2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50763-2012
GB 50763-2012   Codes for accessibility design (English Version)
Standard No.: GB 50763-2012 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 15000 words Translation Price(USD):140.0 remind me the price change

Email:

Implemented on:2012-9-1 Delivery: via email in 1 business day

→ → →

,,2012-9-1,14113818192114B766FC473BA3E4D
Standard No.: GB 50763-2012
English Name: Codes for accessibility design
Chinese Name: 无障碍设计规范
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD; AQSIQ
Issued on: 2012-3-30
Implemented on: 2012-9-1
Status: valid
Superseding:JGJ 50-2001 Codes for Design on Accessibility of Urban Roads and Buildings
Target Language: English
File Format: PDF
Word Count: 15000 words
Translation Price(USD): 140.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code was formulated with a view to creating a accessibility environment in cities, improving life quality of people and ensuring people in needs to safely and conveniently use facilities. 1.0.2 This code is applicable to constructed, renovated and extended urban road, urban square, urban green space, residential district, residential building and historic building throughout the country. Those urban road, urban square, urban green space, building or design with accessibility needs, not involved in this code should be implemented according to requirements of similar types in this code. Accessibility for rural road and public service facility should be implemented according to this code. 1.0.3 Accessibility design for relevant railway, aviation, urban rail transit and water transportation facility shall meet the requirements of this code and those for relevant accessibility design in relevant industry. 1.0.4 During the implementation of this code, urban accessibility design still shall comply with relevant principles and policies of China and meet overall urban development requirements so as to achieve safety and usability, advanced technology and economic rationality. 1.0.5 Urban accessibility design shall not only meet those specified in this code, but also those specified in current relevant national standard. 2 Terms 2.0.1 Curb ramp It is a kind of ramp located at sidewalk intersection or on both ends of crosswalk to avoid sidewalk curb from causing traffic obstacles and make pedestrian conveniently accessible to sidewalk. 2.0.2 Tactile ground surface indicator It is a kind of solid floor tile paved on sidewalk or at other locations to render people with visual disability a tactile sense and guide people with visual disability to go ahead and distinguish direction so as to arrive at path of destination. 2.0.3 Directional indicator It is a tactile ground surface indicator with strip surface that guides people with visual disability directly go ahead through tactile cane and foot sense. 2.0.4 Warning indicator It refers to tactile ground surface indicator with dot-like surface, which is used at starting point, corner, end point of tactile ground surface indicator to indicate positions of service facilities and warn people with visual disability of unsafe or dangerous conditions ahead and serves as a warning role. 2.0.5 Accessible entrance It refers to entrance whose gradient, width, height, ground material and handrail are convenient for people with movement disorder to pass through. 2.0.6 Ramp entrance It refers to entrance not equipped with handrail, with its ground gradient no less than 1: 20. 2.0.7 Wheelchair turning space It refers to space arranged to make people riding a wheelchair convenient to change direction through turning. 2.0.8 Wheelchair ramp It refers to ramp whose gradient, width, height, ground material and handrail are convenient for people riding a wheelchair to pass through.
