2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/TSG ZB002-2008
TSG ZB002-2008   Type Test Rule for Oil and Gas Burners (English Version)
Standard No.: TSG ZB002-2008 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10000 words Translation Price(USD):200.0 remind me the price change

Email:

Implemented on:2008-4-30 Delivery: via email in 1 business day

→ → →

,2021-6-1,2008-4-30,1411376234673709E4A5BFF6E903D
Standard No.: TSG ZB002-2008
English Name: Type Test Rule for Oil and Gas Burners
Chinese Name: 燃油(燃气)燃烧器型式试验规则
Chinese Classification: Q82    Air supply instrument and equipment
Professional Classification: TSG    Special Equipment Safety Specification
Source Content Issued by: AQSIQ
Issued on: 2008-01-08
Implemented on: 2008-4-30
Status: superseded
Superseded by:TSG 11-2020 Regulation on Safety Technology for Boiler
Superseded on:2021-6-1
Target Language: English
File Format: PDF
Word Count: 10000 words
Translation Price(USD): 200.0
Delivery: via email in 1 business day
Article 1 This Rule specifies the contents and items of type test for oil and gas burners (hereinafter referred to as burners) to verfy if the safety and technical performance of burners can meet the requirements of "Safety Technical Regulation for Oil and Gas Burners", and meanwhile provides performance basis for technical assessment of burners. Article 2 This Rule is applicable to burners specified in "Safety Technical Regulation for Oil and Gas Burners", and burners for other purposes may refer to this Rule. Article 3 The main technical requirements of this Rule are quoted from the following specifications and standards: (I) Safety Technical Regulation for Oil and Gas Burners (TSG ZB001-2008); (II) GB 13271-2003 Emission Standard of Air Pollutants for Coal-burning Oil-burning Gas-fired Boiler; (III) GB/T 2888-1991 Methods for Noise Measurement for Fans Blowers Compressors and Roots Blowers; Article 4 Type test (hereinafter referred to as test) must possess certain conditions. Specific test conditions, such as fuel, test environment and system, test boiler, arrangement of test point, test apparatus, excess air coefficient, etc., shall conform to the requirements of Attachment A of this Rule. Article 5 Test for burners includes inspection for compliance with safety technical regulation, safety performance test and operating performance test with the major items are as follows: (I) Basic safety requirements inspection includes structure and design inspection, safety and control devices inspection, and technical document and identification plate inspection, which shall be realized through visual inspection, technical document examination, etc.; (II) Safety performance test includes such items as test, testing and measurement of air tightness (for gas burner), safety time (ignition safety time and extinction safety time), pre-purging time and air volume, ignition thermal power, flame stability, voltage change, thermal resistance, parts surface temperature, etc.; (III) Operating performance test includes the testing of output thermal power scope of burner, combustion products emission under operating state and noise testing, and testing of working curve shall be carried out according to different requirements of boiler or other devices using burner (hereinafter referred to as heating device). The contents and requirements of this safety requirements inspection, safety performance test and operation test are detailed in Attachment B. The error between the working curve provided by the burner manufacturing unit and the measured working curve of test shall be ±5% Article 6 As for the split type burner and the burner with the output thermal power greater than or equal to 4500kW, the test may be carried out on the heating device matched with the burner, but the type, parameter and manufacturing unit of heating device must be described in the test report. Article 7 Test shall be carried out by the type test organization authorized by General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. Type test organization shall carry out the test for burner according to this Rule, and shall make records, provide the test report in time, and give conclusion and comments. Conclusion and comments include conformity and nonconformity of test. For the burner regarded as nonconforming in the test, reasons shall be indicated clearly in test report. For the burner regarded as conforming in the test, test certificate of qualification shall be provided and "TS" marking shall be stuck set by set. See Attachments C and D for the specific format and contents of test report and test certificate of qualification. Article 8 The General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China shall be responsible for the explanation of this Rule. Article 9 This Rule shall be implemented from April 30, 2008.
Type Test Rule for Oil and Gas Burners Attachment A Experimental Conditions and Requirements of Oil and Gas Burners Attachment B Contents and Requirements of Test for Oil and Gas Burners Attachment C Attachment D Type Test Certificate of Qualification of Oil and Gas Burners
Referred in TSG ZB002-2008:
*TSG ZB001-2008 Safety Technical Regulation for Oil and Gas Burners (including Amendment 1)
*GB13271-2003
*GB/T 2888-1991 Methods of noise measurement for fans, blowers compressors and Roots blowers
TSG ZB002-2008 is referred in:
