2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 32790-2016
GB/T 32790-2016   Methods for evaluating the weld quality of seam welds in aluminium and aluminium alloy extrusion (English Version)
Standard No.: GB/T 32790-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):80.0 remind me the price change

Email:

Implemented on:2017-7-1 Delivery: via email in 1 business day

→ → →

,,2017-7-1,9D8F231A9C4E38231474615933255
Standard No.: GB/T 32790-2016
English Name: Methods for evaluating the weld quality of seam welds in aluminium and aluminium alloy extrusion
Chinese Name: 铝及铝合金挤压焊缝焊合性能检验方法
Chinese Classification: H24    Metallographic testing method
Professional Classification: GB    National Standard
ICS Classification: 77.040.99 77.040.99    Other methods of testing of metals 77.040.99
Source Content Issued by: AQSIQ; SAC
Issued on: 2016-08-29
Implemented on: 2017-7-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 80.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the China Nonferrous Metals Industry Association. This standard is under the jurisdiction of National Technical Committee on Nonferrous. Metals of Standardization Administration of China (SAC/TC 243) Methods for evaluating the weld quality of seam welds in aluminium and aluminium alloy extrusion 1 Scope This standard specifies the room temperature inspection method for the weld quality of weld seam in aluminium and aluminium alloy extrusion. This standard is applicable to the inspection of the weld quality of weld seam in aluminium and aluminium alloy extrusion (hereinafter referred to as "weld quality"). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3246.2 Inspection method for structure of wrought aluminum and aluminum alloy products—Part 2: Inspection method for microstructure GB/T 16865 Test pieces for tensile test for wrought aluminum and magnesium alloy products 3 Etching method The test shall be conducted in accordance with those specified in GB/T 3246.2. 4 Fracture method 4.1 Method summery The fracture test is carried out by applying force to the specimen weld seam in extrusion, which causes obvious bending deformation or fracture to the specimen. The weld quality of the weld seam in extrusion is judged according to whether the weld seam in extrusion is broken or the fracture conditions. This method is applicable to specimens in artificial aging state. 4.2 Test device 4.2.1 Test machine: hydraulic or mechanical pressure tester or universal material test machine. 4.2.2 For a fracture test device equipped with support and pressure head (as shown in Figure 1), the hardness of support and pressure head is not less than HRC45, the shape of pressure head is shown in Figure 1 (choose one from the figures), and the arc diameter D of the pressure head is not more than 8mm. a) The weld seam in extrusion is basically perpendicular to the profile surface b) The weld seam in extrusion is obviously not perpendicular to the profile surface Keys: 1——pressure head; 2——weld seam; 3——specimen; 4——support; D——pressure head diameter; a——specimen thickness; l——support span. Figure 1 Schematic diagram of specimen and fracture fixture 4.3 Specimen preparation 4.3.1 Cut macrostructure specimens according to GB/T 3246.2. If the specimens are acceptable in macrostructure inspection, determine the weld seam position and mark it. 4.3.2 Cut the specimen at the weld seam in extrusion of profile and ensure that the weld seam is located in the middle of the specimen. 4.4 Test procedure 4.4.1 Mount the fixture on the test machine and ensure the coaxiality. 4.4.2 Adjust the support span, which shall be determined using Equation (1): (1) where, D——the pressure head diameter, mm; a——the specimen thickness, mm; l——the support span, mm; 4.4.3 Mount the specimen on the fixture. When the weld seam is basically perpendicular to the profile surface, the weld seam of the specimen shall be located on the axis of the fixture [as shown in Figure 1a)]. When the weld seam is obviously not perpendicular to the profile surface, the weld seam in extrusion on the bending surface of the specimen shall be located on the axis of the fixture [as shown in Figure 1b)]. If there is any special requirement, the position for force application shall be determined through negotiation between the supplier and the purchaser. 4.4.4 The fracture test shall be carried out at a test speed not less than 10 mm/min until the bending angle of the specimen reaches 180° or the specimen breaks. 4.5 Result evaluation 4.5.1 If the weld seam is not broken, the weld quality is judged as acceptable. 4.5.2 If the fracture surface of the weld seam is fibrous (see Figure 2 for fibrous fracture conditions), the weld quality is judged as acceptable. 4.5.3 If the edge of the weld seam fracture is in the shape of shear lip (see Figure 2 for the shear-lip-shaped conditions), or the fracture forms an angle of about 45° with the surface of the specimen, the weld quality is judged as acceptable. 4.5.4 If the weld seam fracture is shown as smooth and straight (see Figure 2 for smooth and straight fracture conditions), the weld quality is judged as rejectable. 4.5.5 If the weld seam fracture conditions are characterized by the coexistence appearance of smooth, straight fracture and fibrous fracture and/or shear-lip-shaped fracture (as shown in Figure 2), the weld quality is judged as rejectable.