Foreword I 1 General Provisions 2 Terms 3 Design Requirements of Accessible Facilities 3.1 Curb Ramp 3.2 Tactile Ground Surface Indicator 3.3 Accessible Entrance 3.4 Wheelchair Ramp 3.5 Accessible Routes and Doors 3.6 Accessible Stairway and Steps 3.7 Wheelchair Accessible Elevator, Platform Lift and Stair Lift 3.8 Handrails 3.9 Public Toilet and Individual Washroom for Wheelchair Users 3.10 Public Bathroom 3.11 Accessible Guest Room 3.12 Accessible Housing and Dormitory 3.13 Wheelchair Accessible Seat 3.14 Accessible Vehicle Parking Lot 3.15 Low Height Service Facilities 3.16 Accessibility Sign Identification System and Information Accessibility 4 Urban Road 4.1 Implementation Scope 4.2 Sidewalk 4.3 Crosswalk 4.4 Pedestrian Overpass and Underpass 4.5 Bus Stop 4.6 Accessibility Sign Identification System 5 Urban Square 5.1 Implementation Scope 5.2 Design Requirements 6 Urban Green Space 6.1 Implementation Scope 6.2 Park Green Space 6.3 Affiliated Green Space 6.4 Other Green Space 7 Residential District, Residential Building 7.1 Road 7.2 Residential Green Space 7.3 Auxiliary Public Facilities 7.4 Residential Building 8 Public Buildings 8.1 General Requirements 8.2 Office, Scientific Research and Judicial Buildings 8.3 Education Building 8.4 Medical Rehabilitation Building 8.5 Welfare and Special Service Building 8.6 Sports Building 8.7 Culture Building 8.8 Commercial Service Building 8.9 Passenger Coach Station 8.10 Public Parking Space (Garage) 8.11 Oil and Gas Fuelling Stations 8.12 Buildings in Expressway Service Area 8.13 Public Toilet 9 Accessibility Construction And Renovation Of Historic Buildings 9.1 Implementation Scope 9.2 Accessible Travel Path 9.3 Entrance 9.4 Courtyard 9.5 Service Facilities 9.6 Information and Sign Appendix A Accessibility Sign Appendix B Signboard of Accessible Facilities Appendix C Directional Signboard of Accessible Facilities Explanation of Wording in This Code List of Quoted Standards
Referred in GB 50763-2012:
*JGJ 76-2019
GB 50763-2012 is referred in:
* JGJ 62-2014 Code for Design of Hotel Building
* GB 51039-2014 Code for design of general hospital
* JGJ 312-2013 Code for Electrical Design of Medical Buildings
* GB 50037-2013 Code for design of ground surface and floor of building
* GB 50157-2013 Code for Design of Metro
* CECS 158-2015 Technical specification for membrane structures
* JGJ 66-2015
*GB/T 18973-2016 Classification and evaluation of tourism toilets
*JGJ 57-2016 Code for Design of Theater Building
*JGJ 36-2016 Code for design of dormitory building
*JGJ 64-2017 Standard for design of dietetic buildings
*GB 50867-2013 Design code for buildings of elderly facilities
*GB 50352-2019 Unified standard for design of civil building
*DBJ/T 15-83-2017 Assessment standard for green building in Guangdong Province
*GB/T 34419-2017 Configuration requirements for multi-sports public playground in city communities
*JGJ/T 67-2019 Standard for design of office building
*GB/T 18973-2022 Quality requirements and evaluation of tourism toilets
Code of China
Standard
GB 50763-2012  Codes for accessibility design (English Version)
Standard No.GB 50763-2012
Statusvalid
LanguageEnglish
File FormatPDF
Word Count15000 words
Price(USD)140.0
Implemented on2012-9-1
Deliveryvia email in 1 business day
Detail of GB 50763-2012
Standard No.
GB 50763-2012
English Name
Codes for accessibility design
Chinese Name
无障碍设计规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD; AQSIQ
Issued on
2012-3-30
Implemented on
2012-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JGJ 50-2001 Codes for Design on Accessibility of Urban Roads and Buildings
Language
English
File Format
PDF
Word Count
15000 words
Price(USD)
140.0
Keywords
GB 50763-2012, GB/T 50763-2012, GBT 50763-2012, GB50763-2012, GB 50763, GB50763, GB/T50763-2012, GB/T 50763, GB/T50763, GBT50763-2012, GBT 50763, GBT50763
Introduction of GB 50763-2012
