2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 7673.3-2008
GB/T 7673.3-2008   Paper covered wires - Part 3: Paper covered rectangular copper wire (English Version)
Standard No.: GB/T 7673.3-2008 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):224.0 remind me the price change

Email:

Implemented on:2008-10-1 Delivery: via email in 1 business day

→ → →

,2012-9-1,2008-10-1,141138181858466BBA51E0D40F8D5
Standard No.: GB/T 7673.3-2008
English Name: Paper covered wires - Part 3: Paper covered rectangular copper wire
Chinese Name: 纸包绕组线 第3部分: 纸包铜扁线
Chinese Classification: K12    Wire with insulation layer
Professional Classification: GB    National Standard
ICS Classification: 29.060.10 29.060.10    Wires 29.060.10
Source Content Issued by: AQSIQ; SAC
Issued on: 2008-3-24
Implemented on: 2008-10-1
Status: superseded
Superseded by:GB/T 7673.3-2008/XG1-2012 Paper covered wires - Part 3: Paper covered rectangular copper wire
Superseded on:2012-9-1
Superseding:GB/T 7673.3-1987
GB 7673.3-1987 Paper covered wires-Part 3:Paper covered rectangular wires
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 224.0
Delivery: via email in 1 business day
This part of GB/T 7673 specifies the requirements of paper covered rectangular copper wire. The insulation paper consists of two or more insulating layers and intended for winding for transformers and other electric apparatus. The range of nominal conductor dimensions covered by this part is: Wider side b: (2.00≤b≤16.00)mm Narrow side a: (0.80≤a≤5.60)mm Insulation paper covered by this part are restricted to those specified in IEC 60554-1 having thickness in the range 0.025mm ~0.125mm. When a reference is made to winding wire according to this part, the following information shall be given (or expressed according to GB/T 7673.1-2008, 3.4) ——IEC 60317-27; ——Nominal conductor dimensions, mm; ——Nominal thickness of paper insulation, mm. Example: IEC 60317-27 4.00×1.00+0.20 or ZB 0.20-1.00×4.00 and GB/T 7673.3-2008
Foreword I 1 Scope 2 Normative References 3 Definition, General Notes on Test Methods and Appearance 4 Dimensions 5 Electrical Resistance 6 Elongation 7 Springiness 8 Flexibility and Adherence 9 Acceptance Rules Annex A (Informative) Comparison Table Between This Part and IEC 60317-27: 1998 in Clause Number Annex B (Informative) Technical Differences Between This Part and IEC 60317-27:1998 and Their Reasons
Referred in GB/T 7673.3-2008:
* GB/T 228-2002 Metallic Materials – Tensile Testing at Ambient Temperature
* GB/T 4074.2-2008 Winding wires - Test methods - Part 2: Determination of dimensions
* GB/T 4074.3-2008 Winding wires - Test methods - Part 3: Mechanical properties
* GB/T 4074.5-2008 Winding wires - Test methods - Part 5: Electrical properties
* GB/T 7095.1-2008 Enamelled rectangular copper winding wires - Part 1: General requirements
* GB/T 7673.1-2008 Paper covered wires - Part 1: General requirements
Code of China
Standard
GB/T 7673.3-2008  Paper covered wires - Part 3: Paper covered rectangular copper wire (English Version)
Standard No.GB/T 7673.3-2008
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)224.0
Implemented on2008-10-1
Deliveryvia email in 1 business day
Detail of GB/T 7673.3-2008
Standard No.
GB/T 7673.3-2008
English Name
Paper covered wires - Part 3: Paper covered rectangular copper wire
Chinese Name
纸包绕组线 第3部分: 纸包铜扁线
Chinese Classification
K12
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2008-3-24
Implemented on
2008-10-1
Status
superseded
Superseded by
GB/T 7673.3-2008/XG1-2012 Paper covered wires - Part 3: Paper covered rectangular copper wire
Superseded on
2012-9-1
Abolished on
Superseding
GB/T 7673.3-1987
GB 7673.3-1987 Paper covered wires-Part 3:Paper covered rectangular wires
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
224.0
Keywords
GB/T 7673.3-2008, GB 7673.3-2008, GBT 7673.3-2008, GB/T7673.3-2008, GB/T 7673.3, GB/T7673.3, GB7673.3-2008, GB 7673.3, GB7673.3, GBT7673.3-2008, GBT 7673.3, GBT7673.3
Introduction of GB/T 7673.3-2008
This part of GB/T 7673 specifies the requirements of paper covered rectangular copper wire. The insulation paper consists of two or more insulating layers and intended for winding for transformers and other electric apparatus. The range of nominal conductor dimensions covered by this part is: Wider side b: (2.00≤b≤16.00)mm Narrow side a: (0.80≤a≤5.60)mm Insulation paper covered by this part are restricted to those specified in IEC 60554-1 having thickness in the range 0.025mm ~0.125mm. When a reference is made to winding wire according to this part, the following information shall be given (or expressed according to GB/T 7673.1-2008, 3.4) ——IEC 60317-27; ——Nominal conductor dimensions, mm; ——Nominal thickness of paper insulation, mm. Example: IEC 60317-27 4.00×1.00+0.20 or ZB 0.20-1.00×4.00 and GB/T 7673.3-2008
Contents of GB/T 7673.3-2008
Foreword I 1 Scope 2 Normative References 3 Definition, General Notes on Test Methods and Appearance 4 Dimensions 5 Electrical Resistance 6 Elongation 7 Springiness 8 Flexibility and Adherence 9 Acceptance Rules Annex A (Informative) Comparison Table Between This Part and IEC 60317-27: 1998 in Clause Number Annex B (Informative) Technical Differences Between This Part and IEC 60317-27:1998 and Their Reasons
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 7673.3-2008, GB 7673.3-2008, GBT 7673.3-2008, GB/T7673.3-2008, GB/T 7673.3, GB/T7673.3, GB7673.3-2008, GB 7673.3, GB7673.3, GBT7673.3-2008, GBT 7673.3, GBT7673.3