2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 10739-2007
JB/T 10739-2007   Separable connectors for extruded insulation power cables with rated voltages from 6kV (Um=7.2kV) up to 35kV(Um=40.5kV) (English Version)
Standard No.: JB/T 10739-2007 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 7000 words Translation Price(USD):170.0 remind me the price change

Email:

Implemented on:2007-11-1 Delivery: via email in 1 business day

→ → →

,,2007-11-1,1411375394528331F01347F06E71C
Standard No.: JB/T 10739-2007
English Name: Separable connectors for extruded insulation power cables with rated voltages from 6kV (Um=7.2kV) up to 35kV(Um=40.5kV)
Chinese Name: 额定电压6kV(Um=7.2kV)到35kV(Um=40.5kV)挤包绝缘电力电缆 可分离连接器
Chinese Classification: K13    Cable and its accessory
Professional Classification: JB    Professional Standard - Machinery
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Source Content Issued by: NDRC
Issued on: 2007-5-29
Implemented on: 2007-11-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 7000 words
Translation Price(USD): 170.0
Delivery: via email in 1 business day
1 Scope This standard specifies model and expression method, technical requirements, test methods, inspection rules as well as marking, packaging, transport and storage of separable connector for extruded insulation power cables with rated voltages from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV). This standard is applicable to plug-in type separable connector and bolted-type separable connector for extruded insulation power cables with insulation screen and with rated voltages from 6kV (Um=7.2kV) up to 35KV (Um=40.5kV). The service conditions shall meet those specified in 5.1 and 5.2 of GB/T 12706.4-2002. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this standard. However parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2900.10-2001 Electrotechnical Vocabulary - Electric Cables (idt IEC 60050-461: 1984) GB/T 9327.1~9327.5-1988 Test Methods for Compression and Mechanical Connectors for Conductors of Power Cables GB/T 12706.2-2002 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 2: Cables for Rated Voltages from 6kV (Um=7.2kV) up to 30kV (Um=36kV) (eqv IEC 60502-2: 1997) GB/T 12706.3-2002 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 3: Cables for Rated Voltages of 35kV (Um=40.5kV) (neq IEC 60502-2: 1997) GB/T 12706.4-2002 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 4: Test Requirements on Accessories for Cables with Rated Voltages from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV) (eqv IEC 60502-4: 1997) GB/T 14315-1993 Compression Type Terminal Lugs and Ferrules for Power Cables with Copper or Aluminum Conductors GB/T 18889-2002 Electric Cables - Test Methods for Accessories for Power Cables with Rated Voltage from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV) (IEC 61442: 1997, MOD) 3 Terms and Definitions For the purpose of this standard, the terms and definitions given in GB/T 2900.10-2001 and GB/T 12706.4-2002 apply. 4 Product Model and Expression Method 4.1 Code 4.1.1 Classified by series S——Device end 4.1.2 Classified by type YC——Plug-in type separable connector; YL——Bolted-type separable connector. 4.1.3 Classified by shape feature J——Perpendicular-type;
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Model and Expression Method 4.1 Code 4.2 Product model 4.3 Expression method of products 5 Technical Requirements 6 Test Conditions and Methods 7 Test Result Assessment 8 Range of Approval 9 Inspection Rules 10 Marking, Packaging, Transport and Storage Annex A (Normative) General Technical Requirements for the Rubber Parts and Installation Materials of Separable Connectors Annex B (Informative) Main Performance Requirements for the Rubber Part Material of Separable Connectors Annex C (Informative) Main Performance Requirements of Silicone Grease Lubricant for Installation Annex D (Normative) Test Methods for Resistance Value of Stress Cone and Internally-screened Semi-conductive Layer Annex E (Informative) Identification of Test Cable (See 5.4.1) Figure 1 Test Arrangements and Number of Samples for Separable Connectors Table 1 Selection of Grounding Wire Sectional Area Table 2 Cable Sectional Area Used for Separable Connector Test Table 3 Test Procedures and Requirements Table 4 Range of Approval for Cable Insulation Tested Table 5 Procedures and Requirements for Type Test of Screened Deadbreak Separable Connectors Table 6 Procedures and Requirements for Type Test of Screened Bolted-type Separable Connectors Table 7 Procedures and Requirements for Type Test of Unscreened Separable Connectors (Including Plug-in and Bolted Types) Table 8 Procedures and Requirements for Type Test of Hot Pluggable Separable Connectors Table 9 Procedures and Requirements for Sampling Test of Separable Connectors Table 10 Additional Test Approved for Different Types of Cable Insulation Screen Table B.1 Main Performance Requirements of Insulating Rubber Materials Table B.2 Main Performance Requirements of Semi-Conductive Rubber Materials Table C.1 Main Performance Requirements of Silicone Grease Lubricant for Installation
Referred in JB/T 10739-2007:
*GB/T 2900.10-2001 Electrotechnical vocabulary - Electric cables
*GB/T 12706.2-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV)-Part 1:Cables for rated voltages from 6kV(Um=7.2kV) up to 30kV(Um=36kV)
*GB/T 12706.3-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV)-Part 3:Cables for rated voltages of 35kV(Um=40.5kV)
