2025-12-5 216.73.216.21
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5009.8-2016
GB 5009.8-2016   National Food Safety Standard--Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods (English Version)
Standard No.: GB 5009.8-2016 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):80.0 remind me the price change

Email:

Implemented on:2017-6-23 Delivery: via email in 1 business day

→ → →

,2024-9-6,2017-6-23,14863927829800002f7de44728b9dbd6
Standard No.: GB 5009.8-2016
English Name: National Food Safety Standard--Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods
Chinese Name: 食品安全国家标准 食品中果糖、葡萄糖、蔗糖、麦芽糖、乳糖的测定
Professional Classification: GB    National Standard
Source Content Issued by: National Health and Family Planning Commission; China Food and Drug Administration
Issued on: 2016-12-23
Implemented on: 2017-6-23
Status: superseded
Superseded by:GB 5009.8-2023 National food safety standard - Determination of fructose, glucose, sucrose, maltose and lactose in foods
Superseded on:2024-9-6
Superseding:GB/T 5009.8-2008 Determination of saccharose in foods
GB/T 18932.22-2003 Method for the determination of fructose,glucose,sucrose,maltose contents in honey - Liquid chromatography refractive index detection method
GB/T 22221-2008 Determination of fructose glucose sucrose maltose lactose in foods—High-performance liquid chromatography
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 80.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB/T 5009.8-2008 Determination of Saccharose in Foods, GB/T 18932.22-2003 Method for the Determination of Fructose, Glucose, Sucrose, Maltose Contents in Honey - Liquid Chromatography Refractive Index Detection Method, and GB/T 22221-2008 Determination of Fructose, Glucose, Sucrose, Maltose, Lactose in Foods - High-Performance Liquid Chromatography. The following main changes have been made with respect to GB/T 5009.8-2008: ——the standard name is revised as "食品安全国家标准 食品中果糖、葡萄糖、蔗糖、麦芽糖、乳糖的测定 (National Food Safety Standard Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods)"; ——the pretreatment of partial samples is added. National Food Safety Standard Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods 1 Scope This standard specifies the determination methods of fructose, glucose, sucrose, maltose and lactose in foods. In this standard, Method I is applicable to the determination of fructose, glucose, sucrose, maltose and lactose in foods, and Method II is applicable to the determination of sucrose in foods. "Method I" - high performance liquid chromatography is applicable to the determination of fructose, glucose, sucrose, maltose and lactose in such foods as cereals, milk products, fruit and vegetable products, bee honey, syrup and beverage. "Method II" - acid hydrolysis - Lane-Eynon's method is applicable to the determination of sucrose in foods. Method I High Performance Liquid Chromatography 2 Theory After extraction, the fructose, glucose, sucrose, maltose and lactose in the specimen are separated with the high performance liquid chromatography column, and detected with refractive index detector or evaporative light-scattering detector, and subjected to quantitation by external standard method. 3 Reagents and Materials Unless otherwise specified, analytically pure reagents and Grade 1 water (specified in GB/T 6682) are adopted for the purposes of this method. 3.1 Reagents 3.1.1 Acetonitrile: chromatographically pure. 3.1.2 Zinc acetate [Zn(CH3COO)2·2H2O]. 3.1.3 Potassium ferrocyanide {K4[Fe(CN)6]·3H2O}. 3.1.4 Petroleum ether: boiling range of 30℃~60℃. 3.2 Preparation of reagents 3.2.1 Zinc acetate solution: weigh 21.9g of zinc acetate, add 3mL of glacial acetic acid, dissolve them with water and dilute the solution to 100mL. 3.2.2 Potassium ferricyanide solution: weigh 10.6g of potassium ferricyanide, dissolve it with water and dilute the solution to 100mL. 3.3 Standards 3.3.1 Fructose (C6H12O6, CAS No.: 57-48-7) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.2 Glucose (C6H12O6, CAS No.: 50-99-7) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.3 Sucrose (C12H22O11, CAS No.: 57-50-1) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.4 Maltose (C12H22O11, CAS No.: 69-79-4) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.5 Lactose (C6H12O6, CAS No.: 63-42-3) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.4 Preparation of standard solutions 3.4.1 Standard stock solution of sugar (20mg/mL): separately weigh 1g of the above-mentioned fructose, glucose, sucrose, maltose and lactose which have been dried for 2h at 96℃±2℃, add water and scale the volume to 50mL, put in a place at 4℃ and seal, and they can be stored for a month. 