*SH/T 3113-2016 Technical specification for burners of tubular heater in petrochemical industry
Code of China
Standard
TSG ZB002-2008  Type Test Rule for Oil and Gas Burners (English Version)
Standard No.TSG ZB002-2008
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)200.0
Implemented on2008-4-30
Deliveryvia email in 1 business day
Detail of TSG ZB002-2008
Standard No.
TSG ZB002-2008
English Name
Type Test Rule for Oil and Gas Burners
Chinese Name
燃油(燃气)燃烧器型式试验规则
Chinese Classification
Q82
Professional Classification
TSG
ICS Classification
Issued by
AQSIQ
Issued on
2008-01-08
Implemented on
2008-4-30
Status
superseded
Superseded by
TSG 11-2020 Regulation on Safety Technology for Boiler
Superseded on
2021-6-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
200.0
Keywords
TSG ZB002-2008, TSG/T ZB002-2008, TSGT ZB002-2008, TSGZB002-2008, TSG ZB002, TSGZB002, TSG/TZB002-2008, TSG/T ZB002, TSG/TZB002, TSGTZB002-2008, TSGT ZB002, TSGTZB002
Introduction of TSG ZB002-2008
Article 1 This Rule specifies the contents and items of type test for oil and gas burners (hereinafter referred to as burners) to verfy if the safety and technical performance of burners can meet the requirements of "Safety Technical Regulation for Oil and Gas Burners", and meanwhile provides performance basis for technical assessment of burners. Article 2 This Rule is applicable to burners specified in "Safety Technical Regulation for Oil and Gas Burners", and burners for other purposes may refer to this Rule. Article 3 The main technical requirements of this Rule are quoted from the following specifications and standards: (I) Safety Technical Regulation for Oil and Gas Burners (TSG ZB001-2008); (II) GB 13271-2003 Emission Standard of Air Pollutants for Coal-burning Oil-burning Gas-fired Boiler; (III) GB/T 2888-1991 Methods for Noise Measurement for Fans Blowers Compressors and Roots Blowers; Article 4 Type test (hereinafter referred to as test) must possess certain conditions. Specific test conditions, such as fuel, test environment and system, test boiler, arrangement of test point, test apparatus, excess air coefficient, etc., shall conform to the requirements of Attachment A of this Rule. Article 5 Test for burners includes inspection for compliance with safety technical regulation, safety performance test and operating performance test with the major items are as follows: (I) Basic safety requirements inspection includes structure and design inspection, safety and control devices inspection, and technical document and identification plate inspection, which shall be realized through visual inspection, technical document examination, etc.; (II) Safety performance test includes such items as test, testing and measurement of air tightness (for gas burner), safety time (ignition safety time and extinction safety time), pre-purging time and air volume, ignition thermal power, flame stability, voltage change, thermal resistance, parts surface temperature, etc.; (III) Operating performance test includes the testing of output thermal power scope of burner, combustion products emission under operating state and noise testing, and testing of working curve shall be carried out according to different requirements of boiler or other devices using burner (hereinafter referred to as heating device). The contents and requirements of this safety requirements inspection, safety performance test and operation test are detailed in Attachment B. The error between the working curve provided by the burner manufacturing unit and the measured working curve of test shall be ±5% Article 6 As for the split type burner and the burner with the output thermal power greater than or equal to 4500kW, the test may be carried out on the heating device matched with the burner, but the type, parameter and manufacturing unit of heating device must be described in the test report. Article 7 Test shall be carried out by the type test organization authorized by General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China. Type test organization shall carry out the test for burner according to this Rule, and shall make records, provide the test report in time, and give conclusion and comments. Conclusion and comments include conformity and nonconformity of test. For the burner regarded as nonconforming in the test, reasons shall be indicated clearly in test report. For the burner regarded as conforming in the test, test certificate of qualification shall be provided and "TS" marking shall be stuck set by set. See Attachments C and D for the specific format and contents of test report and test certificate of qualification. Article 8 The General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China shall be responsible for the explanation of this Rule. Article 9 This Rule shall be implemented from April 30, 2008.
Contents of TSG ZB002-2008
Type Test Rule for Oil and Gas Burners Attachment A Experimental Conditions and Requirements of Oil and Gas Burners Attachment B Contents and Requirements of Test for Oil and Gas Burners Attachment C Attachment D Type Test Certificate of Qualification of Oil and Gas Burners
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
TSG ZB002-2008, TSG/T ZB002-2008, TSGT ZB002-2008, TSGZB002-2008, TSG ZB002, TSGZB002, TSG/TZB002-2008, TSG/T ZB002, TSG/TZB002, TSGTZB002-2008, TSGT ZB002, TSGTZB002