Foreword i 1 Scope 2 Normative references 3 Etching method 4 Fracture method 5 Flaring method 6 Tension method 7 Test report
Referred in GB/T 32790-2016:
*GB/T 3246.2-2012 Inspection method for structure of wrought aluminum and aluminum alloy products - Part 2: Inspection method for macrostructure
*GB/T 16865-2023 Test pieces and methods for tensile test for wrought aluminium,magnesium and their alloy products
*GB/T 32726-2016 Soil quality; field soil description
*GB/T 32724-2016 Format for recording soil and site information
*GB/T 19766-2016 Specification for natural marble for building slab
*GB/T 18254-2016 High-carbon chromium bearing steel
*GB/T 15712-2016 Microalloyed medium crabon steels
*GB/T 14048.10-2016 Low - voltage switchgear and controlgear - Part 5-2: Control circuit appliances and switching elements - Proximity switches
*GB/T 9567-2016 Melamine for industrial use
*GB/T 6556-2016 Type, main dimensions, material and identification of mechanical seals
*GB/T 4502-2016 Laboratory test methods for passenger car tyres capabilities
GB/T 32790-2016 is referred in:
*GB/T 6893-2022 Aluminium and aluminium alloys cold drawn (rolled) tubes
*GB 5009.179-2016 National Food Safety Standard - Determination of trimethylamine in food
*GB 5009.169-2016 National Food Safety Standard Determination of Taurine in Foods
*GB 5009.157-2016 National Food Safety Standard - Determination of organic acids in food
*GB 5009.141-2016 National Food Safety Standard - Determination of lure red in food
*GB 5009.121-2016 National Food Safety Standard - Determination of dehydroacetic acid in food
*GB 5009.248-2016 National Food Safety Standard Determination of Lutein in Foods
*GB 5009.247-2016 National Food Safety Standard - Determination of neotame in food
*GB 5009.246-2016 National Food Safety Standard - Determination of titania in food
*GB 5009.237-2016 National Food Safety Standard - Determination of pH value of food
*GB 31604.7-2016 National Food Safety Standard - Food Contact Materials and Articles - Decolorization Test
*GB 5009.3-2016 National Food Safety Standard - Determination of Moisture Content in Foods
*GB 1886.230-2016 National Food Safety Standard — Food Additives- ascorbyl palmitate
*GB/T 6892-2023 Wrought aluminium and aluminium alloys extruded profiles for general engineering
Code of China
Standard
GB/T 32790-2016  Methods for evaluating the weld quality of seam welds in aluminium and aluminium alloy extrusion (English Version)
Standard No.GB/T 32790-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)80.0
Implemented on2017-7-1
Deliveryvia email in 1 business day
Detail of GB/T 32790-2016
Standard No.