3.4.2 Standard application solution of sugar: separately pipet 1.00mL, 2.00mL, 3.00mL and 5.00mL of standard stock solution of sugar into a 10mL volumetric flask, add water and scale the volume, and they are equivalent to standard solutions with concentration of 2.0mg/mL, 4.0mg/mL, 6.0mg/mL and 10.0mg/mL. 4 Apparatuses 4.1 Balance: with a sensibility of 0.1mg 4.2 Ultrasonic vibrator 4.3 Magnetic stirrer 4.4 Centrifuge: rotating speed ≥4,000r/min 4.5 High performance liquid chromatograph: with refractive index detector or evaporative light-scattering detector. 4.6 Liquid chromatographic column: amido-chromatographic column with length of 250mm, inner diameter of 4.6mm, film thickness of 5μm, or chromatographic column with equivalent performance. 5 Specimen Preparation and Preservation 5.1 Specimen preparation 5.1.1 Solid sample Weigh at least 200g of representative sample, pulverize with a grinder, sieve through a 2.0mm round hole screen, mix uniformly, put it into a clean container, seal and mark. 5.1.2 Semi-solid and liquid samples (except for bee honey sample) Weigh at least 200g (mL) of representative sample, mix sufficiently, put it into a clean container, seal and mark. 5.1.3 Bee honey sample Stir the uncrystallized sample uniformly with effort; as for the sample with separated crystal, plug the cap of the sample container, put the sample container into water bath (not exceeding 60℃), wait until the sample is dissolved completed, mix well, and rapidly cool to room temperature for subsequent inspection. During dissolving, it shall avoid the water content entering. 5.2 Preservation Such specimen which deteriorates easily as bee honey is preserved at 0℃~4℃. 6 Analytical Procedures 6.1 Sample treatment 6.1.1 Foods with fat content less than 10% Weigh 0.5g~10g (to the nearest 0.001g) of pulverized or uniformly-mixed specimen (weigh 10g if sugar content ≤5%; weigh 5g if sugar content is 5%~10%; weigh 2g if sugar content is 10%~40%; and weigh 0.5g if sugar content ≥40%) into a 100mL volumetric flask, add about 50mL of water to dissolve it, add 5mL of zinc acetate solution and 5mL of potassium ferricyanide solution slowly, add water to the scale, carry out magnetic stirring or ultrasonic vibration for 30min, filter with dry filter paper, discard the primary filtrate, then filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.1.2 Syrup and bee honey Weigh 1g~2g (to the nearest 0.001g) of uniformly-mixed specimen into a 50mL volumetric flask, add water and scale the volume to 50mL, sufficiently shake well, filter with dry filter paper, discard the primary filtrate, filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.1.3 Beverage containing carbon dioxide Pipet uniformly-mixed specimen into the evaporating dish, stir on the water bath (slightly heat) to remove carbon dioxide, pipet 50.0mL into a 100mL volumetric flask, respectively add 5mL of zinc acetate solution and potassium ferricyanide solution slowly, dilute with water to the scale, shake well, leave standstill for 30min, filter with dry filter paper, discard primary filtrate, and filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.1.4 Foods with fat content greater than 10% Weigh 5g~10g (to the nearest 0.001g) of pulverized or uniformly-mixed specimen into a 100mL centrifuge tube (with plug), add 50mL of petroleum ether, mix uniformly, exhaust the air, shake for 2min, carry out centrifugation at 1,800 r/min for 15min, and repeat the above-mentioned procedures after removing the petroleum ether until most of the fat is removed. Evaporate the residual petroleum ether, pound the sample with a glass rod, transfer it into a 100mL volumetric flask, rinse the centrifuge tube twice with 50mL of water, add the washing liquid into a 100mL volumetric flask, add 5mL of zinc acetate solution and 5mL of potassium ferricyanide solution slowly, add water to the scale, carry out magnetic stirring or ultrasonic vibration for 30min, filter with filter paper, discard the primary filtrate and filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.2 Reference conditions for chromatograph The chromatographic conditions shall meet the requirement that the resolution of fructose, glucose, sucrose, maltose and lactose is greater than 1.5. See Figures A.1 and A.2 in Annex A for chromatograms. a) Mobile phase: acetonitrile + water = 70+30 (volume ratio); b) Flow rate of mobile phase: 1.0mL/min; c) Column temperature: 40℃; d) Injection volume: 20μL; e) Condition of refractive index detector: 40℃; f) Condition of evaporative light-scattering detector: temperature of drift tube: 80℃~90℃; nitrogen pressure: 350kPa; striker: closed. 6.3 Plotting of standard curve Determine the standard application solution of sugar according to the above-mentioned recommended chromatographic condition, record the peak area or peak height of chromatogram, take the peak area or peak height as longitudinal coordinate and concentration of standard working solution as horizontal ordinate, and linear equation is adopted for refractive index detector; power function equation is adopted for evaporative light-scattering detector to plot the standard curve.
