2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50073-2013
GB 50073-2013   Code for design of clean room (English Version)
Standard No.: GB 50073-2013 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 14000 words Translation Price(USD):130.0 remind me the price change

Email:

Implemented on:2013-9-1 Delivery: via email in 1 business day

→ → →

,,2013-9-1,1411381830187767A75C0D4BB302A
Standard No.: GB 50073-2013
English Name: Code for design of clean room
Chinese Name: 洁净厂房设计规范
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD
Issued on: 2013-01-28
Implemented on: 2013-9-1
Status: valid
Superseding:GB 50073-2001 code for design of clean room
Target Language: English
File Format: PDF
Word Count: 14000 words
Translation Price(USD): 130.0
Delivery: via email in 1 business day
1 General 1.0.1 This code is formulated with view to making the design of clean room to be technologically advanced, economic, reliable, safe and qualified as well as comply with requirements of energy conservation, labor sanitation and environmental protection. 1.0.2 This code is applicable to the design of new-built, extended and rebuilt clean room. 1.0.3 Design of clean room shall the basis of construction installation, maintenance, examination, test and safe operation. 1.0.4 In addition to this code, the design of clean room shall also comply with requirements of relevant current standards. 2 Terms 2.0.1 Clean room The room where the suspended particle concentration in the air is controlled; its construction and application shall be able to reduce the entering, production and retention of particles in the room. Other relevant parameters in the room like temperature, humidity and pressure shall be controlled according to requirements. 2.0.2 Clean zone Restricted zone where the airborne particle concentration in the air is controlled; its construction and application shall be able to reduce the entering, production and retention of particles in the space. Other relevant parameters in the space like temperature, humidity and pressure shall be controlled according to requirements. Clean zone may be open or closed type. 2.0.3 Mobile clean booth Small clean room which may be moved as a whole and may be divided into two types respectively provided with hoarding made of rigid and flexible materials. 2.0.4 Room for cleaning human body The room for cleaning human body according to certain procedure before entering into clean zone. 2.0.5 Room for cleaning material The room for cleaning material according to certain procedure before entering into clean zone. 2.0.6 Particle size The diameter of the globoid which is shown on the adopted particle size tester and equivalent to the response of the tested particle. 2.0.7 Airborne particle Solid or liquid airborne particles (with dimension of 0.1~5μm) in the air used for classification of air cleanliness which are not used to represent the physical property, chemical property, radioactivity and life feature of airborne particles. 2.0.8 Ultrafine particle Particles with equivalent diameter less than 0.1μm. 2.0.9 Microparticle Particles with equivalent diameter greater than 5μm. 2.0.10 Particle size distribution A function of particle size on its frequency distribution and cumulative distribution. 2.0.11 Particle concentration The number of airborne particles in the air per unit volume. 2.0.12 Cleanliness The cleanliness is divided by the number of particles (with particle diameter greater than or equal to a certain value) in the air per unit volume. 2.0.13 Air flow pattern The rational design for flow pattern and distribution of interior air. 2.0.14 Unidirectional airflow The steady and parallel controlled air flow sweeping across the whole section. 2.0.15 Vertical unidirectional airflow The unidirectional airflow perpendicular to horizontal plane. 2.0.16 Horizontal unidirectional airflow The unidirectional airflow parallel to horizontal plane. 2.0.17 Non-unidirectional airflow A distribution pattern of airflow introduced into the clean room (zone) and mixed with the original air in such room or zone. 2.0.18 Mixed airflow The airflow composed of unidirectional airflow and non-unidirectional airflow. 2.0.19 Clean working area The area 0.8~1.5m (except for special process requirements) high from the ground in clean room. 2.0.20 Air shower The booth blowing down and removing adhesive particles on the surface of human body entering clean room by high-speed clean airflow. 2.0.21 Air lock A buffering room arranged at access of clean room for obstructing polluted airflow from outdoors or adjacent room and controlling pressure difference. 2.0.22 Pass box An opening arranged on the partition of the clean room for transmitting materials and tools; it is equipped with casements on each side which may not be opened simultaneously. 2.0.23 Clean bench A bench keeping the required cleanliness in the operation space. 2.0.24 Clean working garment Clean garments with lower particle production to minimize particles produced by workers.
