2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5009.121-2016
GB 5009.121-2016   National Food Safety Standard - Determination of dehydroacetic acid in food (English Version)
Standard No.: GB 5009.121-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):80.0 remind me the price change

Email:

Implemented on:2017-3-1 Delivery: via email in 1 business day

→ → →

,,2017-3-1,274EAC0321D242C41474801198687
Standard No.: GB 5009.121-2016
English Name: National Food Safety Standard - Determination of dehydroacetic acid in food
Chinese Name: 食品安全国家标准 食品中脱氢乙酸的测定
Chinese Classification: X09    Hygiene, safety and labor protection
Professional Classification: GB    National Standard
Source Content Issued by: National Health and Family Planning Commission
Issued on: 2016-08-31
Implemented on: 2017-3-1
Status: valid
Superseding:GB/T 5009.121-2003 Determination of dehydroacetic acid in foods
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 80.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB/T 5009.121-2003 Determination of Dehydroacetic Acid in Foods. The following main changes have been made with respect to GB/T 5009.121-2003: ——This standard is renamed as National Food Safety Standard - Determination of Dehydroacetic Acid in Foods ——Liquid chromatography is added; ——Liquid chromatography given in GB/T 23377-2009 is adopted; ——Classification of specimens is added; ——Preparation and extraction methods of the sample in gas chromatography are improved; ——Chromatographic conditions of gas chromatography are modified. National Food Safety Standard Determination of Dehydroacetic Acid in Foods 1 Scope This standard specifies determination methods of dehydroacetic acid content in fruit and vegetable juices, fruit and vegetable pulps, pickles, fermented bean products, butter, breads, pastries, baked food fillings, compound flavoring, preprocessed meat products and cooked meat products. This standard is applicable to the determination of dehydroacetic acid content in fruit and vegetable juices, fruit and vegetable pulps, pickles, fermented bean products, butter, breads, pastries, baked food fillings, compound flavoring, preprocessed meat products and cooked meat products; other foods may also refer to this standard. Method I Gas Chromatography 2 Principle For solid (semi-solid) sample, pull down the protein and extract with ethyl acetate after degreasing and acidification; for samples of fruit and vegetable juices and pulps, extract with ethyl acetate after acidification; separate and determine with the gas chromatograph equipped with hydrogen flame ionization detector, conduct the qualitative determination according to the retention time of chromatographic peak and conduct the quantitative determination by external standard method. 3 Reagents and Materials Unless otherwise specified, analytically-pure reagents and Class-II water (defined in GB/T 6682) are adopted for the purpose of this method. 3.1 Reagents 3.1.1 Ethyl acetate (C4H8O2): chromatographically pure. 3.1.2 n-hexane (C6H14): chromatographically pure. 3.1.3 Hydrochloric acid (HCl) 3.1.4 Zinc sulfate (ZnSO4•7H2O) 3.1.5 Sodium hydroxide (NaOH). 3.2 Preparation of reagents 3.2.1 Hydrochloric acid solution (1+1, volume ratio): measure 50 mL hydrochloric acid and add into 50 mL water. 3.2.2 Zinc sulphate solution (120 g/L): weigh 12 g zinc sulfate, dissolve it and dilute with water to 100 mL. 3.2.3 Sodium hydroxide solution (20 g/L): weigh 2 g sodium hydroxide, dissolve it and dilute with water to 100 mL. 3.3 Standard product Dehydroacetic acid (C8H8O4; CAS: 520-45-6) standard product: purity ≥ 99.5%. 3.4 Preparation of standard solutions 3.4.1 Dehydroacetic acid standard stock solution (1.0 mg/mL): accurately weigh 0.1000 g (accurate to 0.0001g) dehydroacetic acid standard product into a 100 mL volumetric flask, dissolve with ethyl acetate and scale the volume, preserve the solution at 4℃, which will be valid for 3 months. 