Foreword I 1 Scope 2 Theory 3 Reagents and Materials 4 Apparatuses 5 Specimen Preparation and Preservation 6 Analytical Procedures 7 Expression of Analysis Results 8 Precision 9 Others 10 Theory 11 Reagents and Solutions 12 Apparatuses 13 Specimen Preparation and Preservation 14 Analytical Procedures 15 Expression of Analysis Results 16 Precision 17 Others Annex A Chromatograms
Referred in GB 5009.8-2016:
*GB 5009.6-2016 National Food Safety Standard — Determination of Fat in Foods
*GB 5009.5-2016 National Food Safety Standard — Determination of Protein in Foods
*GB/T 7735-2016/XG1-2021 Automated eddy current testing of seamless and welded (except submerged arc-welded) steel tubes for detection of imperfections,includes Amendment 1
*GB/T 33014.4-2016 Road vehicles―Component test methods for electrical/electronic disturbances from narrowband radiated electromagnetic energy―Part 4:Bulk current injection (BCI)
*GB/T 33014.1-2016 Road vehicles―Component test methods for electrical/electronic disturbances from narrowband radiated electromagnetic energy―Part 1:General
*GB/T 10288-2016/XG1-2020 Test method for down and feather,includes Amendment 1
*GB/T 17685-2016 Down and feather
*GB 19147-2016/XG1-2018 Automobile diesel fuels, includes Amendment 1
*GB 5009.265-2016 National Food Safety Standard-Determination of Polycyclic Aromatic Hydrocarbons in Foods
*GB/T 33339-2016 Vanadium flow battery system-Test method
*GB 25280-2016 Road traffic signal controller
*GB 4789.34-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Bifidobacterium
*GB 5009.267-2016 National Food Safety Standard Determination of Iodine in Foods
*GB 4789.6-2016 National food safety standard -Microbiological examination of food-Examination of diarrheogenic Escherichia coli
*GB 4789.4-2016 National food safety standard -Microbiological examination of food-Examination of salmonella
*GB 4789.3-2016 National Food Safety Standard-Food Microbiological Examination—Enumeration of Coliforms
*GB 4789.2-2016 National food safety standard -Microbiological examination of food: Aerobic plate count
*GB 4789.1-2016 National Food Safety Standard—Food Microbiological Examination—General
*GB 4789.12-2016 National Food Safety Standard—Food Microbiological Examination—Clostridium Botulinum and Botulinum Toxin
*GB 4789.10-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Staphylococcus Aureus
*GB 4789.35-2016 National food safety standard -Microbiological examination of food-Examination of lactic acid bacteria
GB 5009.8-2016 is referred in:
*GB 5009.92-2016 National Food Safety Standard-Determination of Calcium in Foods
*GB 5009.124-2016 National Food Safety Standard-Determination of Amino Acid in Foods
*GB 5009.154-2016 National food safety standard-Determination of vitamin B6 in foods
*GB 5009.158-2016 National Food Safety Standard Determination of Vitamin K1 in Foods
*GB 5009.168-2016 National Food Safety Standard —Determination of Fatty Acid in Foods
*GB 5009.263-2016 National Food Safety Standard--Determination of Aspartame and Alitame in Foods
*GB 5009.90-2016 National Food Safety Standard-Determination of Iron in Foods
*GB 5009.89-2016 National Food Safety Standard--Determination of Niacin and Nicotinamide in Foods
*GB 5009.87-2016 National Food Safety Standard Determination of Phosphorus in Foods
*GB 5009.85-2016 National Food Safety Standard-Determination of Vitamin B2 in Foods
*GB 5009.83-2016 National Food Safety Standard Determination of Carotene in Foods
*GB 5009.82-2016 National Food Safety Standard -- Determination of Vitamins A, D and E in Foods
*GB 5009.33-2016 National food safety standard-Determination of nitrite and nitrate in foods
*GB 5009.24-2016 National Food Safety Standard — Determination of M Aflatoxins in Foods
*GB 5009.22-2016 National Food Safety Standard--Determination of B-group and G-group Aflatoxins in Foods
*GB/T 13667.4-2013 Steel Book Shelves - Part 4: Electric Dense Bookshelf
