GB 50183-2004   Code for Fire Protection Design of Petroleum and Natural Gas Engin (English Version)
Standard No.: GB 50183-2004 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 26000 words Price(USD):440.0 remind me the price change

Email:

Implemented on:2005-3-1 Delivery: via email in 1 business day
,,
Standard No.: GB 50183-2004
English Name: Code for Fire Protection Design of Petroleum and Natural Gas Engin
Chinese Name: 石油天然气工程设计防火规范
Chinese Classification: P16    Engineering fire protection
Professional Classification: GB    National Standard
ICS Classification: 13.220.20 13.220.20    Fire protection 13.220.20
Issued by: Ministry of Construction
Issued on: 2001-01-01
Implemented on: 2005-3-1
Status: superseded
Superseded by:GB 50183-2015 Standard for urban water conservation evaluation
Superseded on:2016-3-1
Abolished on:2016-03-01
Superseding:GB 50183-1993 Fire prevention code for crude oil and natural gas engineering design
Language: English
File Format: PDF
Word Count: 26000 words
Price(USD): 440.0
Delivery: via email in 1 business day
1.0.1 This Code is formulated for the purposes of following out "prevention first, incorporation of both prevention and elimination" guidelines, standardizing design requirements, prevent and decrease fire losses, guarantee personal and property safety in the petroleum and gas engineering designs. 1.0.2 This Code is applicable to the fire design for newly-built, expanded and reconstructed onshore oil-gas field projects, pipeline station projects, as well as the offshore oil-gas field's land terminal projects. 1.0.3 The fire design of the petroleum and gas projects must be compliant to the relevant guidelines, policies. Combining the practices, it's shall exactly deal with the relation between production and safety, positively adopts state-of-the-art fireproofing and fire-extinguishing technologies, ensure safe production and cost-effectiveness. 1.0.4 Besides the provisions of this Code, the fire design of petroleum and gas projects also must be compliant to the relevant compulsive standards. 2. Terminology 2.1 Terminologies of oil, gas and fire hazard 2.1.1 Oil It refers to crude oil, petroleum products (gasoline, kerosene, diesel oil and naphtha, etc.), stabilized light hydrocarbon and stabilized condensate. 2.1.2 Crude oil It refers to the liquid compound produced from the oil well, giving priority to hydrocarbon. 2.1.3 Natural gas liquid (NGL) It's the generic term of liquid hydrocarbon compounds recovered from the natural gas but not passed through stabilizing treatment, generally including ethane, liquefied petroleum gas (LPG) and stabilized light hydrocarbon. It's also named as mixed light hydrocarbon. 2.1.4 Liquefied petroleum gas (LPG) It's in the gaseous state under normal temperature and pressure but becomes liquid after compression or cooling. It's mainly consisted of propane, butane and their compounds. 2.1.5 Stabilized light hydrocarbon It's abstracted from natural gas liquid (NGL) and is mainly consisted of pentane and other heavier hydrocarbon, the end boiling point shall not be higher than 190℃, under the specified vapor pressure, it allows including a little butane. It's also named as natural gasoline. 2.1.6 Gas condensate It refers to the hydrocarbon liquid abstracted from the condensate gas but not stabilized. 2.1.7 Stabilized gas condensate It's abstracted from the gas condensate and is mainly consisted of pentane and the other heavier hydrocarbon. 2.1.8 Liquefied natural gas (LNG)) It refers to the liquid fluid consisted of methane, together with little ethane, propane, nitrogen and other components. 2.1.9 Boil over It refers to the water-bearing oil that has heat wave characteristics in combustion, such as crude oil, petroleum residue and heavy oil. 2.2 Terminologies of fire-fighting cooling water and fire-extinguishing system 2.2.1 Fixed fire-fighting cooling water system It refers to the fire-fighting cooling water system consisted of fixed fire-water pond (tank), fire pump, fire water supply pipeline and fixed cooling water spray system equipped on the storage tank. 2.2.2 Semi-fixed fire-fighting cooling water system The fixed fire water supply pipeline and hydrants are set up in the tank farm, in case of fire; the water will be pressurized by fire truck or fire pump to spray by the means of water bands and water guns. 2.2.3 Mobile fire-fighting cooling water system No fire water source is set up in the tank farm, in case of fire, the water will be supplied by fire truck or other water sources to spray by the means of onboard water bands and water guns. 2.2.4 Low expansion foam fire-extinguishing system It refers to the foam extinguishing system whose expansion factor is less than 20 times. 2.2.5 Fixed low expansion foam fire-extinguishing system It refers to the low expansion foam fire-extinguishing system consisted of fixed foam fire pump, foam proportioner, foam mixing solution pipeline and the fixed air-foam generator equipped on the storage tank. 2.2.6 Semi-fixed low expansion foam fire-extinguishing system Fixed air-foam generator is set up on the storage tank, in case of fire, the foam truck or motor pump will supply foam mixing solution through hoses. 2.2.7 Mobile low expansion foam fire-extinguishing system In case of fire, the foam truck will provide foam through onboard hoses and foam generators. 