3.4.2 Dehydroacetic acid standard working solution: accurately pipet 0.01 mL, 0.1 mL, 0.5 mL, 1.0 mL and 2.0 mL into 10mL volumetric flasks respectively, dilute with ethyl acetate and scale the volume, prepare into the standard working solutions with the concentrations of 1.00 μg/mL, 10.0 μg/mL, 50.0 μg/mL, 100 μg/mL and 200 μg/mL, preserve at 4℃, which will be valid for 1 month. 4 Instruments and Apparatus 4.1 Gas chromatograph, equipped with hydrogen flame ionization detector. 4.2 Balance: with sensibility of 0.1 mg and 1 mg. 4.3 Centrifuge: rotation speed ≥ 4000 r/min. 4.4 Ultrasonic cleaner: with power of 35 kW. 4.5 Grinder. 4.6 Stainless steel high-speed homogenizer. 4.7 pH meter. 5 Analysis Steps 5.1 Preparation of specimens 5.1.1 Fruit and vegetable juices and pulps: weigh 2 g ~ 5 g sample (accurate to 0.001 g), put into a 50 mL centrifugal tube, add 10 mL water, shake for 1 min, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake and extract for 2 min, keep still for layering, take the supernatant for the determination by gas chromatography. 5.1.2 Pickles and fermented bean products; homogenize the sample with stainless steel high-speed homogenizer. Weigh 2 g ~ 5 g (accurate to 0.001 g) samples, put into 50 mL centrifugal tubes, add about 15 mL water, 2.5 mL zinc sulphate solution (3.2.2), adjust pH to 7.5 with sodium hydroxide solution (3.2.3), conduct the ultrasonic extraction for 15 min, transfer to a 25 mL volumetric flask, and scale the volume with water. Transfer the sample solutions into the centrifugal tubes and centrifuge for 10 min at the rotation speed of 4000 r/min. Take 10 mL supernatant, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake for 2 min, keep still for layering and take the supernatant for the determination by gas chromatography. 5.1.3 Bread, pastries, baked food fillings, compound flavoring, preprocessed meat products and cooked meat products: grind the sample with a grinder or homogenize with stainless steel high-speed homogenizer. Weigh 2 g ~ 5 g (accurate to 0.001 g) sample, put into a 50 mL centrifugal tube, add about 15 mL water and 2.5 mL zinc sulphate solution (3.2.2), adjust the pH to 7.5 with sodium hydroxide solution (3.2.3), conduct the ultrasonic extraction for 15 min, transfer to a 25 mL volumetric flask and scale the volume with water. Transfer the sample solution into the separating funnel, add 5 mL n-hexane, shake for 1 min, keep still for layering, take lower-part water phase into the centrifugal tube, centrifuge for 10 min at the rotation speed of 4000 r/min. Take 10 mL supernatant, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake for 2 min, keep still for layering, take the supernatant for the determination by gas chromatography. 5.1.4 Butter: Weigh 2 g ~ 5 g (accurate to 0.001 g) sample, put into a 50 mL centrifugal tube, add about 15 mL water and 2.5 mL zinc sulphate solution (3.2.2), adjust the pH to 7.5 with sodium hydroxide solution (3.2.3), conduct the ultrasonic extraction for 15 min, transfer to a 25 mL volumetric flask and scale the volume with water. Transfer the sample solution into the separating funnel, add 5 mL n-hexane, shake for 1min, keep still for layering, take lower-part water phase into the centrifugal tube, centrifuge for 10 min at the rotation speed of 4000 r/min. Take 10 mL supernatant, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake for 2 min, keep still for layering, take the supernatant for the determination by gas chromatography. 5.2 Reference conditions of instruments 5.2.1 Capillary column: polar capillary column (chemical bonding and stationary phase of polyethylene glycol, 30 m × 0.32 mm × 0.25 μm) or equivalent. 5.2.2 Temperature rising procedure of column: with initial temperature of 150℃, rise to 210℃ at a rate of 10℃/min, rise to 240℃ at a rate of 20℃/min and maintain for 2 min. 5.2.3 Temperature of injection port: 240℃ 5.2.4 Temperature of detector: 300℃. 5.2.5 Flow rate of carrier gas (N2): 1.0 mL/min. 5.2.6 Split injection: 5:1 for splitting ratio and 1.0 μL for injection volume.