Foreword I 1 General 2 Terms 3 Classification of Air Cleanliness 4 Overall Design 4.1 Location Selection and General Layout of Clean Room 4.2 Process Layout and Design Coordination 4.3 Personnel and Material Cleaning 4.4 Noise Control 4.5 Macrovibration Control 5 Architecture 5.1 General Requirement 5.2 Fire Protection and Evacuation 5.3 Interior Decoration 6 Air Cleaning 6.1 General Requirement 6.2 Pressure Difference Control of Clean Room 6.3 Air Flow Pattern and Air Supply Volume 6.4 Air Cleaning Treatment 6.5 Heating, Ventilation and Smoke Control 6.6 Air Pipe and Accessories 7 Water Supply and Drainage 7.1 General Requirement 7.2 Water Supply 7.3 Drainage 7.4 Fire Water Supply and Fire-fighting Equipment 8 Industrial Pipe 8.1 General Requirement 8.2 Pipe Material and Valve 8.3 Pipe Connection 8.4 Security Technology 9 Electricity 9.1 Power Distribution 9.2 Illumination 9.3 Communication 9.4 Automatic Control 9.5 Electrostatic Protection and Grounding Appendix A Performance Test and Certification of the Clean Room or Clean Zone Appendix B Examples of Fire Hazard Classification for Production Room of Clean Room Appendix C Requirements for Maintenance and Management of Design of Cleaning Air-conditioning System Explanation of Wording in This Code List of Quoted Standards
Referred in GB 50073-2013:
*GB 50016-2014(2018) Code for Fire Protection Design of Buildings - Partial Revision -2018
*GB 50052-2009 Code for Design Electric Power Supply Systems
*GB 50057-2010 Design Code for Protection of Structures against Lightning
*GB 50058-2014 Code for Design of Electrical Installations in Explosive Atmospheres
*GB 50116-2013 Code for design of automatic fire alarm system
*GB 50140-2005 Code for Design of Extinguisher Distribution in Buildings
*GB 50210-2018
*GB 50222-2017 Code for Fire Prevention in Design of Interior Decoration of Buildings
*GB 50316-2000(2008) Design code for industrial metallic piping
*GB 50243-2016 Code of Acceptance for Construction Quality of Ventilation and Air
*GB 50463-2008 Code for design of vibration isolation
*GB/T 8627-2007 Test method for density of smoke from the burning or decomposition of building materials
GB 50073-2013 is referred in:
* GBZ 1-2010 Hygienic Standards for the Design of Industrial Enterprises
* GB 50029-2014 Code for Design of Compressed Air Station
* GB/T 6167-2007 Methods for testing the performance of airborne particle counter
* GB 50030-2013 Oxygen Station Design Specifications
* GB 50187-2012 Code for Design of General Layout of Industrial Enterprises
* GB 50037-2013 Code for design of ground surface and floor of building
*GB 50457-2019 Code for design of pharmaceutical industry clean room
*JG/T 296-2010 Air Shower
*GB/T 41213-2021 Integrated circuit full automatic die bonder
*GB 51377-2019 Design standard for Lithium-ion battery factories
*GB/T 43685-2024 General technical requirements for cabin of inflatable membrane structure and controlled environments
*GB 15979-2024 Hygienic requirements for disposable sanitary products
*T/CEMIA 005-2018 Quartz crucible manufacturing practices for photovoltaic single crystal silicon growth
*GB/T 16275-2025 Urban rail transit lighting
Code of China
Standard
GB 50073-2013  Code for design of clean room (English Version)
Standard No.GB 50073-2013
Statusvalid
LanguageEnglish
File FormatPDF
Word Count14000 words
Price(USD)130.0
Implemented on2013-9-1
Deliveryvia email in 1 business day
Detail of GB 50073-2013
Standard No.