*GB/T 30366-2013 Terminology Related to Biomass
*GB/T 30420.1-2013 Sewing Machine Terminology - Part 1: Basic Terminology
*GB/T 5169.44-2013 Fire Hazard Testing for Electric and Electronic Products - Part 44: Guidance for Assessing the Fire Hazard - Fire Hazard Assessment
*GB/Z 23751.3-2013 Micro fuel-cell power generation system - Part 3: Interchangeability of fuel vessels
*GB/T 6519-2013 Ultrasonic inspection of wrought aluminium and magnesium alloy products
*GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100V - Part 17: Particular requirements and tests for switch mode power supply un
*GB 826-1989 key for original document of administration
*GB 11945-1989 Autoclaved lime-sand brick
*GB 10783-1989 Food additive - Chilli orange
*GB 10963-1989 Circuit-breakers for household and similar installations
*GB/T 9770-1988 Steel cord conveyor belts
*GB 10252-1988 Regulations for radiation protection of 60Co irradiation processing facility
*GB 4706.19-1988 Safety of household and similar electrical appliances --Particular requirements for liquid heaters
Code of China
Standard
GB 5009.8-2016  National Food Safety Standard--Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods (English Version)
Standard No.GB 5009.8-2016
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)80.0
Implemented on2017-6-23
Deliveryvia email in 1 business day
Detail of GB 5009.8-2016
Standard No.
GB 5009.8-2016
English Name
National Food Safety Standard--Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods
Chinese Name
食品安全国家标准 食品中果糖、葡萄糖、蔗糖、麦芽糖、乳糖的测定
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
National Health and Family Planning Commission; China Food and Drug Administration
Issued on
2016-12-23
Implemented on
2017-6-23
Status
superseded
Superseded by
GB 5009.8-2023 National food safety standard - Determination of fructose, glucose, sucrose, maltose and lactose in foods
Superseded on
2024-9-6
Abolished on
Superseding
GB/T 5009.8-2008 Determination of saccharose in foods
GB/T 18932.22-2003 Method for the determination of fructose,glucose,sucrose,maltose contents in honey - Liquid chromatography refractive index detection method
GB/T 22221-2008 Determination of fructose glucose sucrose maltose lactose in foods—High-performance liquid chromatography
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
80.0
Keywords
GB 5009.8-2016, GB/T 5009.8-2016, GBT 5009.8-2016, GB5009.8-2016, GB 5009.8, GB5009.8, GB/T5009.8-2016, GB/T 5009.8, GB/T5009.8, GBT5009.8-2016, GBT 5009.8, GBT5009.8
Introduction of GB 5009.8-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB/T 5009.8-2008 Determination of Saccharose in Foods, GB/T 18932.22-2003 Method for the Determination of Fructose, Glucose, Sucrose, Maltose Contents in Honey - Liquid Chromatography Refractive Index Detection Method, and GB/T 22221-2008 Determination of Fructose, Glucose, Sucrose, Maltose, Lactose in Foods - High-Performance Liquid Chromatography. The following main changes have been made with respect to GB/T 5009.8-2008: ——the standard name is revised as "食品安全国家标准 食品中果糖、葡萄糖、蔗糖、麦芽糖、乳糖的测定 (National Food Safety Standard Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods)"; ——the pretreatment of partial samples is added. National Food Safety Standard Determination of Fructose, Glucose, Sucrose, Maltose and Lactose in Foods 1 Scope This standard specifies the determination methods of fructose, glucose, sucrose, maltose and lactose in foods. In this standard, Method I is applicable to the determination of fructose, glucose, sucrose, maltose and lactose in foods, and Method II is applicable to the determination of sucrose in foods. "Method I" - high performance liquid chromatography is applicable to the determination of fructose, glucose, sucrose, maltose and lactose in such foods as cereals, milk products, fruit and vegetable products, bee honey, syrup and beverage. "Method II" - acid hydrolysis - Lane-Eynon's method is applicable to the determination of sucrose in foods. Method I High Performance Liquid Chromatography 2 Theory After extraction, the fructose, glucose, sucrose, maltose and lactose in the specimen are separated with the high performance liquid chromatography column, and detected with refractive index detector or evaporative light-scattering detector, and subjected to quantitation by external standard method. 