2025-5-17 18.97.9.174
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/QB/T 5217-2018
QB/T 5217-2018   Air cleaner for medical environment (English Version)
Standard No.: QB/T 5217-2018 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 9500 words Price(USD):230.0 remind me the price change

Email:

Implemented on:2018-7-1 Delivery: via email in 1 business day
,,
Standard No.: QB/T 5217-2018
English Name: Air cleaner for medical environment
Chinese Name: 医用环境空气净化器
Professional Classification: QB    Professional Standard - Light Industry
Issued by: Ministry of Industry and Information Technology
Issued on: 2018-02-09
Implemented on: 2018-7-1
Status: valid
Language: English
File Format: PDF
Word Count: 9500 words
Price(USD): 230.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by and is under the jurisdiction of the China National Light Industry Council. This standard is issued for the first time. Air cleaner for medical environment 1 Scope This standard specifies the terms and definitions, specification and designation, requirements, test methods, inspection rules, marking, packaging, transportation and storage of air cleaners for medical environment. It is applicable to indoor air cleaners for medical environment and environments with similar cleaning requirements, including: ——cleaners for medical indoor environment, including hospitals, sanatoriums, convalescent hospitals, blood stations and precision instrument rooms; ——cleaners for laboratories, nursing homes, kindergartens, health centers, residential buildings and the like with similar cleaning requirements; ——fresh air ventilators with similar cleaning function can be implemented by reference to this standard. This standard is not applicable to: ——cleaners for hospital clean operating department and specially designed for industrial use; ——cleaners for the special environment and locations of corrosive and explosive gas (such as dust, vapor and gas). Note: See Annex A for Classes II and III hospital environment. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191-2008 Packaging - Pictorial marking for handling of goods GB/T 4214.1-2000 Acoustics - Household and similar electrical appliances - Test code for determination of airborne acoustical noise - Part 1: General requirements GB 4793.1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements GB/T 5080.7-1986 Equipment reliability testing - Compliance test plans for failure rate and mean time between failures assuming constant failure rate GB 9671-1996 Hygienic standard for hospital waiting room GB/T 9969-2008 General principles for preparation of instructions for use of industrial products GB/T 14295-2008 Air filters GB/T 14710-2009 Environmental requirement and test methods for medical electrical equipment GB 15982-2012 Hygienic standard for disinfection in hospitals GB/T 18202-2000 Hygienic standard for ozone in indoor air GB/T 18204.3-2013 Examination methods for public places - Part 3: Airborne microorganism GB/T 18268.1-2010 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements GB/T 18801-2016 Air cleaner JG/T 294-2010 Test of pollutant cleaning performance of air cleaner WS/T 368-2012 Management specification of air cleaning technique in hospitals The Ministry of Health Technical standard for disinfection (Edition 2002) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 air cleaner for medical environment an appliance that has effective removal capability for microorganism, particulate matter and gaseous pollutant in the air and can meet the requirements for medical treatment and similar purposes (hereinafter referred to as "appliance") 3.2 disinfection factor an independent unit used in appliance that can kill natural bacteria in the air and reaches disinfection requirements 3.3 target pollutant specific air pollutant with definite composition Note: It is mainly divided into three categories: particulate matter, gaseous pollutant and microorganism. 3.4 natural decay the reduction of concentration of the target pollutant in the air under specified space and conditions due to non-human factors such as settlement, agglomeration, surface deposition, chemical reaction and air exchange 3.5 total decay the reduction of concentration of the target pollutant in the air under specified space and conditions due to combined action of natural decay and cleaning operation of the appliance 3.6 cleaning efficiency ability of the appliance to remove a certain target pollutant before and after starting up for operation 3.7 one pass cleaning efficiency ratio of the difference between the target pollutant concentration before and after passing through the appliance at one time and the target pollutant concentration before passing through under the rated air volume Note: The value is expressed in %. 3.8 nominal airflow rate the maximum airflow rate at outlet when the appliance is used at rated frequency and rated voltage Note: The value is expressed in m3/h. 3.9 bacterium killing rate ratio of the difference between the bacteria content in the air before the appliance is disinfected (except for naturally extinct bacteria) and the bacteria content in the air at different times during disinfection to the bacteria content in the air before disinfection Note 1: The value is expressed in %. Note 2: Staphylococcus albus is the representative strain in the test. 3.10 natural bacteria extinction rate ratio of the difference between the mean number of natural bacteria in the air before disinfection and that after disinfection to the mean number of natural bacteria in the air before disinfection Note: The value is expressed in %. 