2.2.8 Smoke fire-extinguishing system It's consisted of smoke generator, detection and initiating device and the sprayers. In case of fire, it can automatically inject fire-extinguishing smoke to the storage tank. 2.2.9 Dry powder fire-extinguishing system It's consisted of dry powder storage device, actuating device, pipeline, sprayer, fire alarm and interlink control device, it can automatically or manually inject powder extinguishing agents to the protected objects. 2.3 Terminologies of oil gas production facilities 2.3.1 Petroleum and gas station It's a general designation for the station, storage, plant, farm, oil and gas well that can collect, purify, store and transport petroleum and gases. It's called petroleum and gas station or station for short. 2.3.2 Oil station It refers to the stations that have crude oil collection, purifying treatment, storage and transportation functions, or that storage and transportation of natural gasoline and stabilized gas condensate, or that have product oil pipeline transportation functions. 2.3.3 Natural gas station It refers to the station that has natural gas collection, transportation and purifying treatment functions.
1. General Provisions 2. Terminology 2.1 Terminologies of oil, gas and fire hazard 2.2 Terminologies of fire-fighting cooling water and fire-extinguishing system 2.3 Terminologies of oil gas production facilities 3. Basic Provisions 3.1 Classification of fire hazard of petroleum and gas 3.2 Rating of petroleum and gas station 4. Area Arrangement 5. General Plane Arrangement of Petroleum and Gas Station 5.1 General provisions 5.2 Fire break in station 5.3 Road within station 6. Production Facilities at Petroleum and Gas Station 6.1 General provisions 6.2 Petroleum and gas treatment and pressure facilities 6.3 Natural gas treatment and pressure facilities 6.4 Oil-field produced water treatment facilities 6.5 Tank farm 6.6 Tank farms of natural gas liquid and liquefied petroleum gas 6.7 Loading facilities 6.8 Pressure-relief and vent facility 6.9 Constructions 7. Gathering and transportation pipeline in Oil Field 7.1 General provisions 7.2 Gathering and transportation pipeline of crude oil and natural gas liquid 7.3 Gathering and transportation pipeline of natural gas 8. Fire Facilities 8.1 General provisions 8.2 Firehouse 8.3 Fire water supply 8.4 Fire fighting facilities in tank farm 8.5 Fire fighting facilities at natural gas liquid and liquefied petroleum and gas tank farm 8.6 Fire fighting facilities in equipment zone and plant 8.7 Fire fighting facilities of loading and unloading stage 8.8 Fire pump room 8.9 Configuration of fire extinguisher 9. Electric 9.1 Fire power supply and power distribution 9.2 Lightning protection 9.3 Antistatic protection 10 Liquefied Natural Gas Station 10.1 General provisions 10.2 Area arrangement 10.3 Internal arrangement of station 10.4 Fire protection and safety Annex A Examples of Classification of Petroleum and Gas Fire Hazard Annex B Provisions of Beginning Calculation Point of Fire Break Wording Explanation
GB 50183-2004 is referred in:
* GB 50660-2011 Code for Designing large and Middle Fossil Fuel Power Plant
* GB 50974-2014 Code of design on fire protection water supply and hydrant systems
* SY/T 0612-2008 Code for design of gathering and transmission systems in highly hydrogen sulfide gas field
* SY/T 0011-2007 Code for design of natural gas conditioning plant
* SY/T 6881-2012 Design Code for Water Treatment and Reinjection Engineering in Highly Hydrogen Sulfide Gas Field
* GB 50156-2012 Code for design and construction of filling station
* SY/T 6711-2008 Technical Safety Code for Liquefied Natural Gas Receiving Terminal
* GB 50151-2010 Code for design of foam extinguishing systems
* GB 50974-2014 Code of design on fire protection water supply and hydrant systems
* GB 50974-2014 Code of design on fire protection water supply and hydrant systems
* GB 50974-2014 Code of design on fire protection water supply and hydrant systems
* GB 50156-2012 Code for design and construction of filling station
* SY/T 6881-2012 Design Code for Water Treatment and Reinjection Engineering in Highly Hydrogen Sulfide Gas Field
* GB 50660-2011 Code for Designing large and Middle Fossil Fuel Power Plant
* GB 50151-2010 Code for design of foam extinguishing systems
* SY/T 6711-2008 Technical Safety Code for Liquefied Natural Gas Receiving Terminal
* SY/T 0612-2008 Code for design of gathering and transmission systems in highly hydrogen sulfide gas field
* GB 50974-2014 Code of design on fire protection water supply and hydrant systems
* GB 50074-2014 Code for Design of Oil Depot
* DL/T 5174-2003 Code for Design of Gas-Steam Combined-cycle Power Plant
* SY/T 6881-2012 Design Code for Water Treatment and Reinjection Engineering in Highly Hydrogen Sulfide Gas Field
* SY/T 0011-2007 Code for design of natural gas conditioning plant
* SY/T 0090-2006 Code of Instrument Control System Design for Oil-gas Fields and Pipelines
* SY/T 0091-2006 Code for Engineering Design of Computer Control System for Oil/gas Fields and Pipelines
Code of China
Standard
GB 50183-2004  Code for Fire Protection Design of Petroleum and Natural Gas Engin (English Version)
Standard No.GB 50183-2004
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count26000 words
Price(USD)440.0
Implemented on2005-3-1
Deliveryvia email in 1 business day
Detail of GB 50183-2004
Standard No.