3 Reagents and Materials Unless otherwise specified, analytically pure reagents and Grade 1 water (specified in GB/T 6682) are adopted for the purposes of this method. 3.1 Reagents 3.1.1 Acetonitrile: chromatographically pure. 3.1.2 Zinc acetate [Zn(CH3COO)2·2H2O]. 3.1.3 Potassium ferrocyanide {K4[Fe(CN)6]·3H2O}. 3.1.4 Petroleum ether: boiling range of 30℃~60℃. 3.2 Preparation of reagents 3.2.1 Zinc acetate solution: weigh 21.9g of zinc acetate, add 3mL of glacial acetic acid, dissolve them with water and dilute the solution to 100mL. 3.2.2 Potassium ferricyanide solution: weigh 10.6g of potassium ferricyanide, dissolve it with water and dilute the solution to 100mL. 3.3 Standards 3.3.1 Fructose (C6H12O6, CAS No.: 57-48-7) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.2 Glucose (C6H12O6, CAS No.: 50-99-7) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.3 Sucrose (C12H22O11, CAS No.: 57-50-1) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.4 Maltose (C12H22O11, CAS No.: 69-79-4) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.3.5 Lactose (C6H12O6, CAS No.: 63-42-3) with the purity of 99%, or reference material approved and awarded with reference material certificate by the nation. 3.4 Preparation of standard solutions 3.4.1 Standard stock solution of sugar (20mg/mL): separately weigh 1g of the above-mentioned fructose, glucose, sucrose, maltose and lactose which have been dried for 2h at 96℃±2℃, add water and scale the volume to 50mL, put in a place at 4℃ and seal, and they can be stored for a month. 3.4.2 Standard application solution of sugar: separately pipet 1.00mL, 2.00mL, 3.00mL and 5.00mL of standard stock solution of sugar into a 10mL volumetric flask, add water and scale the volume, and they are equivalent to standard solutions with concentration of 2.0mg/mL, 4.0mg/mL, 6.0mg/mL and 10.0mg/mL. 4 Apparatuses 4.1 Balance: with a sensibility of 0.1mg 4.2 Ultrasonic vibrator 4.3 Magnetic stirrer 4.4 Centrifuge: rotating speed ≥4,000r/min 4.5 High performance liquid chromatograph: with refractive index detector or evaporative light-scattering detector. 4.6 Liquid chromatographic column: amido-chromatographic column with length of 250mm, inner diameter of 4.6mm, film thickness of 5μm, or chromatographic column with equivalent performance. 5 Specimen Preparation and Preservation 5.1 Specimen preparation 5.1.1 Solid sample Weigh at least 200g of representative sample, pulverize with a grinder, sieve through a 2.0mm round hole screen, mix uniformly, put it into a clean container, seal and mark. 5.1.2 Semi-solid and liquid samples (except for bee honey sample) Weigh at least 200g (mL) of representative sample, mix sufficiently, put it into a clean container, seal and mark. 5.1.3 Bee honey sample Stir the uncrystallized sample uniformly with effort; as for the sample with separated crystal, plug the cap of the sample container, put the sample container into water bath (not exceeding 60℃), wait until the sample is dissolved completed, mix well, and rapidly cool to room temperature for subsequent inspection. During dissolving, it shall avoid the water content entering. 5.2 Preservation Such specimen which deteriorates easily as bee honey is preserved at 0℃~4℃. 