2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/SH/T 3007-2007
SH/T 3007-2007   Specification for Design of Tank Farms for Petrochemical Storage (English Version)
Standard No.: SH/T 3007-2007 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8000 words Translation Price(USD):200.0 remind me the price change

Email:

Implemented on:2008-5-1 Delivery: via email in 1 business day

→ → →

,2014-11-1,2008-5-1,14113756081657E6045A8A270B14A
Standard No.: SH/T 3007-2007
English Name: Specification for Design of Tank Farms for Petrochemical Storage
Chinese Name: 石油化工储运系统罐区设计规范
Chinese Classification: P72    Petrochemical and chemical industry engineering
Professional Classification: SH    Professional Standard - Petrochemical
Source Content Issued by: National Development and Reform Commission
Issued on: 2007-11-14
Implemented on: 2008-5-1
Status: superseded
Superseded by:SH/T 3007-2014 Specification for Design of Tank Farms for Petrochemical Storage
Superseded on:2014-11-1
Superseding:SH 3007-1999 Code for the design of tank farms in petrochemical storage and transportation system
Target Language: English
File Format: PDF
Word Count: 8000 words
Translation Price(USD): 200.0
Delivery: via email in 1 business day
1 Scope This Specification specifies the selection of the tanks for the tank farms in the petrochemical storage and transportation system, and the design principles and technical requirements for the normal-pressure, low-pressure and pressure tank farms. This Specification is applicable to the design of the new overground steel tank farms used for storing the liquid materials (including raw material, finished product and auxiliary materials). The expansion and renovation projects can be implemented with reference to this Specification. This Specification is inapplicable to the design of the low-temperature, normal-pressure tank farms for the liquefied hydrocarbon. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this Specification. For dated reference, the subsequent amendments (excluding amending error in the text) to, or modifications of, any of these publications do not apply. However, the parties whose enter into agreement according to this Specification are encouraged to research whether the latest editions of these references are applied or not. For undated references, the latest edition of the normative document is applicable to this Specification. GB 50074 Code for Design of Oil Depot GB 50160 Fire Prevention Code of Petrochemical Enterprise Design SH 3022 Technical Specification for the Coating Anticorrosion of Equipment and Piping in the Petrochemical Industry SH 3063 Specification for the Design of Combustible Gas and Toxic Gas Detection and Alarm for the Petrochemical Industry SH 3074 Steel Pressure Vessels of Petrochemical SH/T 3136 Design Specification for Safety of Liquefied Hydrocarbon Spherical Tanks The State Quality and Technology Supervision Bureau: Technical Supervision Regulations on Safety of the Pressure Vessels 3 General provisions 3.1 The arrangement of the tank farm shall meet the following t principles: a) The position of the tank farm shall be arranged in combination of the flow direction of the liquids; b) The raw material tank farm should be approached to the corresponding processing units; c) The product tank farm should be approached to the loading platform or loading pier; d) The torography should be utilized to realize gravity transfer for the liquids; e) The tanks for the liquids of the similar properties should be arranged together. 3.2 The storage temperature of the flammable liquid shall be determined according to the following principles: a) Higher than the solidifying point (or crystallizing point) of the flammable liquid, but lower than the initial boiling point; b) The mass of the flammable liquid shall be ensured so as to reduce loss; c) The normal transportation of the flammable liquid shall be ensured; d) The settlement and dewatering requirements of the flammable liquids shall be met; e) If the flammable liquid has any additive, then its storage temperature shall meet the special requirements of the additive; f) The relevant heat energy shall be utilized rationally; g) The storage temperature of the stored flammable liquid that needs to be heated shall be lower than the spontaneous ignition temperature hereof; h) As for some liquid chemicals that have special properties, the determined storage temperature shall be able to avoid the generation of autopolymer and oxide. 3.3 The storage temperatures of the flammable liquids may adopt the recommended values from Table 1.
Contents Foreword 1 Scope 2 Normative references 3 General provisions 4 Tank selection 4.1 Tankage 4.2 Tank selection 4.3 Tank quantity 5 Normal-pressure and low-pressure tank farm 5.1 Arrangement of tank 5.2 Selection of tank accessories 5.3 Arrangement and installation of tank accessories 5.4 Arrangement and installation of pipeline 5.5 Selection and installation of instrumentation 5.6 Design principles for liquid heating in the tank 6 Pressure tank farm 6.1 Fundamental rules 6.2 Selection and installation of tank accessories 6.3 Arrangement and installation of pipelines 6.4 Selection and installation of tank meters 6.5 Safety protection of tank 7 Tank anticorrosion and others Wording Explanation
Referred in SH/T 3007-2007:
*GB 50074-2014 Code for design of oil depot
*GB 50160-2008 Fire Prevention Code of Petrochemical Enterprise Design
*SH 3022-1999 Technical specification for the coating anticorrosion of equipment and piping in petrochemical industry