GB 50183-2004
English Name
Code for Fire Protection Design of Petroleum and Natural Gas Engin
Chinese Name
石油天然气工程设计防火规范
Chinese Classification
P16
Professional Classification
GB
ICS Classification
Issued by
Ministry of Construction
Issued on
2001-01-01
Implemented on
2005-3-1
Status
superseded
Superseded by
GB 50183-2015 Standard for urban water conservation evaluation
Superseded on
2016-3-1
Abolished on
2016-03-01
Superseding
GB 50183-1993 Fire prevention code for crude oil and natural gas engineering design
Language
English
File Format
PDF
Word Count
26000 words
Price(USD)
440.0
Keywords
GB 50183-2004, GB/T 50183-2004, GBT 50183-2004, GB50183-2004, GB 50183, GB50183, GB/T50183-2004, GB/T 50183, GB/T50183, GBT50183-2004, GBT 50183, GBT50183
Introduction of GB 50183-2004
1.0.1 This Code is formulated for the purposes of following out "prevention first, incorporation of both prevention and elimination" guidelines, standardizing design requirements, prevent and decrease fire losses, guarantee personal and property safety in the petroleum and gas engineering designs. 1.0.2 This Code is applicable to the fire design for newly-built, expanded and reconstructed onshore oil-gas field projects, pipeline station projects, as well as the offshore oil-gas field's land terminal projects. 1.0.3 The fire design of the petroleum and gas projects must be compliant to the relevant guidelines, policies. Combining the practices, it's shall exactly deal with the relation between production and safety, positively adopts state-of-the-art fireproofing and fire-extinguishing technologies, ensure safe production and cost-effectiveness. 1.0.4 Besides the provisions of this Code, the fire design of petroleum and gas projects also must be compliant to the relevant compulsive standards. 2. Terminology 2.1 Terminologies of oil, gas and fire hazard 2.1.1 Oil It refers to crude oil, petroleum products (gasoline, kerosene, diesel oil and naphtha, etc.), stabilized light hydrocarbon and stabilized condensate. 2.1.2 Crude oil It refers to the liquid compound produced from the oil well, giving priority to hydrocarbon. 2.1.3 Natural gas liquid (NGL) It's the generic term of liquid hydrocarbon compounds recovered from the natural gas but not passed through stabilizing treatment, generally including ethane, liquefied petroleum gas (LPG) and stabilized light hydrocarbon. It's also named as mixed light hydrocarbon. 2.1.4 Liquefied petroleum gas (LPG) It's in the gaseous state under normal temperature and pressure but becomes liquid after compression or cooling. It's mainly consisted of propane, butane and their compounds. 2.1.5 Stabilized light hydrocarbon It's abstracted from natural gas liquid (NGL) and is mainly consisted of pentane and other heavier hydrocarbon, the end boiling point shall not be higher than 190℃, under the specified vapor pressure, it allows including a little butane. It's also named as natural gasoline. 2.1.6 Gas condensate It refers to the hydrocarbon liquid abstracted from the condensate gas but not stabilized. 2.1.7 Stabilized gas condensate It's abstracted from the gas condensate and is mainly consisted of pentane and the other heavier hydrocarbon. 2.1.8 Liquefied natural gas (LNG)) It refers to the liquid fluid consisted of methane, together with little ethane, propane, nitrogen and other components. 2.1.9 Boil over It refers to the water-bearing oil that has heat wave characteristics in combustion, such as crude oil, petroleum residue and heavy oil. 2.2 Terminologies of fire-fighting cooling water and fire-extinguishing system 2.2.1 Fixed fire-fighting cooling water system It refers to the fire-fighting cooling water system consisted of fixed fire-water pond (tank), fire pump, fire water supply pipeline and fixed cooling water spray system equipped on the storage tank. 2.2.2 Semi-fixed fire-fighting cooling water system The fixed fire water supply pipeline and hydrants are set up in the tank farm, in case of fire; the water will be pressurized by fire truck or fire pump to spray by the means of water bands and water guns. 2.2.3 Mobile fire-fighting cooling water system No fire water source is set up in the tank farm, in case of fire, the water will be supplied by fire truck or other water sources to spray by the means of onboard water bands and water guns. 2.2.4 Low expansion foam fire-extinguishing system It refers to the foam extinguishing system whose expansion factor is less than 20 times. 