1 General Provisions 1.0.1 This code was formulated with a view to creating a accessibility environment in cities, improving life quality of people and ensuring people in needs to safely and conveniently use facilities. 1.0.2 This code is applicable to constructed, renovated and extended urban road, urban square, urban green space, residential district, residential building and historic building throughout the country. Those urban road, urban square, urban green space, building or design with accessibility needs, not involved in this code should be implemented according to requirements of similar types in this code. Accessibility for rural road and public service facility should be implemented according to this code. 1.0.3 Accessibility design for relevant railway, aviation, urban rail transit and water transportation facility shall meet the requirements of this code and those for relevant accessibility design in relevant industry. 1.0.4 During the implementation of this code, urban accessibility design still shall comply with relevant principles and policies of China and meet overall urban development requirements so as to achieve safety and usability, advanced technology and economic rationality. 1.0.5 Urban accessibility design shall not only meet those specified in this code, but also those specified in current relevant national standard. 2 Terms 2.0.1 Curb ramp It is a kind of ramp located at sidewalk intersection or on both ends of crosswalk to avoid sidewalk curb from causing traffic obstacles and make pedestrian conveniently accessible to sidewalk. 2.0.2 Tactile ground surface indicator It is a kind of solid floor tile paved on sidewalk or at other locations to render people with visual disability a tactile sense and guide people with visual disability to go ahead and distinguish direction so as to arrive at path of destination. 2.0.3 Directional indicator It is a tactile ground surface indicator with strip surface that guides people with visual disability directly go ahead through tactile cane and foot sense. 2.0.4 Warning indicator It refers to tactile ground surface indicator with dot-like surface, which is used at starting point, corner, end point of tactile ground surface indicator to indicate positions of service facilities and warn people with visual disability of unsafe or dangerous conditions ahead and serves as a warning role. 2.0.5 Accessible entrance It refers to entrance whose gradient, width, height, ground material and handrail are convenient for people with movement disorder to pass through. 2.0.6 Ramp entrance It refers to entrance not equipped with handrail, with its ground gradient no less than 1: 20. 2.0.7 Wheelchair turning space It refers to space arranged to make people riding a wheelchair convenient to change direction through turning. 2.0.8 Wheelchair ramp It refers to ramp whose gradient, width, height, ground material and handrail are convenient for people riding a wheelchair to pass through.
Contents of GB 50763-2012
Foreword I 1 General Provisions 2 Terms 3 Design Requirements of Accessible Facilities 3.1 Curb Ramp 3.2 Tactile Ground Surface Indicator 3.3 Accessible Entrance 3.4 Wheelchair Ramp 3.5 Accessible Routes and Doors 3.6 Accessible Stairway and Steps 3.7 Wheelchair Accessible Elevator, Platform Lift and Stair Lift 3.8 Handrails 3.9 Public Toilet and Individual Washroom for Wheelchair Users 3.10 Public Bathroom 3.11 Accessible Guest Room 3.12 Accessible Housing and Dormitory 3.13 Wheelchair Accessible Seat 3.14 Accessible Vehicle Parking Lot 3.15 Low Height Service Facilities 3.16 Accessibility Sign Identification System and Information Accessibility 4 Urban Road 4.1 Implementation Scope 4.2 Sidewalk 4.3 Crosswalk 4.4 Pedestrian Overpass and Underpass 4.5 Bus Stop 4.6 Accessibility Sign Identification System 5 Urban Square 5.1 Implementation Scope 5.2 Design Requirements 6 Urban Green Space 6.1 Implementation Scope 6.2 Park Green Space 6.3 Affiliated Green Space 6.4 Other Green Space 7 Residential District, Residential Building 7.1 Road 7.2 Residential Green Space 7.3 Auxiliary Public Facilities 7.4 Residential Building 8 Public Buildings 8.1 General Requirements 8.2 Office, Scientific Research and Judicial Buildings 8.3 Education Building 8.4 Medical Rehabilitation Building 8.5 Welfare and Special Service Building 8.6 Sports Building 8.7 Culture Building 8.8 Commercial Service Building 8.9 Passenger Coach Station 8.10 Public Parking Space (Garage) 8.11 Oil and Gas Fuelling Stations 8.12 Buildings in Expressway Service Area 8.13 Public Toilet 9 Accessibility Construction And Renovation Of Historic Buildings 9.1 Implementation Scope 9.2 Accessible Travel Path 9.3 Entrance 9.4 Courtyard 9.5 Service Facilities 9.6 Information and Sign Appendix A Accessibility Sign Appendix B Signboard of Accessible Facilities Appendix C Directional Signboard of Accessible Facilities Explanation of Wording in This Code List of Quoted Standards