6 Analytical Procedures 6.1 Sample treatment 6.1.1 Foods with fat content less than 10% Weigh 0.5g~10g (to the nearest 0.001g) of pulverized or uniformly-mixed specimen (weigh 10g if sugar content ≤5%; weigh 5g if sugar content is 5%~10%; weigh 2g if sugar content is 10%~40%; and weigh 0.5g if sugar content ≥40%) into a 100mL volumetric flask, add about 50mL of water to dissolve it, add 5mL of zinc acetate solution and 5mL of potassium ferricyanide solution slowly, add water to the scale, carry out magnetic stirring or ultrasonic vibration for 30min, filter with dry filter paper, discard the primary filtrate, then filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.1.2 Syrup and bee honey Weigh 1g~2g (to the nearest 0.001g) of uniformly-mixed specimen into a 50mL volumetric flask, add water and scale the volume to 50mL, sufficiently shake well, filter with dry filter paper, discard the primary filtrate, filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.1.3 Beverage containing carbon dioxide Pipet uniformly-mixed specimen into the evaporating dish, stir on the water bath (slightly heat) to remove carbon dioxide, pipet 50.0mL into a 100mL volumetric flask, respectively add 5mL of zinc acetate solution and potassium ferricyanide solution slowly, dilute with water to the scale, shake well, leave standstill for 30min, filter with dry filter paper, discard primary filtrate, and filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.1.4 Foods with fat content greater than 10% Weigh 5g~10g (to the nearest 0.001g) of pulverized or uniformly-mixed specimen into a 100mL centrifuge tube (with plug), add 50mL of petroleum ether, mix uniformly, exhaust the air, shake for 2min, carry out centrifugation at 1,800 r/min for 15min, and repeat the above-mentioned procedures after removing the petroleum ether until most of the fat is removed. Evaporate the residual petroleum ether, pound the sample with a glass rod, transfer it into a 100mL volumetric flask, rinse the centrifuge tube twice with 50mL of water, add the washing liquid into a 100mL volumetric flask, add 5mL of zinc acetate solution and 5mL of potassium ferricyanide solution slowly, add water to the scale, carry out magnetic stirring or ultrasonic vibration for 30min, filter with filter paper, discard the primary filtrate and filter the subsequent filtrate through 0.45μm microfiltration membrane or filter the supernatant obtained by centrifugation through 0.45μm microfiltration membrane into the sample container for liquid chromatographic analysis. 6.2 Reference conditions for chromatograph The chromatographic conditions shall meet the requirement that the resolution of fructose, glucose, sucrose, maltose and lactose is greater than 1.5. See Figures A.1 and A.2 in Annex A for chromatograms. a) Mobile phase: acetonitrile + water = 70+30 (volume ratio); b) Flow rate of mobile phase: 1.0mL/min; c) Column temperature: 40℃; d) Injection volume: 20μL; e) Condition of refractive index detector: 40℃; f) Condition of evaporative light-scattering detector: temperature of drift tube: 80℃~90℃; nitrogen pressure: 350kPa; striker: closed. 6.3 Plotting of standard curve Determine the standard application solution of sugar according to the above-mentioned recommended chromatographic condition, record the peak area or peak height of chromatogram, take the peak area or peak height as longitudinal coordinate and concentration of standard working solution as horizontal ordinate, and linear equation is adopted for refractive index detector; power function equation is adopted for evaporative light-scattering detector to plot the standard curve.
Contents of GB 5009.8-2016
Foreword I 1 Scope 2 Theory 3 Reagents and Materials 4 Apparatuses 5 Specimen Preparation and Preservation 6 Analytical Procedures 7 Expression of Analysis Results 8 Precision 9 Others 10 Theory 11 Reagents and Solutions 12 Apparatuses 13 Specimen Preparation and Preservation 14 Analytical Procedures 15 Expression of Analysis Results 16 Precision 17 Others Annex A Chromatograms
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5009.8-2016, GB/T 5009.8-2016, GBT 5009.8-2016, GB5009.8-2016, GB 5009.8, GB5009.8, GB/T5009.8-2016, GB/T 5009.8, GB/T5009.8, GBT5009.8-2016, GBT 5009.8, GBT5009.8