*GB/T 12706.4-2002 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV)-Part 4:Test requirmeents on accessories for cables with rated voltages from 6kV(Um=7.2kV) up to 35kV(Um=40.5kV)
*GBT14315-1993
*GB/T 18889-2002 Electric cables-test methods for accessories for power cables with rated voltage from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV)
Code of China
Standard
JB/T 10739-2007   Separable connectors for extruded insulation power cables with rated voltages from 6kV (Um=7.2kV) up to 35kV(Um=40.5kV) (English Version)
Standard No.JB/T 10739-2007
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)170.0
Implemented on2007-11-1
Deliveryvia email in 1 business day
Detail of JB/T 10739-2007
Standard No.
JB/T 10739-2007
English Name
Separable connectors for extruded insulation power cables with rated voltages from 6kV (Um=7.2kV) up to 35kV(Um=40.5kV)
Chinese Name
额定电压6kV(Um=7.2kV)到35kV(Um=40.5kV)挤包绝缘电力电缆 可分离连接器
Chinese Classification
K13
Professional Classification
JB
ICS Classification
Issued by
NDRC
Issued on
2007-5-29
Implemented on
2007-11-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
170.0
Keywords
JB/T 10739-2007, JB 10739-2007, JBT 10739-2007, JB/T10739-2007, JB/T 10739, JB/T10739, JB10739-2007, JB 10739, JB10739, JBT10739-2007, JBT 10739, JBT10739
Introduction of JB/T 10739-2007
1 Scope This standard specifies model and expression method, technical requirements, test methods, inspection rules as well as marking, packaging, transport and storage of separable connector for extruded insulation power cables with rated voltages from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV). This standard is applicable to plug-in type separable connector and bolted-type separable connector for extruded insulation power cables with insulation screen and with rated voltages from 6kV (Um=7.2kV) up to 35KV (Um=40.5kV). The service conditions shall meet those specified in 5.1 and 5.2 of GB/T 12706.4-2002. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this standard. However parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 2900.10-2001 Electrotechnical Vocabulary - Electric Cables (idt IEC 60050-461: 1984) GB/T 9327.1~9327.5-1988 Test Methods for Compression and Mechanical Connectors for Conductors of Power Cables GB/T 12706.2-2002 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 2: Cables for Rated Voltages from 6kV (Um=7.2kV) up to 30kV (Um=36kV) (eqv IEC 60502-2: 1997) GB/T 12706.3-2002 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 3: Cables for Rated Voltages of 35kV (Um=40.5kV) (neq IEC 60502-2: 1997) GB/T 12706.4-2002 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 4: Test Requirements on Accessories for Cables with Rated Voltages from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV) (eqv IEC 60502-4: 1997) GB/T 14315-1993 Compression Type Terminal Lugs and Ferrules for Power Cables with Copper or Aluminum Conductors GB/T 18889-2002 Electric Cables - Test Methods for Accessories for Power Cables with Rated Voltage from 6kV (Um=7.2kV) up to 35kV (Um=40.5kV) (IEC 61442: 1997, MOD) 3 Terms and Definitions For the purpose of this standard, the terms and definitions given in GB/T 2900.10-2001 and GB/T 12706.4-2002 apply. 4 Product Model and Expression Method 4.1 Code 4.1.1 Classified by series S——Device end 4.1.2 Classified by type YC——Plug-in type separable connector; YL——Bolted-type separable connector. 4.1.3 Classified by shape feature J——Perpendicular-type;
Contents of JB/T 10739-2007
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Product Model and Expression Method 4.1 Code 4.2 Product model 4.3 Expression method of products 5 Technical Requirements 6 Test Conditions and Methods 7 Test Result Assessment 8 Range of Approval 9 Inspection Rules 10 Marking, Packaging, Transport and Storage Annex A (Normative) General Technical Requirements for the Rubber Parts and Installation Materials of Separable Connectors Annex B (Informative) Main Performance Requirements for the Rubber Part Material of Separable Connectors Annex C (Informative) Main Performance Requirements of Silicone Grease Lubricant for Installation Annex D (Normative) Test Methods for Resistance Value of Stress Cone and Internally-screened Semi-conductive Layer Annex E (Informative) Identification of Test Cable (See 5.4.1) Figure 1 Test Arrangements and Number of Samples for Separable Connectors Table 1 Selection of Grounding Wire Sectional Area Table 2 Cable Sectional Area Used for Separable Connector Test Table 3 Test Procedures and Requirements Table 4 Range of Approval for Cable Insulation Tested Table 5 Procedures and Requirements for Type Test of Screened Deadbreak Separable Connectors Table 6 Procedures and Requirements for Type Test of Screened Bolted-type Separable Connectors Table 7 Procedures and Requirements for Type Test of Unscreened Separable Connectors (Including Plug-in and Bolted Types) Table 8 Procedures and Requirements for Type Test of Hot Pluggable Separable Connectors Table 9 Procedures and Requirements for Sampling Test of Separable Connectors Table 10 Additional Test Approved for Different Types of Cable Insulation Screen Table B.1 Main Performance Requirements of Insulating Rubber Materials Table B.2 Main Performance Requirements of Semi-Conductive Rubber Materials Table C.1 Main Performance Requirements of Silicone Grease Lubricant for Installation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 10739-2007, JB 10739-2007, JBT 10739-2007, JB/T10739-2007, JB/T 10739, JB/T10739, JB10739-2007, JB 10739, JB10739, JBT10739-2007, JBT 10739, JBT10739