3.11 clean air delivery rate; CADR product of one pass cleaning efficiency and nominal airflow rate Note: For the convenience of determination, the clean air delivery rate of air cleaner with nominal airflow rate less than 700m3/h may be obtained in accordance with the decay method specified in GB/T 18801-2015. 4 Specification and designation 4.1 Specification The nominal airflow rate is taken as the rule of designation and basic parameter for the appliance. Note: The value is expressed in m3/h. 4.2 Designation of product model Example: YKJ-A011600B where: YKJ——the medical air cleaner; A01——item 1 of series A; 1600——the nominal airflow rate is 1 600m3/h; B——the second improved design. 5 Requirements 5.1 Appearance 5.1.1 The cleaner shall be upright in shape, clean and smooth in surface, uniform in color and luster, and free from defects such as blisters, cracks, rust and sharp edges as well as obvious scratches and bumps on the surface. 5.1.2 The words, symbols and graphic signs explaining functions on the outer surface shall be marked clearly, accurately and firmly. 5.1.3 Each control device shall be flexible, reliable and free from blockage. Fasteners shall be installed firmly without looseness. 5.2 Nominal airflow rate The measured nominal airflow rate of the appliance shall not be less than 90% of the nominal value.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Specification and designation 5 Requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transportation and storage Annex A (Informative) Requirements of Classes II and III hospital environment Annex B (Normative) Test method for nominal airflow rate Annex C (Normative) Test method for cleaning performance Annex D (Normative) Identification test of air disinfection effect Annex E (Normative) Test method for use of ultraviolet lamps
Referred in QB/T 5217-2018:
*GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
*GB/T 4214.1-2000 Acoustics--Household and similar electrical appliances--Test code for determination of airborne acoustical noise--Part 1:General requirements
*GB 4793.1-2007 Safety requirements for electrical equipment for measurement,control,andlaboratory use-Part 1:General requirements
*GB/T 5080.7-1986 Equipment reliability testing Compliance test plans for failure rate and mean time between failures assuming constant failure rate
*GB 9671-1996 Hygienic standard for hospital waiting room
*GB/T 9969-2008 General Principles for Preparation of Instructions for Use of Industrial Products
*GB/T 14295-2008 Air filters
*GB/T 14710-2009 Environmental requirement and test methods for medical electrical equipment
*GB 15982-2012 Hygienic standard for disinfection in hospitals
*GB/T 18202-2000 Hygienic standard for ozone in indoor air
*GB/T 18204.3-2013 Examination Methods for Public Places - Part 3: Airborne Microorganism
*GB/T 18268.1-2010 Electrical equipment for measurement,control and laboratory use—EMC requirements—Part 1:General requirements
*GBT18801-2016
*JG/T 294-2010 Test of Pollutant Cleaning Performance of Air Cleaner
*WS/T 368-2012 Management specification of air cleaning technique in hospitals
Code of China
Standard
QB/T 5217-2018  Air cleaner for medical environment (English Version)
Standard No.QB/T 5217-2018
Statusvalid
LanguageEnglish
File FormatPDF
Word Count9500 words
Price(USD)230.0
Implemented on2018-7-1
Deliveryvia email in 1 business day
Detail of QB/T 5217-2018
Standard No.
QB/T 5217-2018
English Name
Air cleaner for medical environment
Chinese Name
医用环境空气净化器
Chinese Classification
Professional Classification
QB
ICS Classification
Issued by
Ministry of Industry and Information Technology
Issued on
2018-02-09
Implemented on
2018-7-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
9500 words
Price(USD)
230.0
Keywords
QB/T 5217-2018, QB 5217-2018, QBT 5217-2018, QB/T5217-2018, QB/T 5217, QB/T5217, QB5217-2018, QB 5217, QB5217, QBT5217-2018, QBT 5217, QBT5217
Introduction of QB/T 5217-2018
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by and is under the jurisdiction of the China National Light Industry Council. This standard is issued for the first time. Air cleaner for medical environment 1 Scope This standard specifies the terms and definitions, specification and designation, requirements, test methods, inspection rules, marking, packaging, transportation and storage of air cleaners for medical environment. It is applicable to indoor air cleaners for medical environment and environments with similar cleaning requirements, including: ——cleaners for medical indoor environment, including hospitals, sanatoriums, convalescent hospitals, blood stations and precision instrument rooms; ——cleaners for laboratories, nursing homes, kindergartens, health centers, residential buildings and the like with similar cleaning requirements; ——fresh air ventilators with similar cleaning function can be implemented by reference to this standard. This standard is not applicable to: ——cleaners for hospital clean operating department and specially designed for industrial use; ——cleaners for the special environment and locations of corrosive and explosive gas (such as dust, vapor and gas). Note: See Annex A for Classes II and III hospital environment. