 1 General requirements for magnet wires Table 2 Life of enamelled round copper winding wires under high-frequency impulse power supply Table 3 Life of enamelled rectangular copper winding wires under high-frequency impulse power supply Table 4 Life of insulation systems under high-frequency impulse power supply Table 5 Waveform parameters for high-frequency impulse resistance test of magnet wires Table 6 Waveform parameters for high-frequency impulse resistance test of insulation systems Table D.1 Power frequency withstand voltage limits for drive motor windings to ground Table D.2 Turn-to-turn impulse test voltage limits Table D.3 Recommended aging temperatures and exposure times for aging sub-cycles Table D.4 Test voltages Table E.1 Test voltage for various parts of the insulation system of a motor powered by two-level converter (peak to peak value) Table E.2 Relationship between stress types and VC
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 21707-2025, GB 21707-2025, GBT 21707-2025, GB/T21707-2025, GB/T 21707, GB/T21707, GB21707-2025, GB 21707, GB21707, GBT21707-2025, GBT 21707, GBT21707