*SH 3063-1999
*SH 3074-1995
Code of China
Standard
SH/T 3007-2007  Specification for Design of Tank Farms for Petrochemical Storage (English Version)
Standard No.SH/T 3007-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count8000 words
Price(USD)200.0
Implemented on2008-5-1
Deliveryvia email in 1 business day
Detail of SH/T 3007-2007
Standard No.
SH/T 3007-2007
English Name
Specification for Design of Tank Farms for Petrochemical Storage
Chinese Name
石油化工储运系统罐区设计规范
Chinese Classification
P72
Professional Classification
SH
ICS Classification
Issued by
National Development and Reform Commission
Issued on
2007-11-14
Implemented on
2008-5-1
Status
superseded
Superseded by
SH/T 3007-2014 Specification for Design of Tank Farms for Petrochemical Storage
Superseded on
2014-11-1
Abolished on
Superseding
SH 3007-1999 Code for the design of tank farms in petrochemical storage and transportation system
Language
English
File Format
PDF
Word Count
8000 words
Price(USD)
200.0
Keywords
SH/T 3007-2007, SH 3007-2007, SHT 3007-2007, SH/T3007-2007, SH/T 3007, SH/T3007, SH3007-2007, SH 3007, SH3007, SHT3007-2007, SHT 3007, SHT3007
Introduction of SH/T 3007-2007
1 Scope This Specification specifies the selection of the tanks for the tank farms in the petrochemical storage and transportation system, and the design principles and technical requirements for the normal-pressure, low-pressure and pressure tank farms. This Specification is applicable to the design of the new overground steel tank farms used for storing the liquid materials (including raw material, finished product and auxiliary materials). The expansion and renovation projects can be implemented with reference to this Specification. This Specification is inapplicable to the design of the low-temperature, normal-pressure tank farms for the liquefied hydrocarbon. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this Specification. For dated reference, the subsequent amendments (excluding amending error in the text) to, or modifications of, any of these publications do not apply. However, the parties whose enter into agreement according to this Specification are encouraged to research whether the latest editions of these references are applied or not. For undated references, the latest edition of the normative document is applicable to this Specification. GB 50074 Code for Design of Oil Depot GB 50160 Fire Prevention Code of Petrochemical Enterprise Design SH 3022 Technical Specification for the Coating Anticorrosion of Equipment and Piping in the Petrochemical Industry SH 3063 Specification for the Design of Combustible Gas and Toxic Gas Detection and Alarm for the Petrochemical Industry SH 3074 Steel Pressure Vessels of Petrochemical SH/T 3136 Design Specification for Safety of Liquefied Hydrocarbon Spherical Tanks The State Quality and Technology Supervision Bureau: Technical Supervision Regulations on Safety of the Pressure Vessels 3 General provisions 3.1 The arrangement of the tank farm shall meet the following t principles: a) The position of the tank farm shall be arranged in combination of the flow direction of the liquids; b) The raw material tank farm should be approached to the corresponding processing units; c) The product tank farm should be approached to the loading platform or loading pier; d) The torography should be utilized to realize gravity transfer for the liquids; e) The tanks for the liquids of the similar properties should be arranged together. 3.2 The storage temperature of the flammable liquid shall be determined according to the following principles: a) Higher than the solidifying point (or crystallizing point) of the flammable liquid, but lower than the initial boiling point; b) The mass of the flammable liquid shall be ensured so as to reduce loss; c) The normal transportation of the flammable liquid shall be ensured; d) The settlement and dewatering requirements of the flammable liquids shall be met; e) If the flammable liquid has any additive, then its storage temperature shall meet the special requirements of the additive; f) The relevant heat energy shall be utilized rationally; g) The storage temperature of the stored flammable liquid that needs to be heated shall be lower than the spontaneous ignition temperature hereof; h) As for some liquid chemicals that have special properties, the determined storage temperature shall be able to avoid the generation of autopolymer and oxide. 3.3 The storage temperatures of the flammable liquids may adopt the recommended values from Table 1.
Contents of SH/T 3007-2007
Contents Foreword 1 Scope 2 Normative references 3 General provisions 4 Tank selection 4.1 Tankage 4.2 Tank selection 4.3 Tank quantity 5 Normal-pressure and low-pressure tank farm 5.1 Arrangement of tank 5.2 Selection of tank accessories 5.3 Arrangement and installation of tank accessories 5.4 Arrangement and installation of pipeline 5.5 Selection and installation of instrumentation 5.6 Design principles for liquid heating in the tank 6 Pressure tank farm 6.1 Fundamental rules 6.2 Selection and installation of tank accessories 6.3 Arrangement and installation of pipelines 6.4 Selection and installation of tank meters 6.5 Safety protection of tank 7 Tank anticorrosion and others Wording Explanation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
SH/T 3007-2007, SH 3007-2007, SHT 3007-2007, SH/T3007-2007, SH/T 3007, SH/T3007, SH3007-2007, SH 3007, SH3007, SHT3007-2007, SHT 3007, SHT3007