GB/T 32790-2016
English Name
Methods for evaluating the weld quality of seam welds in aluminium and aluminium alloy extrusion
Chinese Name
铝及铝合金挤压焊缝焊合性能检验方法
Chinese Classification
H24
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2016-08-29
Implemented on
2017-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
80.0
Keywords
GB/T 32790-2016, GB 32790-2016, GBT 32790-2016, GB/T32790-2016, GB/T 32790, GB/T32790, GB32790-2016, GB 32790, GB32790, GBT32790-2016, GBT 32790, GBT32790
Introduction of GB/T 32790-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the China Nonferrous Metals Industry Association. This standard is under the jurisdiction of National Technical Committee on Nonferrous. Metals of Standardization Administration of China (SAC/TC 243) Methods for evaluating the weld quality of seam welds in aluminium and aluminium alloy extrusion 1 Scope This standard specifies the room temperature inspection method for the weld quality of weld seam in aluminium and aluminium alloy extrusion. This standard is applicable to the inspection of the weld quality of weld seam in aluminium and aluminium alloy extrusion (hereinafter referred to as "weld quality"). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3246.2 Inspection method for structure of wrought aluminum and aluminum alloy products—Part 2: Inspection method for microstructure GB/T 16865 Test pieces for tensile test for wrought aluminum and magnesium alloy products 3 Etching method The test shall be conducted in accordance with those specified in GB/T 3246.2. 4 Fracture method 4.1 Method summery The fracture test is carried out by applying force to the specimen weld seam in extrusion, which causes obvious bending deformation or fracture to the specimen. The weld quality of the weld seam in extrusion is judged according to whether the weld seam in extrusion is broken or the fracture conditions. This method is applicable to specimens in artificial aging state. 4.2 Test device 4.2.1 Test machine: hydraulic or mechanical pressure tester or universal material test machine. 4.2.2 For a fracture test device equipped with support and pressure head (as shown in Figure 1), the hardness of support and pressure head is not less than HRC45, the shape of pressure head is shown in Figure 1 (choose one from the figures), and the arc diameter D of the pressure head is not more than 8mm. a) The weld seam in extrusion is basically perpendicular to the profile surface b) The weld seam in extrusion is obviously not perpendicular to the profile surface Keys: 1——pressure head; 2——weld seam; 3——specimen; 4——support; D——pressure head diameter; a——specimen thickness; l——support span. Figure 1 Schematic diagram of specimen and fracture fixture 4.3 Specimen preparation 4.3.1 Cut macrostructure specimens according to GB/T 3246.2. If the specimens are acceptable in macrostructure inspection, determine the weld seam position and mark it. 4.3.2 Cut the specimen at the weld seam in extrusion of profile and ensure that the weld seam is located in the middle of the specimen. 4.4 Test procedure 4.4.1 Mount the fixture on the test machine and ensure the coaxiality. 4.4.2 Adjust the support span, which shall be determined using Equation (1): (1) where, D——the pressure head diameter, mm; a——the specimen thickness, mm; l——the support span, mm; 4.4.3 Mount the specimen on the fixture. When the weld seam is basically perpendicular to the profile surface, the weld seam of the specimen shall be located on the axis of the fixture [as shown in Figure 1a)]. When the weld seam is obviously not perpendicular to the profile surface, the weld seam in extrusion on the bending surface of the specimen shall be located on the axis of the fixture [as shown in Figure 1b)]. If there is any special requirement, the position for force application shall be determined through negotiation between the supplier and the purchaser. 4.4.4 The fracture test shall be carried out at a test speed not less than 10 mm/min until the bending angle of the specimen reaches 180° or the specimen breaks. 4.5 Result evaluation 4.5.1 If the weld seam is not broken, the weld quality is judged as acceptable. 4.5.2 If the fracture surface of the weld seam is fibrous (see Figure 2 for fibrous fracture conditions), the weld quality is judged as acceptable. 4.5.3 If the edge of the weld seam fracture is in the shape of shear lip (see Figure 2 for the shear-lip-shaped conditions), or the fracture forms an angle of about 45° with the surface of the specimen, the weld quality is judged as acceptable. 4.5.4 If the weld seam fracture is shown as smooth and straight (see Figure 2 for smooth and straight fracture conditions), the weld quality is judged as rejectable. 4.5.5 If the weld seam fracture conditions are characterized by the coexistence appearance of smooth, straight fracture and fibrous fracture and/or shear-lip-shaped fracture (as shown in Figure 2), the weld quality is judged as rejectable.
Contents of GB/T 32790-2016
Foreword i 1 Scope 2 Normative references 3 Etching method 4 Fracture method 5 Flaring method 6 Tension method 7 Test report
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 32790-2016, GB 32790-2016, GBT 32790-2016, GB/T32790-2016, GB/T 32790, GB/T32790, GB32790-2016, GB 32790, GB32790, GBT32790-2016, GBT 32790, GBT32790