Foreword i 1 Scope 2 Principle 3 Reagents and Materials 4 Instruments and Apparatus 5 Analysis Steps 6 Expression of Analysis Results 7 Accuracy 8 Other 9 Principle 10 Reagents and Materials 11 Instruments and Apparatus 12 Analysis Steps 13 Expression of Analysis Results 14 Accuracy 15 Other Annex A Gas Chromatogram of Dehydroacetic Acid Annex B Liquid Chromatogram of Dehydroacetic Acid
Referred in GB 5009.121-2016:
*GB 5009.248-2016 National Food Safety Standard Determination of Lutein in Foods
*GB 5009.247-2016 National Food Safety Standard - Determination of neotame in food
*GB 5009.246-2016 National Food Safety Standard - Determination of titania in food
*GB 5009.237-2016 National Food Safety Standard - Determination of pH value of food
*GB 31604.7-2016 National Food Safety Standard - Food Contact Materials and Articles - Decolorization Test
*GB 5009.3-2016 National Food Safety Standard - Determination of Moisture Content in Foods
*GB 1886.230-2016 National Food Safety Standard — Food Additives- ascorbyl palmitate
*GB/T 32790-2016 Methods for evaluating the weld quality of seam welds in aluminium and aluminium alloy extrusion
*GB/T 32726-2016 Soil quality; field soil description
*GB/T 32724-2016 Format for recording soil and site information
*GB/T 19766-2016 Specification for natural marble for building slab
GB 5009.121-2016 is referred in:
*GB 13022-1991 Plastics-Determination of tensile properties of films
*GB/T 32918.2-2016 Elliptic Curve Public - Key Cryptography Part 2: Digital Signature Algorithm
*GB/T 32918.1-2016 Information security techniques - Elliptic Curve public - key cryptography - Part 1: General
*GB 5009.239-2016 National Food Safety Standard -Determination of Acidity in Foods
*GB 5009.227-2016 National Food Safety Standard - Determination of peroxide value in food
*GB 5009.226-2016 National Food Safety Standard - Determination of Hydrogen Peroxide Residual Quantity in Foods
*GB 5009.210-2016 National Food Safety Standard - Determination of pantothenic acid in food
*GB 5009.179-2016 National Food Safety Standard - Determination of trimethylamine in food
*GB 5009.169-2016 National Food Safety Standard Determination of Taurine in Foods
*GB 5009.157-2016 National Food Safety Standard - Determination of organic acids in food
*GB 5009.141-2016 National Food Safety Standard - Determination of lure red in food
Code of China
Standard
GB 5009.121-2016  National Food Safety Standard - Determination of dehydroacetic acid in food (English Version)
Standard No.GB 5009.121-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)80.0
Implemented on2017-3-1
Deliveryvia email in 1 business day
Detail of GB 5009.121-2016
Standard No.
