2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/HJ/T 92-2002
HJ/T 92-2002   Technical requirements for monitoring of total amount of pollutants in waste water (English Version)
Standard No.: HJ/T 92-2002 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):250.0 remind me the price change

Email:

Implemented on:2003-1-1 Delivery: via email in 1 business day

→ → →

,,2003-1-1,14113738808670BA05B27505DDC71
Standard No.: HJ/T 92-2002
English Name: Technical requirements for monitoring of total amount of pollutants in waste water
Chinese Name: 水污染物排放总量监测技术规范
Chinese Classification: Z60    Pollutants discharge in general
Professional Classification: HJ    Professional Standard - Environment
Issued on: 2002-12-25
Implemented on: 2003-1-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 250.0
Delivery: via email in 1 business day
1 Scope This specification is applicable to the monitoring of total amount of pollutants in waste water discharged by enterprises and institutions, as well as the monitoring of total amount of pollutants in waste water discharged during the "three simultaneities" completion acceptance of construction projects, from municipal sewage outlets and during the implementation of sewage permit system. 2 Normative references The provisions contained in the following standards and specifications, which are referenced in this specification, constitute the provisions of this specification and have the same effect as this specification. GB 12997-91 Water quality - Technical regulation on the design of sampling programmes GB 12998-91 Water quality - Guidance on sampling techniques GB 15562.1-1995 Graphical signs for environmental protection - Discharge outlet (source) GB 8978-1996 Integrated wastewater discharge standard HJ/T 15-1996 Supersonic flowmeter of wastewater HJ/T 91-2002 Technical specifications requirements for monitoring of surface water and waste water CJ/T 3008.1~5-93 Standards for municipal wastewater discharge measurement CJ/T 3017-93 Submersible electromagnetic flowmeter ISO 555-1: 1973 Liquid flow measurement in open channels - Dilution methods for measurement of steady flow - Part 1: Constant-rate injection method ISO 555-2: 1987 Liquid flow measurement in open channels - Dilution methods for the measurement of steady flow - Part 2: Integration method ISO 555-3: 1987 Liquid flow measurement in open channels - Dilution methods for the measurement of steady flow - Part 3: Constant-rate integration method and radiotracer integration method ISO 748: 1979 Liquid flow measurement in open channels - Velocity-area methods ISO 1070: 1973 Hydrometry - Slope-area method ISO 4359: 1983 Liquid flow measurement in open channels - Rectangular, trapezoidal and -shaped flumes ISO 4360: 1984 Liquid flow measurement in open channels by weirs and flumes - Triangular profile weirs ISO 4377: 1982 Liquid flow measurement in open channels - Flat-V weirs If the above standards and specifications are revised, the latest version shall prevail. 3 Definitions 3.1 instantaneous water sample samples collected randomly (such as time, flow and place) from water 3.2 mixed water sample 3.2.1 proportional mixed water samples mixed water samples with water sample amount being proportional to time or flow at the same sampling point within a certain period of time 3.2.2 mixed water samples with equal time interval mixed water samples with equal volume collected in equal time interval at the same sampling point within a certain period of time 3.3 proportional sampler a kind of special automatic water quality sampler, through which the amount of collected water samples is proportional to time and flow, so that the pollutant concentration of the mixed water samples collected at any time period reflects the average concentration in that time period 3.4 automatic sampling continuous or discontinuous sampling carried out by instruments and equipment according to preset procedures in the sampling process
Foreword ii 1 Scope 2 Normative references 3 Definitions 4 Formulation of monitoring scheme 5 Sampling point 6 Monitoring of sampling 7 Flow measurement 8 Monitoring items and analysis methods 9 Quality assurance 10 Total amount verification
Referred in HJ/T 92-2002:
*GB 12997-1991 Water quility-Techmical regulation on the design of sampling programmes
*GB 12998-1991 Water quility-Guidance on sampling techniques
*GB 15562.1-1995 Graphical signs for environmental protection - Discharge outlet (source)
*GB 8978-1996 Integrated Wastewater Discharge Standard
*HJ/T 15-1996
*HJ/T 91-2002 Technical specifications requirements for monitoring of surface water and waste water
*CJ/T 3008.1-1993 Standards for municipal wastewater discharge measurement -- triangular notch (V notch) thin -- plate weir
*CJ/T 3008.2-1993 Standards for municipal wastewater discharge measurement -- rectangular notch thin -- plate weir
*CJ/T 3008.3-1993 Standards for municipal wastewater discharge measurement -- parshall flume