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191-2008 Packaging - Pictorial marking for handling of goods GB/T 4214.1-2000 Acoustics - Household and similar electrical appliances - Test code for determination of airborne acoustical noise - Part 1: General requirements GB 4793.1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements GB/T 5080.7-1986 Equipment reliability testing - Compliance test plans for failure rate and mean time between failures assuming constant failure rate GB 9671-1996 Hygienic standard for hospital waiting room GB/T 9969-2008 General principles for preparation of instructions for use of industrial products GB/T 14295-2008 Air filters GB/T 14710-2009 Environmental requirement and test methods for medical electrical equipment GB 15982-2012 Hygienic standard for disinfection in hospitals GB/T 18202-2000 Hygienic standard for ozone in indoor air GB/T 18204.3-2013 Examination methods for public places - Part 3: Airborne microorganism GB/T 18268.1-2010 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements GB/T 18801-2016 Air cleaner JG/T 294-2010 Test of pollutant cleaning performance of air cleaner WS/T 368-2012 Management specification of air cleaning technique in hospitals The Ministry of Health Technical standard for disinfection (Edition 2002) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 air cleaner for medical environment an appliance that has effective removal capability for microorganism, particulate matter and gaseous pollutant in the air and can meet the requirements for medical treatment and similar purposes (hereinafter referred to as "appliance") 3.2 disinfection factor an independent unit used in appliance that can kill natural bacteria in the air and reaches disinfection requirements 3.3 target pollutant specific air pollutant with definite composition Note: It is mainly divided into three categories: particulate matter, gaseous pollutant and microorganism. 3.4 natural decay the reduction of concentration of the target pollutant in the air under specified space and conditions due to non-human factors such as settlement, agglomeration, surface deposition, chemical reaction and air exchange 3.5 total decay the reduction of concentration of the target pollutant in the air under specified space and conditions due to combined action of natural decay and cleaning operation of the appliance 3.6 cleaning efficiency ability of the appliance to remove a certain target pollutant before and after starting up for operation 3.7 one pass cleaning efficiency ratio of the difference between the target pollutant concentration before and after passing through the appliance at one time and the target pollutant concentration before passing through under the rated air volume Note: The value is expressed in %. 3.8 nominal airflow rate the maximum airflow rate at outlet when the appliance is used at rated frequency and rated voltage Note: The value is expressed in m3/h. 3.9 bacterium killing rate ratio of the difference between the bacteria content in the air before the appliance is disinfected (except for naturally extinct bacteria) and the bacteria content in the air at different times during disinfection to the bacteria content in the air before disinfection Note 1: The value is expressed in %. Note 2: Staphylococcus albus is the representative strain in the test. 3.10 natural bacteria extinction rate ratio of the difference between the mean number of natural bacteria in the air before disinfection and that after disinfection to the mean number of natural bacteria in the air before disinfection Note: The value is expressed in %. 3.11 clean air delivery rate; CADR product of one pass cleaning efficiency and nominal airflow rate Note: For the convenience of determination, the clean air delivery rate of air cleaner with nominal airflow rate less than 700m3/h may be obtained in accordance with the decay method specified in GB/T 18801-2015. 4 Specification and designation 4.1 Specification The nominal airflow rate is taken as the rule of designation and basic parameter for the appliance. Note: The value is expressed in m3/h. 4.2 Designation of product model Example: YKJ-A011600B where: YKJ——the medical air cleaner; A01——item 1 of series A; 1600——the nominal airflow rate is 1 600m3/h; B——the second improved design. 5 Requirements 5.1 Appearance 5.1.1 The cleaner shall be upright in shape, clean and smooth in surface, uniform in color and luster, and free from defects such as blisters, cracks, rust and sharp edges as well as obvious scratches and bumps on the surface. 5.1.2 The words, symbols and graphic signs explaining functions on the outer surface shall be marked clearly, accurately and firmly. 5.1.3 Each control device shall be flexible, reliable and free from blockage. Fasteners shall be installed firmly without looseness. 5.2 Nominal airflow rate The measured nominal airflow rate of the appliance shall not be less than 90% of the nominal value.
Contents of QB/T 5217-2018
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Specification and designation 5 Requirements 6 Test methods 7 Inspection rules 8 Marking, packaging, transportation and storage Annex A (Informative) Requirements of Classes II and III hospital environment Annex B (Normative) Test method for nominal airflow rate Annex C (Normative) Test method for cleaning performance Annex D (Normative) Identification test of air disinfection effect Annex E (Normative) Test method for use of ultraviolet lamps
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
QB/T 5217-2018, QB 5217-2018, QBT 5217-2018, QB/T5217-2018, QB/T 5217, QB/T5217, QB5217-2018, QB 5217, QB5217, QBT5217-2018, QBT 5217, QBT5217