2.2.5 Fixed low expansion foam fire-extinguishing system It refers to the low expansion foam fire-extinguishing system consisted of fixed foam fire pump, foam proportioner, foam mixing solution pipeline and the fixed air-foam generator equipped on the storage tank. 2.2.6 Semi-fixed low expansion foam fire-extinguishing system Fixed air-foam generator is set up on the storage tank, in case of fire, the foam truck or motor pump will supply foam mixing solution through hoses. 2.2.7 Mobile low expansion foam fire-extinguishing system In case of fire, the foam truck will provide foam through onboard hoses and foam generators. 2.2.8 Smoke fire-extinguishing system It's consisted of smoke generator, detection and initiating device and the sprayers. In case of fire, it can automatically inject fire-extinguishing smoke to the storage tank. 2.2.9 Dry powder fire-extinguishing system It's consisted of dry powder storage device, actuating device, pipeline, sprayer, fire alarm and interlink control device, it can automatically or manually inject powder extinguishing agents to the protected objects. 2.3 Terminologies of oil gas production facilities 2.3.1 Petroleum and gas station It's a general designation for the station, storage, plant, farm, oil and gas well that can collect, purify, store and transport petroleum and gases. It's called petroleum and gas station or station for short. 2.3.2 Oil station It refers to the stations that have crude oil collection, purifying treatment, storage and transportation functions, or that storage and transportation of natural gasoline and stabilized gas condensate, or that have product oil pipeline transportation functions. 2.3.3 Natural gas station It refers to the station that has natural gas collection, transportation and purifying treatment functions.
Contents of GB 50183-2004
1. General Provisions 2. Terminology 2.1 Terminologies of oil, gas and fire hazard 2.2 Terminologies of fire-fighting cooling water and fire-extinguishing system 2.3 Terminologies of oil gas production facilities 3. Basic Provisions 3.1 Classification of fire hazard of petroleum and gas 3.2 Rating of petroleum and gas station 4. Area Arrangement 5. General Plane Arrangement of Petroleum and Gas Station 5.1 General provisions 5.2 Fire break in station 5.3 Road within station 6. Production Facilities at Petroleum and Gas Station 6.1 General provisions 6.2 Petroleum and gas treatment and pressure facilities 6.3 Natural gas treatment and pressure facilities 6.4 Oil-field produced water treatment facilities 6.5 Tank farm 6.6 Tank farms of natural gas liquid and liquefied petroleum gas 6.7 Loading facilities 6.8 Pressure-relief and vent facility 6.9 Constructions 7. Gathering and transportation pipeline in Oil Field 7.1 General provisions 7.2 Gathering and transportation pipeline of crude oil and natural gas liquid 7.3 Gathering and transportation pipeline of natural gas 8. Fire Facilities 8.1 General provisions 8.2 Firehouse 8.3 Fire water supply 8.4 Fire fighting facilities in tank farm 8.5 Fire fighting facilities at natural gas liquid and liquefied petroleum and gas tank farm 8.6 Fire fighting facilities in equipment zone and plant 8.7 Fire fighting facilities of loading and unloading stage 8.8 Fire pump room 8.9 Configuration of fire extinguisher 9. Electric 9.1 Fire power supply and power distribution 9.2 Lightning protection 9.3 Antistatic protection 10 Liquefied Natural Gas Station 10.1 General provisions 10.2 Area arrangement 10.3 Internal arrangement of station 10.4 Fire protection and safety Annex A Examples of Classification of Petroleum and Gas Fire Hazard Annex B Provisions of Beginning Calculation Point of Fire Break Wording Explanation