2025-5-16 18.97.14.82
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/HJ 550-2015
HJ 550-2015   Water quality - Determination of cobalt - 5-CI-PADAB Spectrophotometry (English Version)
Standard No.: HJ 550-2015 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 3000 words Price(USD):220.0 remind me the price change

Email:

Implemented on:2015-7-1 Delivery: via email in 1 business day
,,
Standard No.: HJ 550-2015
English Name: Water quality - Determination of cobalt - 5-CI-PADAB Spectrophotometry
Chinese Name: 水质 钴的测定 5-氯-2-(吡啶偶氮)-1,3-二氨基苯分光光度法
Professional Classification: HJ    Professional Standard - Environment
Issued by: ZHB
Issued on: 2015-04-03
Implemented on: 2015-7-1
Status: valid
Superseding:HJ 550-2009 Water quality - Determination of cobalt - 5-CI-PADAB spectrophotometry
Language: English
File Format: PDF
Word Count: 3000 words
Price(USD): 220.0
Delivery: via email in 1 business day
1 Application scope This standard specifies 5-Cl-PADAB spectrophotometry for determination of dissolved cobalt and total cobalt in water. This standard is applicable to the determination of cobalt in surface water, industrial wastewater and domestic sewage. When the sampling volume is 20.0 mL, the detection limit of the method is 0.009mg/L, the lower limit of determination is 0.036mg/L, and the upper limit of determination is 0.500 mg/L. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For undated references, the latest edition of the normative document applies. HJ/T 91 Technical specifications requirements for monitoring of surface water and waste water 3 Terms and definitions For the purpose of this standard, the following terms and definitions apply. 3.1 Dissolved cobalt the cobalt determined after the non-acidified sample passes through a 0.45μm pore size filter membrane 3.2 Total cobalt the cobalt measured in unfiltered samples, i.e. the sum of dissolved and suspended cobalt in the sample
Foreword i 1 Application scope 2 Normative references 3 Terms and definitions 4 Method principle 5 Interference and elimination 6 Reagents and materials 7 Apparatuses 8 Sample 9 Analytical procedures 10 Result calculation and expression 11 Precision and accuracy 12 Quality assurance and control 13 Waste treatment
Referred in HJ 550-2015:
*HJ/T 91-2002 Technical specifications requirements for monitoring of surface water and waste water
HJ 550-2015 is referred in:
*GB 31573-2015 Emission standards of pollutants for inorganic chemical industry
*GB 31573-2015/XG1-2020 Emission standards of pollutants for inorganic chemical industry, inckudes Amendment 1
*GB 30484-2013 Emission standard of pollutants for battery industry
Code of China
Standard
HJ 550-2015  Water quality - Determination of cobalt - 5-CI-PADAB Spectrophotometry (English Version)
Standard No.HJ 550-2015
Statusvalid
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)220.0
Implemented on2015-7-1
Deliveryvia email in 1 business day
Detail of HJ 550-2015
Standard No.
HJ 550-2015
English Name
Water quality - Determination of cobalt - 5-CI-PADAB Spectrophotometry
Chinese Name
水质 钴的测定 5-氯-2-(吡啶偶氮)-1,3-二氨基苯分光光度法
Chinese Classification
Professional Classification
HJ
ICS Classification
Issued by
ZHB
Issued on
2015-04-03
Implemented on
2015-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
HJ 550-2009 Water quality - Determination of cobalt - 5-CI-PADAB spectrophotometry
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
220.0
Keywords
HJ 550-2015, HJ/T 550-2015, HJT 550-2015, HJ550-2015, HJ 550, HJ550, HJ/T550-2015, HJ/T 550, HJ/T550, HJT550-2015, HJT 550, HJT550
Introduction of HJ 550-2015
1 Application scope This standard specifies 5-Cl-PADAB spectrophotometry for determination of dissolved cobalt and total cobalt in water. This standard is applicable to the determination of cobalt in surface water, industrial wastewater and domestic sewage. When the sampling volume is 20.0 mL, the detection limit of the method is 0.009mg/L, the lower limit of determination is 0.036mg/L, and the upper limit of determination is 0.500 mg/L. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For undated references, the latest edition of the normative document applies. HJ/T 91 Technical specifications requirements for monitoring of surface water and waste water 3 Terms and definitions For the purpose of this standard, the following terms and definitions apply. 3.1 Dissolved cobalt the cobalt determined after the non-acidified sample passes through a 0.45μm pore size filter membrane 3.2 Total cobalt the cobalt measured in unfiltered samples, i.e. the sum of dissolved and suspended cobalt in the sample
Contents of HJ 550-2015
Foreword i 1 Application scope 2 Normative references 3 Terms and definitions 4 Method principle 5 Interference and elimination 6 Reagents and materials 7 Apparatuses 8 Sample 9 Analytical procedures 10 Result calculation and expression 11 Precision and accuracy 12 Quality assurance and control 13 Waste treatment
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 