GB 5009.121-2016
English Name
National Food Safety Standard - Determination of dehydroacetic acid in food
Chinese Name
食品安全国家标准 食品中脱氢乙酸的测定
Chinese Classification
X09
Professional Classification
GB
ICS Classification
Issued by
National Health and Family Planning Commission
Issued on
2016-08-31
Implemented on
2017-3-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 5009.121-2003 Determination of dehydroacetic acid in foods
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
80.0
Keywords
GB 5009.121-2016, GB/T 5009.121-2016, GBT 5009.121-2016, GB5009.121-2016, GB 5009.121, GB5009.121, GB/T5009.121-2016, GB/T 5009.121, GB/T5009.121, GBT5009.121-2016, GBT 5009.121, GBT5009.121
Introduction of GB 5009.121-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB/T 5009.121-2003 Determination of Dehydroacetic Acid in Foods. The following main changes have been made with respect to GB/T 5009.121-2003: ——This standard is renamed as National Food Safety Standard - Determination of Dehydroacetic Acid in Foods ——Liquid chromatography is added; ——Liquid chromatography given in GB/T 23377-2009 is adopted; ——Classification of specimens is added; ——Preparation and extraction methods of the sample in gas chromatography are improved; ——Chromatographic conditions of gas chromatography are modified. National Food Safety Standard Determination of Dehydroacetic Acid in Foods 1 Scope This standard specifies determination methods of dehydroacetic acid content in fruit and vegetable juices, fruit and vegetable pulps, pickles, fermented bean products, butter, breads, pastries, baked food fillings, compound flavoring, preprocessed meat products and cooked meat products. This standard is applicable to the determination of dehydroacetic acid content in fruit and vegetable juices, fruit and vegetable pulps, pickles, fermented bean products, butter, breads, pastries, baked food fillings, compound flavoring, preprocessed meat products and cooked meat products; other foods may also refer to this standard. Method I Gas Chromatography 2 Principle For solid (semi-solid) sample, pull down the protein and extract with ethyl acetate after degreasing and acidification; for samples of fruit and vegetable juices and pulps, extract with ethyl acetate after acidification; separate and determine with the gas chromatograph equipped with hydrogen flame ionization detector, conduct the qualitative determination according to the retention time of chromatographic peak and conduct the quantitative determination by external standard method. 3 Reagents and Materials Unless otherwise specified, analytically-pure reagents and Class-II water (defined in GB/T 6682) are adopted for the purpose of this method. 3.1 Reagents 3.1.1 Ethyl acetate (C4H8O2): chromatographically pure. 3.1.2 n-hexane (C6H14): chromatographically pure. 3.1.3 Hydrochloric acid (HCl) 3.1.4 Zinc sulfate (ZnSO4•7H2O) 3.1.5 Sodium hydroxide (NaOH). 3.2 Preparation of reagents 3.2.1 Hydrochloric acid solution (1+1, volume ratio): measure 50 mL hydrochloric acid and add into 50 mL water. 3.2.2 Zinc sulphate solution (120 g/L): weigh 12 g zinc sulfate, dissolve it and dilute with water to 100 mL. 3.2.3 Sodium hydroxide solution (20 g/L): weigh 2 g sodium hydroxide, dissolve it and dilute with water to 100 mL. 3.3 Standard product Dehydroacetic acid (C8H8O4; CAS: 520-45-6) standard product: purity ≥ 99.5%. 3.4 Preparation of standard solutions 3.4.1 Dehydroacetic acid standard stock solution (1.0 mg/mL): accurately weigh 0.1000 g (accurate to 0.0001g) dehydroacetic acid standard product into a 100 mL volumetric flask, dissolve with ethyl acetate and scale the volume, preserve the solution at 4℃, which will be valid for 3 months. 3.4.2 Dehydroacetic acid standard working solution: accurately pipet 0.01 mL, 0.1 mL, 0.5 mL, 1.0 mL and 2.0 mL into 10mL volumetric flasks respectively, dilute with ethyl acetate and scale the volume, prepare into the standard working solutions with the concentrations of 1.00 μg/mL, 10.0 μg/mL, 50.0 μg/mL, 100 μg/mL and 200 μg/mL, preserve at 4℃, which will be valid for 1 month. 4 Instruments and Apparatus 4.1 Gas chromatograph, equipped with hydrogen flame ionization detector. 