*CJ/T 3008.4-1993 Standards for municipal wastewater discharge measurement -- broad -- crested weir
*CJ/T 3008.5-1993 Standards for municipal wastewater discharge measurement -- triangular -- profile weir
*CJ/T 3017-1993 Submersible electromagnetic flowmeter
HJ/T 92-2002 is referred in:
*SH/T 3024-2017 Design Specification for Environmental Protection in Petrochemical Industry
*GB/T 39361-2020 Discharge requirements for cooling seawater
*HJ/T 373-2007 Technical specifications of quality assurance and quality control for monitoring of stationary pollution source(on trial)
Code of China
Standard
HJ/T 92-2002  Technical requirements for monitoring of total amount of pollutants in waste water (English Version)
Standard No.HJ/T 92-2002
Statusvalid
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)250.0
Implemented on2003-1-1
Deliveryvia email in 1 business day
Detail of HJ/T 92-2002
Standard No.
HJ/T 92-2002
English Name
Technical requirements for monitoring of total amount of pollutants in waste water
Chinese Name
水污染物排放总量监测技术规范
Chinese Classification
Z60
Professional Classification
HJ
ICS Classification
Issued by
Issued on
2002-12-25
Implemented on
2003-1-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
250.0
Keywords
HJ/T 92-2002, HJ 92-2002, HJT 92-2002, HJ/T92-2002, HJ/T 92, HJ/T92, HJ92-2002, HJ 92, HJ92, HJT92-2002, HJT 92, HJT92
Introduction of HJ/T 92-2002
1 Scope This specification is applicable to the monitoring of total amount of pollutants in waste water discharged by enterprises and institutions, as well as the monitoring of total amount of pollutants in waste water discharged during the "three simultaneities" completion acceptance of construction projects, from municipal sewage outlets and during the implementation of sewage permit system. 2 Normative references The provisions contained in the following standards and specifications, which are referenced in this specification, constitute the provisions of this specification and have the same effect as this specification. GB 12997-91 Water quality - Technical regulation on the design of sampling programmes GB 12998-91 Water quality - Guidance on sampling techniques GB 15562.1-1995 Graphical signs for environmental protection - Discharge outlet (source) GB 8978-1996 Integrated wastewater discharge standard HJ/T 15-1996 Supersonic flowmeter of wastewater HJ/T 91-2002 Technical specifications requirements for monitoring of surface water and waste water CJ/T 3008.1~5-93 Standards for municipal wastewater discharge measurement CJ/T 3017-93 Submersible electromagnetic flowmeter ISO 555-1: 1973 Liquid flow measurement in open channels - Dilution methods for measurement of steady flow - Part 1: Constant-rate injection method ISO 555-2: 1987 Liquid flow measurement in open channels - Dilution methods for the measurement of steady flow - Part 2: Integration method ISO 555-3: 1987 Liquid flow measurement in open channels - Dilution methods for the measurement of steady flow - Part 3: Constant-rate integration method and radiotracer integration method ISO 748: 1979 Liquid flow measurement in open channels - Velocity-area methods ISO 1070: 1973 Hydrometry - Slope-area method ISO 4359: 1983 Liquid flow measurement in open channels - Rectangular, trapezoidal and -shaped flumes ISO 4360: 1984 Liquid flow measurement in open channels by weirs and flumes - Triangular profile weirs ISO 4377: 1982 Liquid flow measurement in open channels - Flat-V weirs If the above standards and specifications are revised, the latest version shall prevail. 3 Definitions 3.1 instantaneous water sample samples collected randomly (such as time, flow and place) from water 3.2 mixed water sample 3.2.1 proportional mixed water samples mixed water samples with water sample amount being proportional to time or flow at the same sampling point within a certain period of time 3.2.2 mixed water samples with equal time interval mixed water samples with equal volume collected in equal time interval at the same sampling point within a certain period of time 3.3 proportional sampler a kind of special automatic water quality sampler, through which the amount of collected water samples is proportional to time and flow, so that the pollutant concentration of the mixed water samples collected at any time period reflects the average concentration in that time period 3.4 automatic sampling continuous or discontinuous sampling carried out by instruments and equipment according to preset procedures in the sampling process
Contents of HJ/T 92-2002
Foreword ii 1 Scope 2 Normative references 3 Definitions 4 Formulation of monitoring scheme 5 Sampling point 6 Monitoring of sampling 7 Flow measurement 8 Monitoring items and analysis methods 9 Quality assurance 10 Total amount verification
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
HJ/T 92-2002, HJ 92-2002, HJT 92-2002, HJ/T92-2002, HJ/T 92, HJ/T92, HJ92-2002, HJ 92, HJ92, HJT92-2002, HJT 92, HJT92