GB 50073-2013
English Name
Code for design of clean room
Chinese Name
洁净厂房设计规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD
Issued on
2013-01-28
Implemented on
2013-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 50073-2001 code for design of clean room
Language
English
File Format
PDF
Word Count
14000 words
Price(USD)
130.0
Keywords
GB 50073-2013, GB/T 50073-2013, GBT 50073-2013, GB50073-2013, GB 50073, GB50073, GB/T50073-2013, GB/T 50073, GB/T50073, GBT50073-2013, GBT 50073, GBT50073
Introduction of GB 50073-2013
1 General 1.0.1 This code is formulated with view to making the design of clean room to be technologically advanced, economic, reliable, safe and qualified as well as comply with requirements of energy conservation, labor sanitation and environmental protection. 1.0.2 This code is applicable to the design of new-built, extended and rebuilt clean room. 1.0.3 Design of clean room shall the basis of construction installation, maintenance, examination, test and safe operation. 1.0.4 In addition to this code, the design of clean room shall also comply with requirements of relevant current standards. 2 Terms 2.0.1 Clean room The room where the suspended particle concentration in the air is controlled; its construction and application shall be able to reduce the entering, production and retention of particles in the room. Other relevant parameters in the room like temperature, humidity and pressure shall be controlled according to requirements. 2.0.2 Clean zone Restricted zone where the airborne particle concentration in the air is controlled; its construction and application shall be able to reduce the entering, production and retention of particles in the space. Other relevant parameters in the space like temperature, humidity and pressure shall be controlled according to requirements. Clean zone may be open or closed type. 2.0.3 Mobile clean booth Small clean room which may be moved as a whole and may be divided into two types respectively provided with hoarding made of rigid and flexible materials. 2.0.4 Room for cleaning human body The room for cleaning human body according to certain procedure before entering into clean zone. 2.0.5 Room for cleaning material The room for cleaning material according to certain procedure before entering into clean zone. 2.0.6 Particle size The diameter of the globoid which is shown on the adopted particle size tester and equivalent to the response of the tested particle. 2.0.7 Airborne particle Solid or liquid airborne particles (with dimension of 0.1~5μm) in the air used for classification of air cleanliness which are not used to represent the physical property, chemical property, radioactivity and life feature of airborne particles. 2.0.8 Ultrafine particle Particles with equivalent diameter less than 0.1μm. 2.0.9 Microparticle Particles with equivalent diameter greater than 5μm. 2.0.10 Particle size distribution A function of particle size on its frequency distribution and cumulative distribution. 2.0.11 Particle concentration The number of airborne particles in the air per unit volume. 2.0.12 Cleanliness The cleanliness is divided by the number of particles (with particle diameter greater than or equal to a certain value) in the air per unit volume. 2.0.13 Air flow pattern The rational design for flow pattern and distribution of interior air. 2.0.14 Unidirectional airflow The steady and parallel controlled air flow sweeping across the whole section. 2.0.15 Vertical unidirectional airflow The unidirectional airflow perpendicular to horizontal plane. 2.0.16 Horizontal unidirectional airflow The unidirectional airflow parallel to horizontal plane. 2.0.17 Non-unidirectional airflow A distribution pattern of airflow introduced into the clean room (zone) and mixed with the original air in such room or zone. 2.0.18 Mixed airflow The airflow composed of unidirectional airflow and non-unidirectional airflow. 2.0.19 Clean working area The area 0.8~1.5m (except for special process requirements) high from the ground in clean room. 2.0.20 Air shower The booth blowing down and removing adhesive particles on the surface of human body entering clean room by high-speed clean airflow. 2.0.21 Air lock A buffering room arranged at access of clean room for obstructing polluted airflow from outdoors or adjacent room and controlling pressure difference. 2.0.22 Pass box An opening arranged on the partition of the clean room for transmitting materials and tools; it is equipped with casements on each side which may not be opened simultaneously. 2.0.23 Clean bench A bench keeping the required cleanliness in the operation space. 2.0.24 Clean working garment Clean garments with lower particle production to minimize particles produced by workers.
Contents of GB 50073-2013
Foreword I 1 General 2 Terms 3 Classification of Air Cleanliness 4 Overall Design 4.1 Location Selection and General Layout of Clean Room 4.2 Process Layout and Design Coordination 4.3 Personnel and Material Cleaning 4.4 Noise Control 4.5 Macrovibration Control 5 Architecture 5.1 General Requirement 5.2 Fire Protection and Evacuation 5.3 Interior Decoration 6 Air Cleaning 6.1 General Requirement 6.2 Pressure Difference Control of Clean Room 6.3 Air Flow Pattern and Air Supply Volume 6.4 Air Cleaning Treatment 6.5 Heating, Ventilation and Smoke Control 6.6 Air Pipe and Accessories 7 Water Supply and Drainage 7.1 General Requirement 7.2 Water Supply 7.3 Drainage 7.4 Fire Water Supply and Fire-fighting Equipment 8 Industrial Pipe 8.1 General Requirement 8.2 Pipe Material and Valve 8.3 Pipe Connection 8.4 Security Technology 9 Electricity 9.1 Power Distribution 9.2 Illumination 9.3 Communication 9.4 Automatic Control 9.5 Electrostatic Protection and Grounding Appendix A Performance Test and Certification of the Clean Room or Clean Zone Appendix B Examples of Fire Hazard Classification for Production Room of Clean Room Appendix C Requirements for Maintenance and Management of Design of Cleaning Air-conditioning System Explanation of Wording in This Code List of Quoted Standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50073-2013, GB/T 50073-2013, GBT 50073-2013, GB50073-2013, GB 50073, GB50073, GB/T50073-2013, GB/T 50073, GB/T50073, GBT50073-2013, GBT 50073, GBT50073