4.2 Balance: with sensibility of 0.1 mg and 1 mg. 4.3 Centrifuge: rotation speed ≥ 4000 r/min. 4.4 Ultrasonic cleaner: with power of 35 kW. 4.5 Grinder. 4.6 Stainless steel high-speed homogenizer. 4.7 pH meter. 5 Analysis Steps 5.1 Preparation of specimens 5.1.1 Fruit and vegetable juices and pulps: weigh 2 g ~ 5 g sample (accurate to 0.001 g), put into a 50 mL centrifugal tube, add 10 mL water, shake for 1 min, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake and extract for 2 min, keep still for layering, take the supernatant for the determination by gas chromatography. 5.1.2 Pickles and fermented bean products; homogenize the sample with stainless steel high-speed homogenizer. Weigh 2 g ~ 5 g (accurate to 0.001 g) samples, put into 50 mL centrifugal tubes, add about 15 mL water, 2.5 mL zinc sulphate solution (3.2.2), adjust pH to 7.5 with sodium hydroxide solution (3.2.3), conduct the ultrasonic extraction for 15 min, transfer to a 25 mL volumetric flask, and scale the volume with water. Transfer the sample solutions into the centrifugal tubes and centrifuge for 10 min at the rotation speed of 4000 r/min. Take 10 mL supernatant, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake for 2 min, keep still for layering and take the supernatant for the determination by gas chromatography. 5.1.3 Bread, pastries, baked food fillings, compound flavoring, preprocessed meat products and cooked meat products: grind the sample with a grinder or homogenize with stainless steel high-speed homogenizer. Weigh 2 g ~ 5 g (accurate to 0.001 g) sample, put into a 50 mL centrifugal tube, add about 15 mL water and 2.5 mL zinc sulphate solution (3.2.2), adjust the pH to 7.5 with sodium hydroxide solution (3.2.3), conduct the ultrasonic extraction for 15 min, transfer to a 25 mL volumetric flask and scale the volume with water. Transfer the sample solution into the separating funnel, add 5 mL n-hexane, shake for 1 min, keep still for layering, take lower-part water phase into the centrifugal tube, centrifuge for 10 min at the rotation speed of 4000 r/min. Take 10 mL supernatant, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake for 2 min, keep still for layering, take the supernatant for the determination by gas chromatography. 5.1.4 Butter: Weigh 2 g ~ 5 g (accurate to 0.001 g) sample, put into a 50 mL centrifugal tube, add about 15 mL water and 2.5 mL zinc sulphate solution (3.2.2), adjust the pH to 7.5 with sodium hydroxide solution (3.2.3), conduct the ultrasonic extraction for 15 min, transfer to a 25 mL volumetric flask and scale the volume with water. Transfer the sample solution into the separating funnel, add 5 mL n-hexane, shake for 1min, keep still for layering, take lower-part water phase into the centrifugal tube, centrifuge for 10 min at the rotation speed of 4000 r/min. Take 10 mL supernatant, add 1 mL hydrochloric acid solution (3.2.1) for acidification, accurately add 5.0 mL ethyl acetate, shake for 2 min, keep still for layering, take the supernatant for the determination by gas chromatography. 5.2 Reference conditions of instruments 5.2.1 Capillary column: polar capillary column (chemical bonding and stationary phase of polyethylene glycol, 30 m × 0.32 mm × 0.25 μm) or equivalent. 5.2.2 Temperature rising procedure of column: with initial temperature of 150℃, rise to 210℃ at a rate of 10℃/min, rise to 240℃ at a rate of 20℃/min and maintain for 2 min. 5.2.3 Temperature of injection port: 240℃ 5.2.4 Temperature of detector: 300℃. 5.2.5 Flow rate of carrier gas (N2): 1.0 mL/min. 5.2.6 Split injection: 5:1 for splitting ratio and 1.0 μL for injection volume.
Contents of GB 5009.121-2016
Foreword i 1 Scope 2 Principle 3 Reagents and Materials 4 Instruments and Apparatus 5 Analysis Steps 6 Expression of Analysis Results 7 Accuracy 8 Other 9 Principle 10 Reagents and Materials 11 Instruments and Apparatus 12 Analysis Steps 13 Expression of Analysis Results 14 Accuracy 15 Other Annex A Gas Chromatogram of Dehydroacetic Acid Annex B Liquid Chromatogram of Dehydroacetic Acid
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5009.121-2016, GB/T 5009.121-2016, GBT 5009.121-2016, GB5009.121-2016, GB 5009.121, GB5009.121, GB/T5009.121-2016, GB/T 5009.121, GB/T5009.121, GBT5009.121-2016, GBT 5009.121, GBT5009.121